Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 28
19 May 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8375259
17 April 2025
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8109634
7 March 2025
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8091733
14 May 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7912784
31 May 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7701521
22 December 2022
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7612044
3 August 2022
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7524592
26 October 2021
Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7340531
11 June 2021
Examination of Repairs · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7193851
9 March 2021
Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7152562
22 December 2020
Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7117703
30 October 2020
Plan Review "T" Boat
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7088334
23 October 2020
Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7084263
28 July 2020
Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7018905
5 May 2020
COI Inspection · Deficiency Check · DAPI Audit · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6949652
16 December 2019
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6879474
17 July 2019
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6798154
28 June 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6717780
9 October 2018
Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6557250
28 June 2018
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6482553
15 June 2018
Deficiency Check · Examination of Repairs · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6438148
18 April 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6393844
14 March 2018
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6371602
9 June 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6176440
20 February 2017
Plan Review "T" Boat · Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6277412
5 December 2016
Plan Review "T" Boat
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6052725
19 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5986258
29 February 2016
Hull Examination · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5823687
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
The materials and construction of flexible hose must meet the requirements of § 182.720(e) of this part.
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600)and must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose and end fittings must comply with SAE J-1475 (incorporated by reference; see 46 CFR 175.600).
Replace fuel oil suply and return lines at the tank with hoses that meet the requirements in 46 CFR 182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 30 June 2024
Resolution: Lines replaced with hoses meeting J-1942
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 August 2022
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted in a conspicuous place on the vessel where observation by passengers is likely. Post COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2022
Resolution: COI posted
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2022
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Replace water light battery. Restricted to daytime operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2022
Resolution: New battery provided for waterlight
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 August 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2022
Resolution: valves properly marked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Remove or properly wire dead end wiring in the water tank room and the space aft of the tank room and in all other spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2022
Resolution: dead end wires placed inside electrical boxes
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 February 2022
Resolved
The scope of an internal structural exam shall include a complete examination of the vessels main strength members, including major internal framing. Existing framing in way of port side shell & chine in Void #2 & #3 (fuel tank space) requires replacement due to rot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 3 August 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 October 2021
Resolved
The scope of an internal structural exam shall include a complete examination of the vessels main strength members, including major internal framing. Existing main deck longitudinal deck beams IWO Voids #2, #3 & #5 require repairs due to water damage (rot).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2022
Resolved 3 August 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 October 2021
Resolved
The scope of an internal structural examination includes the examination of hull plating, voids and main strength members. Damage noted IWO starboard quarter (external) IWO rubrail that is suspected of causing water ingress into the vessels hull IWO void #5 (machinery space).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2021
Resolved 3 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2021
Resolved
Vessels ring life buoys are required to be fitted with rescue line. Existing rescue line was found UV deteriorated & required replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 14 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2021
Resolved
Vessels ring life buoy floating waterlight is required to be attached via lanyard of at least 3' & not more than 6' in length. Existing lanyard was UV deteriorated requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 14 September 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Rot noted IWO main deck longitudinal deck beams (tank room).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
Resolution: Repairs completed, reference activity #7152562.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Rot noted IWO port quarter ceiling/overhead in machinery space/engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 19 January 2021
Resolution: Attending Inspector verified final repairs made IWO port quarter gunwale/machinery space overhead.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Open communication noted IWO longitudinal deck beams and watertight bulkheads (requires re-sealing).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 15 May 2020
Resolution: Attending Inspector verified the (re) sealing of main deck longtudinal deck beams @ watertight bulkheads.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service. Lighting fixtues IWO engine room/machinery space were extinguished at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 15 May 2020
Resolution: Attending Inspector verified installation of lighting fixture IWO engine room.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Water intrusion noted IWO main deck vertical supports for main deck in machinery space/engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2019
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld]/Operator intends to repair/modify bench seating IWO bow (port/starboard sides) due to water intrusion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2020
Resolved 6 May 2020
Resolution: O/O elected to remove existing bench seating IWO port & starboard main deck @ bow.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2019
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] noted IWO main deck around fore/aft mast assemblies/seating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2020
Resolved 22 March 2021
Resolution: Repairs completed, reference activity #7152562.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 June 2019
Resolved
Vessels navigational publications for areas transited were outdated/expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2019
Resolved 31 July 2019
Resolution: Verified carriage of current/up to date navigational publications.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2019
Resolved
Remote emergency fuel shut-off valve(s) were not properly marked/identified.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2019
Resolved 31 July 2019
Resolution: Verified markings for emergency fuel shut-off valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2019
Resolved
One adult Type I PFD was found torn/holed, required replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2019
Resolved 31 July 2019
Resolution: Verified renewal of Type I PFD (adult).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2019
Resolved
Troubleshoot/repair fixed bilge suction IWO void #4. *System was unable to draw suction from space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2019
Resolved 31 July 2019
Resolution: Performed operational test of fixed bilge system IWO void #4.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 June 2018
Resolved
Fire extinguishers did not have current annual servicing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified servicing of portable fire extinguishers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 June 2018
Resolved
FCC Safety Radiotelephony Certificate was expired
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified reneweal of FCC Safety Radio-telephony Certificate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2018
Resolved
Vessel owner/operator was unable to provide current proof of enrollment in a Maritime Consortium for chemical testing
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified current/up to date proof of enrollment letter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2018
Resolved
PFD stowage markings were worn/illegible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified PFD stowage markings (type/qty).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2018
Resolved
Vessel did not have spanner wrench at main deck fire station
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified carriage of spanner wrench IWO main deck fire station.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 15 June 2018
Resolved
Vessel had expired items in the first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified renewal of expired items IWO first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 June 2018
Resolved
Fixed bilge system did not work as designed
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified repairs made IWO fixed bilge piping system @ manifold. Performed operational test of forepeak & machinery space voids. Test sat.
Navigation › Piloting/Steering › Marine Charts
Issued 9 June 2017
Resolved
Vessel did not carry current/up to date navigational publications (Marine Charts, Tidal Current Tables, USCG Light List & Coast Pilot)
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 11 July 2017
Resolution: Attending Inspector verified carriage of navigational publications for vessels area of operation.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 June 2017
Resolved
Vessel did not have their EAP (program) posted on board.
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 3 August 2017
Resolution: Attending Inspector(s) verified carriage/posting of EAP (policy).
Communications › Radio Communications › VHF Radiotelephone
Issued 9 June 2017
Resolved
Vessels VHF-FM radio was not programmed with MMSI number (DSC equipped)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 11 July 2017
Resolution: Vessels primary VHF-FM marine radio was programmed with MMSI number (DSC equipped).
Engineering › Bilge Water Management System › Pump
Issued 9 June 2017
Resolved
Vessels elecrical submersible bilge pumps were not equipped with external float switch for automatic operation in way of machinery space.
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 11 July 2017
Resolution: Attending Inspector verified installation of external float switches for electric submersible bilge pumps in way of machinery space. Performed satisfactory operational test of both pumps.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 June 2017
Resolved
Vessels thru-hull fittings were not IAW 46 CFR 182.720 (non-metallic thru-hull fittings installed throughout)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 3 August 2017
Resolution: Attending Inspector(s) verified installation of thru-hull fittings and stop valves (all compartments). Performed successful operational test of each stop valve.
Documentation › Markings/Placards › Warning Signs
Issued 9 June 2017
Resolved
Vessel not equipped with proper emergency escape markings for main deck.
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 11 July 2017
Resolution: Attending Inspector verified installation/posting of emergency exit signage.