ENDEAVOUR II is a 2012 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in November 2025, along with 3 deficiencies.
Records from 2016 to 2025. Most recent: inspection, 16 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it2 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
03 air leaks were discovered during working pressure leak test.
- Port Chamber #2 at inflation valve
- Starboard Chamber #3 at inflation valve
- Starboard Chamber #4 approx. 3" below gray rub rail.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2025
Resolved 14 March 2025
Resolution: Verified repair of leaks. All sat. Cleared deficicency.
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
02 air leaks was discovered during working pressure leak test.
Action required: 705 - Other - as specified
Due 14 June 2024
Resolved 3 May 2024
Resolution: Satisfactory working pressure/soap water test.
Inflatable did not have consistent records of tests, visual inspections, training, drills, and tendering operations. O/O indicated company was moving to digital system, HELM. Provide consistent records with new digital system. Rectify deficiency by next Annual Inspection.
Action required: 705 - Other - as specified
Due 25 July 2025
Resolved 14 March 2025
Resolution: Drill record will be maintained on mother ship electronic format (helm).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.