Records from 1995 to 2008. Most recent: inspection, 29 September 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
29 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3334876
12 September 2006
Hull Examination · Ballast Water Examination · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2776217
26 June 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2691999
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539906
7 June 2005
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2382981
12 January 2005
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2294594
24 May 2004
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2077065
26 January 2004
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1993175
15 January 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1749763
12 December 2002
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1717915
9 September 2002
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1674201
11 February 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1485335
21 May 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467292
13 January 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388978
17 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112761
28 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801988
25 February 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386434
22 January 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457525
9 January 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439817
19 December 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380359
26 August 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192555
5 January 1995
Inclining Experiment · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367375
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 3 April 2007
No resolution recorded
Per NVIC 8-91 vessel hydraulic jacking systems must meet the requirementsof 46 CFR 58.30. Provide third party insp. of all system components, to identify systems as fail safe, and any components not rated for maximum system pressure. Repair/replace all identified components . Prior to next annual insp.
Action required: 705 - Other - as specified
Due 3 April 2008 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 February 2002
Resolved
Line and bracket missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2002
Resolution: Replaced same.
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
Engine room hatches not properly marked. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2002
Resolution: Marked same.
Lifesaving
Issued 25 February 1999
Resolved
Demonstrate compliance with the 8th Coast Guard District's Policy "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Documentation
Issued 5 January 1995
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER_x001C_FOR ISSUANCE OF A STABILITY LETTER; PROVIDE ON BOARD.
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Documentation
Issued 5 January 1995
Resolved
PROVIDE APPROVED PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, AND STRUCTURAL ANALYSIS OF ALL LEGS AND TOWER SUPPORTS.
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Documentation
Issued 5 January 1995
Resolved
PROVIDE APPROVED PLANS FOR THE NEWLY INSTALLED PORT CRANE SHOWING UNDER DECK STRENTHENING, ETC.
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Documentation
Issued 5 January 1995
Resolved
PROVIDE ON BOARD AN APPROVED OPERATING MANUAL MEETING 46 CFR 109.121 AND NVIC 8-91.
Condition: Unknown
Due 5 January 1995