MAURY USCG vessel records
← All vessels

GOOD TIMES

GOOD TIMES is a 2012 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2017, most recently in November 2025, along with 38 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 24 November 2025.

Built
2012
Last inspected
24 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 November 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG4576
1174310
Flag
UNITED STATES
Maury page id
psix-1174310

Documentation record

Registered dimensions (L × B × D)47.0 ft × 15.8 ft × 4.5 ft
Registered tonnagegross 14 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOOPER MARINE INC · ST PETERSBURG, FL, UNITED STATES · built 2012
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 14 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

24 November 2025 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8268426
23 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8239783
25 February 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8093433
14 February 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7862302
26 September 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7796471
22 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7639717
18 January 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7375537
14 September 2021 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7257819
8 July 2021 DAPI Audit · In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7249178
9 December 2020 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7088497
12 March 2020 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6908558
17 September 2019 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6802772
11 February 2019 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6618477
1 March 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6401268
16 October 2017 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6323326
1 February 2017 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6080781

Deficiency record · 38

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2025 Resolved
Replace the fuel hose section between the fuel filter and primer bulb for both the port and starboard engines with approved USCG Type A1, A2, B1, or B2 flexible fuel hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2025
Resolved 4 December 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 November 2025 Resolved
Create drill entry logs for all abandon ship, man overboard, and fire fighting drills conducted. Entry logs must include the date of the drill, the crewmembers involved in the drill, and a general description of the drill.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2025
Resolved 4 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 February 2023 Resolved
The pin on a 40-B:C portable fire extinguisher was corroded and preventing removal and handle depression. Vessel rep replaced with new 40-B:C portable fire extinguisher.
Action required: 10 - Deficiency Rectified
Resolved 22 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 February 2023 Resolved
Properly label the life jacket stowage bins with the size (adult or child) and number of life jackets stowed inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 January 2022 Resolved
Vessel's EPIRB battery was expired. Vessel rep purchased, registered and installed a new Category 1, 406 MHz EPIRB. Deficiency rectified on the spot.
Action required: 10 - Deficiency Rectified
Resolved 18 January 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 January 2022 Resolved
Vessel's nautical publications were not up-to-date. Vessel rep purchased an adequate and up-to-date U.S. Coast Pilot [name withheld] List and Tide Tables. Deficiency rectified on the spot.
Action required: 10 - Deficiency Rectified
Resolved 18 January 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 January 2022 Resolved
Vessel has a LED flood light with a 180 degree arc as its masthead light. Install a masthead light in accordance with the International and Inland Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 February 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 September 2021 Resolved
Identified a 12" x 4" section of wasted wood in the deck beam immediately forward of the head (port side). Provide a repair proposal to crop and renew section of deck beam spanning the length of the port hull and complete the work prior to receiving credit drydock.
Action required: 705 - Other - as specified
Resolved 29 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 July 2021 Resolved
Implement a chemical testing program to implement the company's written drug and alcohol testing policy.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 July 2021 Resolved
Provide pre-employment testing documentation for each crewmember in a safety sensitive position.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 July 2021 Resolved
The company does not have the required Employee Assistance Program information and training available to all crewmember's in a safety sensitive position. Provide a Designated Employee Representative, one hour training for personnel in a supervisory position, and a substance abuse professional point of contact.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 July 2021 Resolved
Vessel does not have all crewmembers enrolled in a drug and alcohol testing program. Provide a Captain and a Deckhand that are in full compliance with pre-employment and random drug and alcohol testing requirements prior to carrying passengers. 46 CFR 16.210/16.230
Action required: 705 - Other - as specified
Resolved 13 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2020 Resolved
Vessel's ring life buoy was cracking on the outer shell and unserviceable. Replace with a 24" ring life buoy with lifeline. 46 CFR 180.70(a)
Action required: 10 - Deficiency Rectified
Resolved 9 December 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 December 2020 Resolved
Provide updated Coast Pilot. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 January 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 September 2019 Resolved
Repair/replace FRP tabbing on STBD aft deck beams on outboard hull identified by USCG Marine Inspector. Tabbing has separated from wood deck beams.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 October 2019
Resolution: Tabbing repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2019 Resolved
Ensure all electrical appliances have over-current protection. Over-current protection could not be located on wire coming off bus bar under console.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2019 Resolved
Permanent type connectors must be used on battery terminals. Wing nuts found on battery terminal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2019 Resolved
Breaker panel cover must be properly installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 February 2019 Resolved
All publications must be up-to-date. Light list is not current.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 February 2019 Resolved
State registration must be for commercial use. Current registration is for pleasure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 February 2019 Resolved
All pages of COI must be posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 February 2019 Resolved
All pages of the stability letter must be posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 February 2019 Resolved
Vessel name on ring buoy coming off. Rewrite vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 March 2018 Resolved
Provide documentation proving all crew members are enrolled in company's chemical testing program.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 8 March 2018
Resolution: Provided document of all crew members enrolled in consortium.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2018 Resolved
Renew expired battery in life ring water light.
Action required: 10 - Deficiency Rectified
Resolved 1 March 2018
Resolution: Installed new battery in water light.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 March 2018 Resolved
Prove proper operation of visual indicator for starboard high level alarm.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 8 March 2018
Resolution: Replaced visual indicator and demostrated proper operation.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 1 March 2018 Resolved
Provide B-II extinguisher.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 8 March 2018
Resolution: Vessel purchased/installed new B-II portable fire extinguisher.
Engineering › Fuel Oil Service System › Valve
Issued 1 March 2018 Resolved
Properly label fuel shut off valves.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 8 March 2018
Resolution: Labeled fuel shut off valves.
Construction/Loadline › Hull › Hull Plating
Issued 16 October 2017 Resolved
Make repairs to identified areas on hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2017
Resolved 20 October 2017
Resolution: Made repairs.
Construction/Loadline › Hull › Hull Plating
Issued 16 October 2017 Resolved
Grind out unauthorized repairs to hull and make available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2017
Resolution: Areas were ground out and properly repaired.
Fire Fighting › Fire Bucket › Quantity
Issued 1 February 2017 Resolved
Provide 03 fire buckets with proper markings and lanyards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: Purchased new fire buckets with lanyards
Fire Fighting › Fire Bucket › Stenciling
Issued 1 February 2017 Resolved
Properly mark all fire buckets
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 10 March 2017
Resolution: All fire buckets were properly labeled.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 February 2017 Resolved
Prove proper operation of port high level alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: Installed new audible/visual alarm
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 1 February 2017 Resolved
Bond both fuel tanks to a common ground
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 10 March 2017
Resolution: Bonded both fuel tanks to common ground
Communications › Radio Communications › VHF Radiotelephone
Issued 1 February 2017 Resolved
Connect VHF to GPS input
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 10 March 2017
Resolution: Installed new VHF radio with integrated GPS
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 February 2017 Resolved
Renew 01 child size PFD.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 February 2017
Resolution: Renewed damaged PFD
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 February 2017 Resolved
Remove latches from PFD storage boxes.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 10 March 2017
Resolution: Removed latches
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 February 2017 Resolved
Drills and EPIRB test not logged.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.