← All vessels
AMANDA C
AMANDA C is a 2012 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in July 2026, along with 3 deficiencies and 2 operational controls, 1 with no removal date recorded.
Records from 2016 to 2026. Most recent: inspection, 27 July 2026.
- Built
- 2012
- Last inspected
- 27 July 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9482782
V7SO4
1172361
Flag
MARSHALL ISLANDS
Maury page id
psix-1172361
Inspections, by type
…with no type recorded2
Years with a record
6 calendar years (2016–2026)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it23456 - Convention (Subpart B), Gross Ton
11522 - Convention (Subpart B), Net Ton
43631 - Displacement, Metric Ton
34447 - Dead Weight, Metric Ton
11522 - Convention (Subpart B), Net Ton
43631 - Displacement, Metric Ton
34447 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 14
27 July 2026
PSC B · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8434632
9 March 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8090605
19 December 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8046558
13 December 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8047039
7 December 2018
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6593836
20 November 2018
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6584026
28 September 2018
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6550646
27 September 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6550256
26 September 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6548856
14 May 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6414522
12 May 2018
COE-Administrative · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6412756
29 November 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6314019
16 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6308095
29 November 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6046128
Deficiency record · 3
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 27 July 2026
Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. PSCO observed electrical conduit entering junction box on starboard main deck in the vicinity of the cargo holds wasted, bringing into question the safety of electrical wiring. Provide clarification by the issuing authority prior to loading of dangerous goods.
SOLAS 74 (95 Amend.) II-1/45 705 a/c
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 20 November 2018
Resolved
14104: Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. Vessel is equipped with 2 solenoid valves on the discharge side of Oily Water Separator. 15 ppm alarm is activated, both solenoid valves close. OWS builds internal pressure, shutting the system down, not allowing vessel to process oily bilge water. MARPOL Annex I 14.7 16 a,c
Lifesaving › Inflatable Liferafts › Float Free
Issued 29 November 2017
Resolved
0620-Liferafts. Each liferaft shall be stowed with a float-free arrangement complying with the requirements of the LSA Code. PSCO observed the float-free arrangement was incorrectly configured. SOLAS 74 (2014) III/13.4.2 LSA 4.1.6 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.