Records from 1998 to 2026. Most recent: inspection, 8 July 2026.
Inspection history · 17
8 July 2026
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8434696
24 July 2025
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8191791
9 October 2024
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8015580
1 February 2024
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7857371
12 October 2023
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7806723
4 October 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7563561
3 August 2021
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7275911
18 May 2020
Initial Certification
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6955120
23 July 2013
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4668316
11 June 2011
Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4046378
10 January 2011
Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3924298
29 April 2010
Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3727033
27 May 2008
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3219310
14 April 2008
Uninspected Other
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3185189
19 May 1999
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 429584
7 May 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 416436
30 April 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 415420
08 - Alarms › N/A - No Subsystem › General alarm
Issued 24 July 2025
Resolved
Each towing vessel must be fitted with a general alarm that is activated at each operating station and can notify persons onboard in the event of an emergency, is capable of notifying persons in any accommodation, work space, and the engine room, has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station” and A public-address (PA) system or other means of alerting all persons on the towing vessel may be used in lieu of the general alarm in paragraph (b) of this section if the system meets the requirements of paragraphs (b)(2) and (3) of this section. Vessel did not have a general alarm meeting paragraphs 2 and 3.
46CFR143.235
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 July 2026
Resolution: General alarm installed meeting the requirements of 46CFR.143.235
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 July 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels.
46CFR143.203
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 July 2026
Resolution: High bilge alarm installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2025
Resolved
Lifejackets must have the following attachments and fittings: Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Lifejackets did not have the correct lights attached.
46CFR141.340
Action required: 10 - Deficiency Rectified
Resolved 29 July 2025
Resolution: O/O purchased approved lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2025
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Vessel only had 1 lifebuoy with a floating water life.
46CFR141.360
Action required: 10 - Deficiency Rectified
Resolved 29 July 2025
Resolution: O/O purchased floating electric water light.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 July 2025
Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures. Vessels H&S plan did not meet the requirements in 46CFR150.505-515.
46CFR140.500
Action required: 10 - Deficiency Rectified
Resolved 29 July 2025
Resolution: O/O updated H&S Plan
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Flange was discovered exposed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 November 2024
Resolved 9 October 2024
Resolution: Lagging replaced on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2022
Resolved
Life jackets must have the following attachments and fittings: (1) Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket. (2) Each life jacket must have a whistle firmly secured by a cord to the life jacket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2022
Resolved
If a towing vessel carries only one lifebuoy, the lifebuoy must be fitted with a floating electric water light approved under approval series 161.010 or 160.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. Floating water light was found extinguished, replace battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 October 2022
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Add instructions to fuel shut offs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 October 2022
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Replace worn lagging, and add additional lagging on turbo chargers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Properly mount electrical outlet in galley space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2022
Resolved
Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Properly splice connections in the engine room in the vicinity of main engines, and generator.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2022
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Replace wing nut on battery outboard of generator.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 October 2022
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Repair dog on aft deck cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 4 October 2022
Resolved
The cognizant OCMI may require review of a vessel's watertight and weather tight integrity. This review may be performed by an individual who meets the requirements of § 144.140. Repair crack on STBD bulkhead, and hole from prior shore tie connection location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 7 November 2022
Resolution: Received photo verification.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 14 April 2008
Resolved
Provide fire detection system that complies with 27.203 currently does not have circuit fault dectector
Action required: 705 - Other - as specified
Resolved 6 November 2013
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 April 2008
Resolved
Provide fuel shutoffs operable from a safe place outside engine room. 46 CFR 27.207
Action required: 705 - Other - as specified
Resolved 23 July 2013
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 14 April 2008
Resolved
Provide fixed fire fighting in accordance with 26 CFR 27.303 or approved B V semiporable fire-extinguishing system.
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 27 May 2008
Resolution: Owner/Operator has purchased an approved B-V semi portable fire-extinguishing system.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 14 April 2008
Resolved
Repair fixed fire pump. 46 CFR 27.301
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 27 May 2008
Resolution: Owner has installed new fire pump.
Fire Fighting › Fire Hoses › Condition
Issued 14 April 2008
Resolved
Repair fire hose holder to allow hose to be deployed without interference 46 CFR 27.301
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 27 May 2008
Resolution: New pipe joint added to fire station to facilitate hose deployment.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 April 2008
Resolved
Provide mounting brackets for B 1 fire extinguishers on Main Deck and wheelhouse. 46 CFR 25.30-20
Action required: 705 - Other - as specified
Resolved 23 July 2013