← All vessels
TREASURE HUNTER
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Southeast District (CGD-SE) · Other hulls named TREASURE HUNTER
TREASURE HUNTER is a 2012 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in May 2026, along with 34 deficiencies and 2 casualty investigations between 2018 and 2019.
Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
- Built
- 2012
- Last inspected
- 19 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 34 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2018–2019
Identity
1239409
1173339
Flag
UNITED STATES
367568080
Maury page id
psix-1173339
Inspections, by type
…with no type recorded2
Years with a record
11 calendar years (2016–2026)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)54.0 ft × 19.0 ft × 4.0 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS INC · CRISFIELD, MD, UNITED STATES · built 2012
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portNORTH MYRTLE BEACH, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
21 - Simplified, Net Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDG7515MMSI 367568080 · active · compulsorily equipped · granted 30 March 2023, expires 29 March 2033 · licensed under a name not among this hull’s recorded names (not shown)
WDG3517MMSI 367526860 · expired · compulsorily equipped · granted 24 April 2012, cancelled 25 June 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
19 May 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8375259
17 April 2025
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8109634
7 March 2025
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8091733
14 May 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7912784
31 May 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7701521
22 December 2022
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7612044
3 August 2022
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7524592
26 October 2021
Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7340531
11 June 2021
Examination of Repairs · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7193851
9 March 2021
Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7152562
22 December 2020
Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7117703
30 October 2020
Plan Review "T" Boat
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7088334
23 October 2020
Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7084263
28 July 2020
Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7018905
5 May 2020
COI Inspection · Deficiency Check · DAPI Audit · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6949652
16 December 2019
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6879474
17 July 2019
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6798154
28 June 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6717780
9 October 2018
Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6557250
28 June 2018
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6482553
15 June 2018
Deficiency Check · Examination of Repairs · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6438148
18 April 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6393844
14 March 2018
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6371602
9 June 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6176440
20 February 2017
Plan Review "T" Boat · Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6277412
5 December 2016
Plan Review "T" Boat
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6052725
19 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5986258
29 February 2016
Hull Examination · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5823687
Deficiency record · 34
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
The materials and construction of flexible hose must meet the requirements of § 182.720(e) of this part.
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600)and must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose and end fittings must comply with SAE J-1475 (incorporated by reference; see 46 CFR 175.600).
Replace fuel oil suply and return lines at the tank with hoses that meet the requirements in 46 CFR 182.720(e)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 August 2022
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted in a conspicuous place on the vessel where observation by passengers is likely. Post COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2022
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Replace water light battery. Restricted to daytime operations.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 August 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Remove or properly wire dead end wiring in the water tank room and the space aft of the tank room and in all other spaces.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 February 2022
Resolved
The scope of an internal structural exam shall include a complete examination of the vessels main strength members, including major internal framing. Existing framing in way of port side shell & chine in Void #2 & #3 (fuel tank space) requires replacement due to rot.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 October 2021
Resolved
The scope of an internal structural exam shall include a complete examination of the vessels main strength members, including major internal framing. Existing main deck longitudinal deck beams IWO Voids #2, #3 & #5 require repairs due to water damage (rot).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 October 2021
Resolved
The scope of an internal structural examination includes the examination of hull plating, voids and main strength members. Damage noted IWO starboard quarter (external) IWO rubrail that is suspected of causing water ingress into the vessels hull IWO void #5 (machinery space).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2021
Resolved
Vessels ring life buoys are required to be fitted with rescue line. Existing rescue line was found UV deteriorated & required replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2021
Resolved
Vessels ring life buoy floating waterlight is required to be attached via lanyard of at least 3' & not more than 6' in length. Existing lanyard was UV deteriorated requiring replacement.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Rot noted IWO main deck longitudinal deck beams (tank room).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Rot noted IWO port quarter ceiling/overhead in machinery space/engine room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Open communication noted IWO longitudinal deck beams and watertight bulkheads (requires re-sealing).
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service. Lighting fixtues IWO engine room/machinery space were extinguished at time of inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 May 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended and complies with all applicable regulations. Water intrusion noted IWO main deck vertical supports for main deck in machinery space/engine room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2019
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld]/Operator intends to repair/modify bench seating IWO bow (port/starboard sides) due to water intrusion.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2019
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] noted IWO main deck around fore/aft mast assemblies/seating.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 June 2019
Resolved
Vessels navigational publications for areas transited were outdated/expired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2019
Resolved
Remote emergency fuel shut-off valve(s) were not properly marked/identified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2019
Resolved
One adult Type I PFD was found torn/holed, required replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2019
Resolved
Troubleshoot/repair fixed bilge suction IWO void #4. *System was unable to draw suction from space.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 June 2018
Resolved
Fire extinguishers did not have current annual servicing
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 June 2018
Resolved
FCC Safety Radiotelephony Certificate was expired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2018
Resolved
Vessel owner/operator was unable to provide current proof of enrollment in a Maritime Consortium for chemical testing
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2018
Resolved
PFD stowage markings were worn/illegible.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2018
Resolved
Vessel did not have spanner wrench at main deck fire station
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 15 June 2018
Resolved
Vessel had expired items in the first aid kit
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 June 2018
Resolved
Fixed bilge system did not work as designed
Navigation › Piloting/Steering › Marine Charts
Issued 9 June 2017
Resolved
Vessel did not carry current/up to date navigational publications (Marine Charts, Tidal Current Tables, USCG Light List & Coast Pilot)
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 June 2017
Resolved
Vessel did not have their EAP (program) posted on board.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 June 2017
Resolved
Vessels VHF-FM radio was not programmed with MMSI number (DSC equipped)
Engineering › Bilge Water Management System › Pump
Issued 9 June 2017
Resolved
Vessels elecrical submersible bilge pumps were not equipped with external float switch for automatic operation in way of machinery space.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 June 2017
Resolved
Vessels thru-hull fittings were not IAW 46 CFR 182.720 (non-metallic thru-hull fittings installed throughout)
Documentation › Markings/Placards › Warning Signs
Issued 9 June 2017
Resolved
Vessel not equipped with proper emergency escape markings for main deck.
Casualty record · 2
28 June 2018Routine · role: Involved in a Marine Casualty · 1 injured · activity 6482553
17 July 2019Routine · role: Involved in a Marine Investigation (non-casualty) · 1 dead · activity 6798154
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.