Records from 2016 to 2026. Most recent: inspection, 10 March 2026.
Inspection history · 13
10 March 2026
Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8323318
25 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8099576
19 March 2024
Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7882261
24 October 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7813609
14 March 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7650922
2 March 2022
COI Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7404333
2 March 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7148717
25 March 2020
Drydock Extension · Annual Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6931318
26 February 2019
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6632469
12 March 2018
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6373171
14 March 2017
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6103961
29 April 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5865578
15 April 2016
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5855131
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2026
Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements...Suitable compression type connection fittings may be accepted.
Fuel hose connection is corroded.
46 cfr 182.720(e)(3)(v)(A)
Action: 16 c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 19 March 2026
Resolution: Picture of new hose received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050. 46 CFR 180.70(b)(1)
Grab line on the ring life buoy is degrading and needs renewal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 10 April 2025
Resolution: Vessel representative purchased a new ring life buoy with a new grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. 46 CFR 185.604 (i)
Retroreflective material on the life buoy does not adequately reflect light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 10 April 2025
Resolution: Vessel representative applied retroreflective tape to the new ring life buoy.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 March 2025
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training, and a general description of the drill scenario and training topics.46 CFR 185.520 (f)
Vessel did not have any man overboard drills documented.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 10 April 2025
Resolution: Vessel representative logged the man overboard drill done during this annual inspection in a new log book.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 March 2025
Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training; and a general description of the drill scenario and training topics. 46 CFR 185.524 (d)
Vessel did not have any fire drills documented.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 10 April 2025
Resolution: Vessel representative conducted a fire drill and logged it into the vessel's new log book.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
ABYC E-9.16.k.10 recommends that batteries have no more than 04 connections to each individual terminal stud. Vessel currently has 05 connections to one of the battery studs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 10 April 2025
Resolution: Vessel redistributed the number of connections to each stud so that neither one has more than 04 connections.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 March 2021
Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:
(1) Three hand red flare distress signals approved in accordance with §160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Replace expired flares to meet required amount.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 24 March 2021
Resolution: Replaced the flares
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 02 life jackets were un-serviceable. Reduced to 10 passengers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 March 2021
Resolution: Replaced the missing life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2021
Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.Battery was expired.
Limited to daytime and clear visibility operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 March 2021
Resolution: replaced the expired battery
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 March 2021
Resolved
A portable hand bilge pump must be:
(1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and
(2) Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Bilge hand pump is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 24 March 2021
Resolution: replaced hand bilge pump
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 March 2021
Resolved
Except as provided in 173.17, no person may use a vessel to which this part applies unless: It has a number issued on a certificate of number by the issuing authority in the State of principal operation; and the number is displayed as described in 173.27.
Vessel's principal operation in in South Carolina as a Commercial Passenger Vessel, but is registered as (Personal Passenger Vessel/Other-State Vessel/Personal Pleasure). Contact SC-DNR to make changes to state registration per regulation and provide documentation to OCMI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2021
Resolved 24 March 2021
Resolution: applied for commercial registration
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 10 March 2021
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Aft part of the vessel has no railings and railing restricting passenger movement past operation station were not installed. Vessel placed two lines in service to correct missing courses.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 March 2021
Resolved 10 March 2021
Resolution: lines put in place
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 March 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 24 March 2021
Resolution: Corrected the bilge pump visual indicator
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 February 2019
Resolved
VHF safety radio is expired and DSC not programmed. Restricted to 1000 feet from shore.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 28 February 2019
Resolution: DSC is extended until next drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2019
Resolved
Fuel filters must be of metal type.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 15 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2019
Resolved
Fuel shut off not present and not labeled.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 6 March 2019
Operations/Management › Vessel Activity › Other
Issued 12 March 2018
Resolved
Make vessel available to test outboard motor.
Due 12 April 2018
Resolved 29 March 2018
Lifesaving › Lifebuoys › Serviceable
Issued 12 March 2018
Resolved
Replace worn life ring.
Due 12 April 2018
Resolved 29 March 2018