MAURY USCG vessel records Sign in
← All vessels

UHL PARTNER

UHL PARTNER is a 2010 public freight. The Coast Guard has recorded 12 inspections since 2012, most recently in May 2020, along with 7 deficiencies and 1 operational control.

Records from 2012 to 2020. Most recent: inspection, 13 May 2020.

Built
2010
Last inspected
13 May 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9418999 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1174932
Flag
PORTUGAL
—
Maury page id
psix-1174932

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2012–2020)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it15549 - Convention (Subpart B), Gross Ton
5722 - Convention (Subpart B), Net Ton
27291 - Displacement, Metric Ton
18389 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

13 May 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6952779
13 May 2020 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6952827
10 May 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6951061
23 November 2019 ISPS II Exam · Administrative Inspection · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6856733
25 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6781101
14 July 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6478590
27 November 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6311595
26 November 2017 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6312782
8 September 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5988703
27 October 2014 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5012871
25 March 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4820586
25 May 2012 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4316552

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 November 2019 Resolved
07114-Remote Means of control(opening,pumps,ventilation,etc.) Machinery spaces-Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed DO storage tank quick acting closing valve was blocked. Proper operation of the valve shall be tested. 74 SOLAS (a) 2014 Cons. II-2/4.2.2.3.4 60 A/C
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 November 2019
Resolved 25 November 2019
Resolution: Received, reviewed and accepted class report from DNVGL stating the deficiency was rectified. Surveyor found that the valve would not stay open due to missing lock set screws for the valve stem limiter spacer. Valve was repaired and tested satisfactorily.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 November 2019 Resolved
05111-Satellite EPIRB 406MHz/1.6GHz-Subject to the provisions of regulation 8..3 a satellite emergency position-indicating radio beacon (EPIRB) which shall be capable of floating free is the ship sinks and of being automatically activated when afloat. PSCO observed a life raft hydrostatic release attached to the EPIRB which stated, “Hydrostatic release unit for life rafts of all capacities”. Crew could not find any documentation for the HRU verifying it could be used on an EPIRB. 74SOLAS (a) 2014 Cons. IV/7.6.6.4 17 C
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2019
Resolved 25 November 2019
Resolution: Received, reviewed and accepted class report from DNVGL stating the deficiency was rectified. Crew obtained and installed a proper EPIRB HRU. Class surveyor attested to proper installation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 23 November 2019 Resolved
15105-Resources and Personnel-The company should ensure that all personnel involved in the company safety management system have adequate understanding of the relevant rules, regulations, codes and guidelines. The Chief Engineer provided maintenance records indicating that all quick-closing valves were tested on 18NOV2019, however upon further questioning stated that the valve referenced in Deficiency #1 had not been tested since he joined the vessel in August. An internal SMS audit is required to be completed within 03 months. 74 SOLAS (a) 2014 Cons IX/3.1, ISM Code 6.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2020
Resolved 13 May 2020
Resolution: Sector New Orleans received documentation showing that the vessel's Flag, owner, and operator have changed since deficiency issued and vessel underwent external ISM audit 20Feb2020.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 23 November 2019 Resolved
15110-ISM Documentation-The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO observed a quick closing valve blocked and after requesting procedures for checking quick closing valves the Chief Engineer and Captain stated that the company had no written procedures for monthly checking of quick closing valves. An internal SMS audit is required to be completed within 03 months. 74 SOLAS (a) 2014 Cons IX/3.1, ISM Code 11
Action required: 705 - Other - as specified
Due 23 February 2020
Resolved 13 May 2020
Resolution: Sector New Orleans received documentation showing that the vessel's Flag, owner, and operator have changed since deficiency issued and vessel underwent external ISM audit 20Feb2020.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 25 March 2014 Resolved
0660 - LIFE JACKETS - Before approval testing of lights must comply with requirements of the code. If light is a flashing light it must flash between 50 and 70 flashes/min. 05 lights were inoperable. Crew replaced lights. SIKAS 74 (a) CH III/4, LSA CODE CH II / 2.2.3.2.2.
Due 25 March 2014
Resolved 25 March 2014
Resolution: Crew replaced lights with spares.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 25 March 2014 Resolved
1730 - OWS - PSCO believes that responsible persons are not familiar with essential shipboard procedures. C/E was not familiar with recalling history in the 15ppm bilge monitor. Provide corrective action plan from company. MARPOL 73/78 ANNX I/11, MEPC 107(49)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 March 2014
Resolution: Received report from company detailing corrective action plan with approval from flag state as well.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 25 March 2014 Resolved
2099 - OTHER - No person may cause a vessel to get underway unless no more than 12 hrs. before entering the steering gear from alternative power supply is tested. Vessel was unaware of this specific test. Provide corrective action plan from company with concurrence from flag. SOLAS 74(a) V/26 , 33 CFR 164.25
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 March 2014
Resolution: Received report from vessel''s flag state that familiarity training was conducted to their satisfaction.

Ownership record