MAURY USCG vessel records
← All vessels

C HUNNA

C HUNNA is a 2012 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in April 2026, along with 1 deficiency.

Records from 2016 to 2026. Most recent: inspection, 24 April 2026.

Built
2012
Last inspected
24 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 April 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9476965
1172544
Flag
PANAMA
Maury page id
psix-1172544

Documentation record

Tonnage as PSIX records it33900 - Convention (Subpart B), Gross Ton
20020 - Convention (Subpart B), Net Ton
61683 - Dead Weight, Metric Ton
70847 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

24 April 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8355203
11 December 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6864998
2 December 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6865303
13 November 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6578018
8 September 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5995888

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2018 Resolved
07113 FIRE SAFETY THE ARRANGEMENT OF SEA CONNECTIONS, FIRE PUMPS AND THEIR SOURCES OF POWER SHALL BE AS TO ENSURE THAT: IN CARGO SHIPS, IF A FIRE IN ANY ONE COMPARTMENT COULD PUT ALL THE PUMPS OUT OF ACTION, THERE SHALL BE AN ALTERNATIVE MEANS CONSISTING OF AN EMERGENCY FIRE PUMP COMPLYING WITH THE PROVISIONS OF THE FSS CODE WITH ITS SOURCE OF POWER AND SEA CONNECTION LOCATED OUTSIDE THE SPACE WHERE THE MAIN FIRE PUMPS OF THEIR SOURCES OF POWER ARE LOCATED. PSCO OBSERVED THE EMERGENCY FIRE PUMP WAS NOT OPERATIONAL DUE TO NO SUCTION BEING PROVIDED. SOLAS 74(A) 2004 CONS. II-2/10.2.2.3.1.2 60A
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2018
Resolution: Vessel sent in class survey report and repaired the emergency fire pump. They discovered a defecting ball bearing of the vacuum pump for emergency fire pump was worn out. The defective bearing has been replaced together with oil seal from the ship's spare

Ownership record