← All vessels
TTM HARVEST
TTM HARVEST is a freight ship. The Coast Guard has recorded 5 inspections since 2012, most recently in August 2025, along with 6 deficiencies.
Records from 2012 to 2025. Most recent: inspection, 13 August 2025.
- Built
- Not recorded
- Last inspected
- 13 August 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9514028 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FKJ
1173245
Flag
PANAMA
—
Maury page id
psix-1173245
Inspections, by type
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it31540 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
13 August 2025
PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8203726
23 March 2024
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7883813
14 April 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7668897
4 April 2023
PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7662533
11 May 2012
PII Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4307858
Deficiency record · 6
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 August 2025
Resolved
The company and the ship shall comply with the requirements of the international safety management code. The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations. PSCO observed the use of an open flame to test flame detector above oil purifier. Upon request to see safety management system procedures for testing flame detectors, no procedures could be produced.
74 SOLAS (20) IX/3.1
ISM code Part A 10.1
50AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2024
Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended. It was report that the number 6 and 2 high pressure fuel pumps failed on the main engine.
SOLAS 74 (Amended) II-1/26 60 ac
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 April 2023
Resolved
07105 - Fire Doors - Fire doors in stairway closures shall be self-closing. "A" deck fire did not self closed.
74 SOLAS 2020 II-2/9.4.1.1.5.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 April 2023
Resolved
Cabin doors in "B" class divisions shall be of self-closing type. Hold back hooks are not permitted. PSCO observed hold back hooks in ships office, a "B" class division.
74 SOLAS 2020 II-2/9.4.1.2.2
Operations/Management › Drills/Instruction › Fire
Issued 11 May 2012
Resolved
Drills shall be conducted IAW SOLAS regulation 19 of Ch III. Vessel crew did not display required proficiency to meet requirement of regulation. Crew began to pre-stage equipment prior to commencing drills. Drill was immediately changed from fire drill to abandon ship drill. Crew was unfamiliar with equipment and fire fighting procedures. Crew failed two consecutive drills.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 11 May 2012
Resolved
The function of the fixed fire detection shall be periodically tested in which the detector is designed to respond. Vessel does not have proper fire alarm testing equipment on board.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.