MAURY USCG vessel records Sign in
← All vessels

CONDOR BILBAO

CONDOR BILBAO is a 2012 freight ship. The Coast Guard has recorded 9 inspections since 2015, most recently in April 2023, along with 2 deficiencies and 1 operational control.

Records from 2015 to 2023. Most recent: inspection, 18 April 2023.

Built
2012
Last inspected
18 April 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9473250 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1172111
Flag
CYPRUS
—
Maury page id
psix-1172111

Inspections, by type

…with no type recorded4
Years with a record 4 calendar years (2015–2023)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12795 - Convention (Subpart B), Gross Ton
5486 - Convention (Subpart B), Net Ton
17215 - Dead Weight, Metric Ton
6417 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PTS 3 Freight Barge · MISLE 45055 · 15 July 2015 · activity 5197874AMERICAN EAGLE Towing Vessel · MISLE 105484 · 15 July 2015 · activity 5197874

Inspection history · 9

18 April 2023 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7662487
11 April 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6122183
26 March 2017 ISPS II Exam · COE-Offshore · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6109592
21 March 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6109252
3 January 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5789978
17 December 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5782417
16 July 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5186185
15 July 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5197874
14 July 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5185538

Deficiency record · 2

Fire Fighting › Fire Main › Valves
Issued 26 March 2017 Resolved
0725- Fixed Fire Extinguishing Installation- Fixed Fire Extinguishing systems shall be installed having due regard to the fire growth potential of the protected spaces. Valve # 24 in engine room fire main is cracked rendering the valves integrity compromised. Valve #24 serves for deck fire fighting appliances. 16s
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 11 April 2017
Resolution: RECEIVED CLASS REPORT, PART DELIVERY NOTE, AND PHOTOS ATTESTING TO THE REPAIR.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 17 December 2015 Resolved
Main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Natural ventilation into emergency generator room from "A" deck is not capable of being closed. 74 SOLAS Con. Ed. 2009 Ch. II-2/5.2.1.1 Action: 16a
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 December 2015
Resolved 3 January 2016
Resolution: Received class report from LR attesting to the rectification of deficienci. Crew fabricated and installed a proper closing mechanism (vent flap) with screw down dogs that allow the ventilation to emergency generator room to be closed in the event of fire.

Ownership record