MAURY USCG vessel records
← All vessels

IZABELLA M

IZABELLA M is a freight ship. The Coast Guard has recorded 1 inspection in 2023, along with 7 deficiencies — 1 with no resolution recorded —.

Records in 2023. Most recent: inspection, 7 December 2023.

Built
Not recorded
Last inspected
7 December 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 December 2023
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9523500
1172015
Flag
LIBERIA
Maury page id
psix-1172015

Documentation record

Tonnage as PSIX records it79141 - Dead Weight, Ton
28236 - Simplified, Net Ton
39295 - Convention (Subpart B), Gross Ton
35295 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

7 December 2023 PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7832378

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2023 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed excessive leakage of the M/E jacket water cooling from the M/E cylinder #6 cooling jacket liner. 74SOLAS(20) II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2023
Resolution: Received Class Report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 December 2023 No resolution recorded
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed exposed electrical connections on multiple electrical boxes on weather deck. 74SOLAS(20) II-I/40.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 December 2023 Resolved
Fire doors in main verticle zone bulkheads, galley boundary, and stairway enclosures... shall be self closing and be capable of closing with an angle of inclination of up to 3.5 degres opposing closure. PSCO observed "A" class self closing fire door to "B" deck stairway not able to self close. 74SOLAS(09) II-2/9.4.1.1.4.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 December 2023
Resolution: Received Class Report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 December 2023 Resolved
Maintenance of lifesaving shall be carried out in a manner having due regard to ensuring reliability of such appliances. PSCO observed several gallons of fuel in lifeboar engine compartment. Crew removed fuel and replaced fuel hose to engine. 74SOLAS(20) III/20.3.1
Action required: 10 - Deficiency Rectified
Resolved 7 December 2023
Resolution: Crew removed fuel and replaved fuel hose to engine.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 7 December 2023 Resolved
Each abandon ship drill shall include... reporting to stations and preparing for the duties described in the muster list. PSCO observed crew members that did not bring required items during abndon ship drill. Crew repeated drill.
Action required: 10 - Deficiency Rectified
Resolved 7 December 2023
Resolution: Crew repeated drill.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2023 Resolved
Each lifejacket shall be fitted with a whistle firmly secured by a lanyard. PSCO observed 02 lifejackets missing attached whistle in Bosun Store.
Action required: 10 - Deficiency Rectified
Resolved 7 December 2023
Resolution: Crew attached whistles to lifejackets.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 7 December 2023 Resolved
IAW the requirements of paragraph 6.1 of this regulation shall be trained to implement the guidance provided in the manufacturer's operations mannual. PSCO observed unburned material in incinerator.
Action required: 10 - Deficiency Rectified
Resolved 7 December 2023
Resolution: Crew removed un-incinerated material.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.