← All vessels
CORNELIA M
CORNELIA M is a 2012 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in June 2026, along with 6 deficiencies and 3 operational controls.
Records from 2016 to 2026. Most recent: inspection, 24 June 2026.
- Built
- 2012
- Last inspected
- 24 June 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded4
Years with a record
7 calendar years (2016–2026)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it78400 - Dead Weight, Metric Ton
90625 - Displacement, Metric Ton
25953 - Convention (Subpart B), Net Ton
41799 - Convention (Subpart B), Gross Ton
90625 - Displacement, Metric Ton
25953 - Convention (Subpart B), Net Ton
41799 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 11
24 June 2026
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8405316
7 September 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7998274
7 September 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8001314
17 July 2024
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7942455
23 December 2021
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7361899
23 December 2021
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7372055
29 April 2020
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6941387
19 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6866157
25 August 2018
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6522270
7 May 2018
ISPS II Exam · PII Safety Exam · Deficiency Check · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6404250
6 December 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6049082
Deficiency record · 6
Lifesaving › Hand Flares › Expired
Issued 7 May 2018
Resolved
0600-Life saving appliances- Lifesaving appliances shall be in working order ready for immediate use. The onboard line throwing appliances and pyro are expired.74SOLAS (14) III/20.2
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 May 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 May 2018
Resolved
1740-oil discharge monitor/control system-THE SHIP MUST BE FITTED WITH AN ELECTRONIC DEVICE WHICH SHOULD BE PRESET BY THE MANUFACTURER TO ACTIVATE WHEN THE EFFLUENT EXCEEDS 15PPM OR AT ANY TIME THE 15PPM BILGE ALARM SHOULD FAIL TO FUNCTION. IN ADDITION THE ARRANGEMENT FOR THE EXTRACTION OF SAMPLES FROM THE 15PPM BILGE SEPARATOR DISCHARGE LINE TO THE 15PPM BILGE ALARM SHOULD GIVE A TRULY REPRESENTATIVE SAMPLE OF THE EFFLUENT WITH AN ADEQUATE PRESSURE AND FLOW. THE OILY WATER SEPARATOR CONTINUES TO OPERATE WITHOUT ALARM WHEN THE SAMPLING VALVE TO THE 15PPM BILGE ALARM IS CLOSED AND NO EFFLUENT IS FLOWING TO THE 15PPM BILGE ALARM. MARPOL I/14.7 and MEPC 107.49/4.2.7 % 6.2.2
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 6 December 2016
Resolved
1399-Other, (Mooring Arrangements)-THe condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the port side anchor chain separator was damaged and removed. 74SOLAS(09)I/11a 40ac
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 6 December 2016
Resolved
2555-Documentation-The company should ensure that obsolete documents are promptly removed. Vessels ISM-DOC reflects the obsolete company name and has not been updated since the change, 01OCT16. Company IMO number has not changed, and remains correct. ISM Code 11.2.3 40ac
Lifesaving › Inflatable Liferafts › Float Free
Issued 6 December 2016
Resolved
0628-Stowage of Liferafts-Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the port side liferaft tied with rope to the cradle. Ships crew promptly removed. 74SOLAS(09) III/20.2 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.