Records from 2014 to 2026. Most recent: inspection, 21 May 2026.
Documentation record
Registered dimensions (L × B × D)390.1 ft × 74.0 ft × 26.5 ft
Registered tonnagegross 6,763 / net 6,763
ITC dimensions (L × B × D)390.1 ft × 74.0 ft × 26.5 ft
ITC tonnagegross 7,306 / net 4,935
BuilderSENESCO MARINE · KINGSTOWN, RI, UNITED STATES · built 2014
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6763 - Regulatory (Subpart C or D), Gross Ton
7306 - Convention (Subpart B), Gross Ton
6763 - Regulatory (Subpart C or D), Net Ton
4935 - Convention (Subpart B), Net Ton
13980 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
21 May 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8377646
2 February 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8304705
10 July 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8170174
25 March 2024
Hull Examination · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7865859
11 October 2023
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7806476
12 August 2022
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7530514
16 November 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7352505
13 October 2021
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7331602
15 June 2021
Periodic Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7226086
3 August 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7023729
6 February 2020
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6905923
8 January 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6885205
11 October 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6835837
10 October 2019
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6832900
20 September 2019
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6816601
8 April 2019
Internal Structural Exam · Drydock Exam · MTSA/ISPS Verification · COI Inspection · Damage Survey · DAPI Audit · Administrative Inspection · In-Service Inspection · Examination of Repairs · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6673371
1 August 2018
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6589278
30 January 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6352042
26 September 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6275609
24 August 2017
DAPI Audit · MTSA Verification · Periodic Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6250175
13 October 2016
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6021686
11 October 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6019882
14 June 2016
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5906853
27 October 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5751897
4 September 2015
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5234666
18 July 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5192158
31 March 2015
Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5093936
3 June 2014
MARPOL Annex I Examination · DAPI Audit · Security Plan Review - VSP · Construction Oversight · MTSA Verification · Initial Certification · MARPOL Annex VI Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4878373
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2021
Resolved
The frame or support of each size III, IV, and V fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck. Both semi-portable extinguishers for the cargo tank area are not secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 24 June 2021
Resolution: Def resolved. Operator now has Semi portable FE affixed to a welded bracket for a more secure arrangement. No further action required at this time.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2019
Resolved
Vessel's anchor cable parted while anchored, lost anchor. Replace anchor and cable prior to departing SENESCO shipyard to the satisfaction of the attending USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 October 2019
Resolved 13 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2019
Resolved
Permanently install ventilation fans in BWTS rooms. A temporary alternate means has been approved and provided ustilizing air compressor and venturi blowers until fans are delievered and installed. Lead time to delivery to vessel is expected 27Aug2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 13 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2019
Resolved
Prove proper operation of interlocks between ventilation fans in the BWTS rooms and the BWTS to prevent operation of the BWTS if the fans are not in operation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 10 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 August 2019
Resolved
Provide updated Certificate of Documenation to reflect new GRT and ITC.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 13 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 August 2019
Resolved
Provide USCG MSC approved Hazardous Location Plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 15 August 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 April 2019
Resolved
Barge broke free of moorings and ran aground on a rock jetty. Conduct drydock and internal inspection of vessel prior to departure and cargo operations.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2019