Records from 2016 to 2026. Most recent: inspection, 16 February 2026.
Inspection history · 19
16 February 2026
Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8312550
19 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8081526
7 February 2024
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7861905
3 March 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7645061
31 October 2022
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7586772
21 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7415853
26 March 2021
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7163388
15 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7156499
10 February 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6906202
7 February 2019
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6621708
10 January 2018
Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6335621
2 November 2017
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6300004
21 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6127585
11 January 2017
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6069504
11 October 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6020242
25 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5952707
21 July 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5948165
28 April 2016
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5864861
22 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5860202
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 February 2024
Resolved
At each inspection for certification, the marine inspector may require that a man overboard drill be held under simulated emergency conditions specified by the inspector. Because the vessel has a COI endorsement to operate with a "Master Only" for operations lasting no greater than twelve (12) hours, a man overboard drill must be conducted where the master must recover a test dummy unassisted. The initial man overboard drill that was conducted on February 12, 2024, was failed and the vessel was issued a deficiency that required the vessel to operate with a full crew complement (01 MASTER and 01 DECKHAND) until USCG Inspectors witnessed a successful man overboard drill where the master recovers the test dummy unassisted. On February 22, 2024, when USCG Inspectors were onboard to witness a second attempt at performing a man overboard recovery drill using only the master, the master failed to recover the test dummy and stated that he did not have the proper equipment onboard to perform the recovery (boat hook). The vessel is prohibited from operating with a "Master Only", as endorsed on its COI, and must operate with full crew of (01 MASTER and 01 DECKHAND) until a successful man overboard drill is witnessed by USCG Inspectors.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 February 2024
Resolution: Attended vessel and found crew of 01 Master and 01 Deckhand to be onboard. Vessel is still prohibited from "Master Only" operations until Deficiency #6 is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2024
Resolved
Electrical equipment in spaces containing fuel tanks for gasoline must be part of an intrinsically safe system. Some coverings on electrical connections were damaged or missing. Ensure all electrical connections are properly covered and intrinsically safe.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 February 2024
Resolution: Received photo evidence that the electrical connections are properly covered and intrinsically safe.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 February 2024
Resolved
Drill entries shall be made recording the date of the drill and general description. The vessel's log recording drills was missing. Replace log.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2024
Resolved 1 April 2024
Resolution: New log provided with multiple drills conducted and recorded.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 February 2024
Resolved
A vessel must carry a first aid kit approved by 46 CFR 160.041 or equivalent. First aid kit did not have proper approval. Place proper first aid kit onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2024
Resolved 1 April 2024
Resolution: Approved First Aid kit onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2024
Resolved
Remote fuel shut off valves must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Label fuel shut off valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2024
Resolved 1 April 2024
Resolution: Sticker updated.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 12 February 2024
Resolved
The construction and arrangement of a vessel must give consideration to provisions of a seaworthy hull. Recent maintenance caused open wire/piping penetration holes to remain open between aft engineering space and fuel space. Close or plug unused openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2024
Resolved 1 April 2024
Resolution: Verified complete
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 February 2024
Resolved
At each inspection for certification, the marine inspector may require that a man overboard drill be held under simulated emergency conditions specified by the inspector. Because the vessel has a COI endorsement to operate with a "Master Only" for operations lasting no greater than twelve (12) hours, a man overboard drill was conducted where the master was supposed to recover a test dummy unassisted. The master was unable to recover the test dummy unassisted, but was able to complete the recovery with the assistance of the deckhand onboard. The vessel is prohibited from operating with a "Master Only", as endorsed on its COI, until a successful man overboard drill is witnessed by the attending USCG marine inspector under the operating conditions of "Master Only" (i.e. the master must make recovery unassisted).
Action required: 705 - Other - as specified
Resolved 1 April 2024
Resolution: Satisfactory drill witnessed, videoed and saved to unit file.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 February 2024
Resolved
Vessel must have a valid station license. Station license expired on February 6, 2024, and the new station license has not been received in the mail. Place new station license onboard vessel upon receipt.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2024
Resolved 1 April 2024
Resolution: New one onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2023
Resolved
A space containing fuel tanks for gasoline must have a ventilation system that complies with 46 CFR 182.460. Blowers for mechanical ventilation blowers were not operating. Repair blowers. Also, blower shutdown from installed firefighting system must be tested in presence of a USCG Marine Inspector after blowers are repaired prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2023
Resolution: Blowers are operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2023
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems, it must meet SAE J-1942. Flexible non-metallic hose must be complete with factory-assembled end fittings on the hose or field attachable type fittings may be used. All hose end fittings must comply with SAE J-1475. If field attachable type fittings are used, they must be hydro-statically tested to twice the operating pressure of the system. Newly-installed fuel hoses are not J-1942 and are not attached with J-1475 fittings. Replace hoses with proper fittings prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2023
Resolution: Hoses replaced with proper hoses/fittings
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2023
Resolved
The general construction of the vessel must be such as to minimize fire hazards. Fuel piping from unused fuel tank is open-ended and not disconnected from tank. Isolate and disconnect all piping associated with unused fuel tank and ensure fuel tank is isolated prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2023
Resolution: Piping re-connected and tank place back into service.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 3 March 2023
Resolved
Each vessel must have a stability letter issued by the Coast Guard that sets forth conditions of operation. Current stability letter, issued 03 February 2014, states that no weights shall be added, removed, altered and/or relocated without authorization of cognizant [name withheld] installed vessel engines and decommissioning of forward fuel tank result in weight changes to the vessel. Either a new stability proof test must be conducted and new stability letter is issued by cognizant OCMI, or owner must prove that the new engines are equal in weight to the previous engines and the weight change of the empty fuel tank must be mitigated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2023
Resolution: Fuel tank placed back into service and new engines were proven to result in no change to weight.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2023
Resolved
The construction and arrangement of a vessel must give consideration to provisions of a seaworthy hull. Recent maintenance caused open wire/piping penetration holes to remain open between outboard well deck, aft engineering space, and fuel tank space. Close or plug unused openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 24 March 2023
Resolution: Penetration holes repaired
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 and the owner must provide satisfactory evidence of required servicing to the marine inspector. Inspection of firefighting equipment is due.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 24 March 2023
Resolution: Inspection was completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2023
Resolved
Vessel must have at least three 2.5 gallon buckets with lanyard attached, labeled FIRE BUCKET. Vessel had only two fire buckets onboard. Place a third fire bucket onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 24 March 2023
Resolution: Third bucket placed aboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2023
Resolved
Cable and wiring must be supported with metal supports spaced not more than 24 inches apart and cable splicing must be insulated or protected. Wiring supports inadequate on back deck and machinery spaces and back deck wire splice was open and uninsulated. Repair and properly support wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 24 March 2023
Resolution: Supports installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2023
Resolved
Vessels under 65' carrying less than 50 passengers need an hand bilge pump. Pump was missing. Place serviceable hand pump onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 24 March 2023
Resolution: Hand pump aboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2023
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life buoy. Mark life buoy with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 24 March 2023
Resolution: Lifebuoy labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 March 2021
Resolved
Each ring life buoy must be fitted with a lifeline of at least 60 feet in length. Attached lifeline is too short. Install lifeline of at least 60 feet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 26 March 2021
Resolution: New lifeline installed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 15 March 2021
Resolved
Vessel must comply with applicable requirements issued by the FCC as set forth in 47 CFR 80. Vessel does not have a valid FCC Safety Radio Certificate. Obtain valid certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 26 March 2021
Resolution: New Radio Certificate Issued.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2020
Resolved
A flammable vapor detection sensor must be located at the lowest part of a space containing a fuel tank. Repair or replace faulty vapor detection sensor and prove operation to the satisfaction of attending Marine Inspector prior to carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2020
Resolved 13 February 2020
Resolution: Installed new sensor and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 February 2020
Resolved
Vessel must provide evidence of annual fire fighting servicing for all fixed fire extinguishing systems. Provide proof of annual servicing for the fixed fire fighting system prior to carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2020
Resolved 13 February 2020
Resolution: Annual service completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 February 2019
Resolved
A vessel must be provided with individual bilge lines and bilge suctions for each watertight compartment. Repair or replace bilge pump in aft compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 13 March 2019
Resolution: Vessel installed new bilge pump, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 February 2019
Resolved
Vessel must have a means of accurately determining the amount of fuel in each tank by either a sounding pipe or installed marine type fuel gauge. Install a means to determine the fuel level.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 13 March 2019
Resolution: Vessel installed new level sending units on all fuel tanks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2019
Resolved
Each battery used in lifesaving equipment must be replaced at the annual inspection. Replace battery in life ring buoy light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 13 March 2019
Resolution: New battery installed in RLB floating light.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 February 2019
Resolved
The number of life jackets must be marked on containers used to store life jackets. Mark life jacket storage container with proper number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 13 March 2019
Resolution: New markings completed.
Fire Fighting › Ventilation Systems › Fans
Issued 10 January 2018
Resolved
Starboard exhaust fan inoperational. Repair or replace.
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 18 January 2018
Resolution: Repaired blower.
Engineering › Bilge Water Management System › Pump
Issued 10 January 2018
Resolved
Submersible electric bilge pumps do not meet the requirements of UL 1113. Replace with approved bilge pumps.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Replaced pumps through boat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 January 2018
Resolved
Markings on Ring Life Buoy are faded and need to be remarked.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Re-stenciled markings.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 January 2018
Resolved
Ring life buoy floating light battery is expired and needs replaced. Replace and mark battery with installation date.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Replaced battery and stenciled date on battery.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 January 2018
Resolved
First aid kit is missing (25) aspirin. Replace as original.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Replaced First Aid Kit.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 January 2018
Resolved
Vessel equiped with only one of required two portable electric light. Obtain required second light.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Two working portable lights onboard.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 November 2017
Resolved
No passenger permitted until a dry dock is completed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 3 November 2017
Resolution: Completed dry dock exam, SAT.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 July 2016
Resolved
Shaun Simoneaux and [name withheld] shall not operate in a 'master only' condition until satisfactorily conducting a Man-Overboard Drill in a reduced crew ('Master-Only') condition in the presence of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 11 August 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 April 2016
Resolved
Replenish expired items in First Aid kit. 46 CFR 184.710
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 23 May 2016
Resolution: Items replenished
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 April 2016
Resolved
POST OPERATING INSTRUCTIONS NEAR MANUAL OPERATION STATION FOR FIXED FIREFIGHTING SYS., LABEL FIXED FIREFIGHTING SYSTEM PULL STOP SO IT CAN NOT BE MISTAKEN FOR ENGINE FUEL STOPS. 46 CFR 181.420, 46 CFR 185.612
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 23 May 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 April 2016
Resolved
REPLACE ELECTRICAL SWITCH AND RECEPTACLE BENEATH OPERATOR WINDOW WITH PROPER MARINE (SEALED) OUTLET BOX AND COVER. 46 CFR 183.210
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 31 May 2016
Resolution: Repaired
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 April 2016
Resolved
TWO WORKING FLASHLIGHTS ARE REQUIRED TO BE ONBOARD. 46 CFR 183.430
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 23 May 2016
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 April 2016
Resolved
GASOLINE FUME DETECTOR IS NOT OPERATIONAL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 28 April 2016
Resolution: DETECTOR REPLACED, SYSTEM IS OPERATIONAL.
Lifesaving › Hand Flares › Expired
Issued 28 April 2016
Resolved
ALL FLARES ARE EXPIRED. NO NIGHT OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 28 April 2016
Resolution: FLARES REPLACED- ON-THE-SPOT CORRECTION.