MAURY USCG vessel records
← All vessels

MISS GULFPORT

MISS GULFPORT is a 1972 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in February 2026, along with 75 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 26 February 2026.

Built
1972
Last inspected
26 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH2091
1175014
Flag
UNITED STATES
Maury page id
psix-1175014

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 13.5 ft × 6.3 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM, WA, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portST PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 13 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 18

26 February 2026 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8307914
4 December 2025 Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8267917
3 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8074035
16 February 2024 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7859331
22 January 2024 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7839197
27 February 2023 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7627372
15 January 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7368372
15 November 2021 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7353396
13 April 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7171890
22 February 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7123124
13 May 2020 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6946985
13 February 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6896862
14 May 2019 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6676217
23 April 2018 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6381337
8 August 2017 Administrative Inspection · Drydock Exam · Damage Survey · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6236020
27 February 2017 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6102158
12 January 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6065325
24 February 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5821135

Deficiency record · 75

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026 Resolved
The requirements for machinery ... are contained in applicable regulations in subchapter F (Marine Engineering). MI observed unapproved modifications to Detroit Diesel 871 air box. Repair to satisfaction of MI. 46 CFR 182.220 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2026
Resolution: Repairs have been completed to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 February 2026 Resolved
The requirements for machinery ... are contained in applicable regulations in subchapter F (Marine Engineering). MI observed 03 containers filled with oil in the engine room. Remove oil from containers and provide evidence to the satisfaction of the MI. 46 CFR 182.220 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2026
Resolution: Oil has been removed to the satisfaction of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 February 2026 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI observed 01 missing portable light. Replace to the satisfaction of the attending MI. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2026
Resolved 3 March 2026
Resolution: Portable lights have been replaced to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 February 2026 Resolved
The EPIRB test shall be logged or otherwise documented, as applicable. MI observed missing EPRIB entry logs. Provide evidence on documentation to satisfaction of MI. 46 CFR 185.728 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2026
Resolved 3 March 2026
Resolution: Documentation has been provided to the satisfaction of the attending MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 26 February 2026 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. MI observed missing drill logs. Show proof of required drills to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2026
Resolved 3 March 2026
Resolution: Documentation has been provided to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 February 2026 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. MI observed original COI not on board. Replace to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2026
Resolved 3 March 2026
Resolution: Documentation has been replaced to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 February 2026 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. MI observed missing COD. Replace to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2026
Resolution: Documentation has been replaced to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 December 2025 Resolved
Coast Guard Marine Inspector observed 3 areas of fiberglass damage located on the FWD end of the vessel’s keel along the steel worm-shoe. Repair fiberglass to the satisfaction of the attending CG MI prior to receiving credit drydock.
Action required: 705 - Other - as specified
Due 4 December 2025
Resolved 8 December 2025
Resolution: Sufficient photographic evidence of repairs received by Dispatch watchstander.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2025 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Vessel was missing 01 required portable fire extinguisher (size 2A) 46 CFR 176.810 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2025
Resolved 7 March 2025
Resolution: Vessel provided photo of a new fire extinguisher. Required 2A extinguisher, vessel owner purchased 3A:40-B:C extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 March 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing 03 required adult life jackets. Adult passenger count reduced to 50 passengers. 46 CFR 180.71(a) 705c
Action required: 705 - Other - as specified
Due 10 March 2025
Resolved 7 March 2025
Resolution: Vessel provided photos of new lifejackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 March 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Inspector observed penetrations through bulkhead between forward void space and engine room that was not watertight. Rectify within 7 days to the satisfaction of the USCG. 46 CFR 179.320(c) 705c
Action required: 705 - Other - as specified
Due 10 March 2025
Resolved 7 March 2025
Resolution: Vessel provided photos of firestop sealant added to the bulkhead penetration.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 March 2025 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel did not have Certificate of Inspection on board. Rectify within 7 days to the satisfaction of the USCG. 46 CFR 176.100(a) 705c
Action required: 705 - Other - as specified
Due 10 March 2025
Resolved 7 March 2025
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 3 March 2025 Resolved
All operator licenses required by this subpart must be readily available for inspection. Vessel did not have the Federal Communications Commission (FCC) Station License or the FCC Safety Radiotelephony Certificate on board and available for inspection. Rectify within 7 day to the satisfaction of the USCG. 46 CFR 80.175 705c
Action required: 705 - Other - as specified
Due 10 March 2025
Resolved 7 March 2025
Resolution: Provided photos of FCC certificate/station license
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 February 2024 Resolved
46 CFR 180.68 (a) A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. MI observed eleven distress signals that were expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2024
Resolved 21 February 2024
Resolution: Distress signals were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2024 Resolved
46 CFR 180.71(a) An adult life jacket must be provided for each person carried on board a vessel. MI observed 43 life jackets that were not serviceable. CODE 705: Vessel is restricted to carrying eight passengers that would require an adult size life jacket.
Action required: 705 - Other - as specified
Due 16 February 2024
Resolved 21 February 2024
Resolution: Life jackets were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2024 Resolved
46 CFR 180.71 (b) A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. MI observed 3 child size life jackets that were not serviceable. CODE 705: Vessel is restricted to carrying three passengers that would require a child size life jacket.
Action required: 705 - Other - as specified
Due 16 February 2024
Resolved 21 February 2024
Resolution: Life jackets were replaced.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 February 2024 Resolved
47 CFR 80.159 (e) (1) Radio operator must hold a marine radio operator permit or higher class license. Master of vessel during inspection did not have a radio operator permit or higher class license. CODE 705: Vessel must not operate with passengers beyond 1,000 feet from the nearest land at mean low tide unless a master with a marine radio operator permit or a higher class license is operating the vessel.
Action required: 705 - Other - as specified
Due 16 February 2024
Resolved 26 February 2024
Resolution: Received copy of marine radio operators permit.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 February 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 8 March 2024
Resolution: Received new station license.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 February 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 21 February 2024
Resolution: Purchased new first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 February 2024 Resolved
46 CFR 4.06-15 (a) (1) Marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. MI observed that alcohol test strips were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 29 February 2024
Resolution: Purchased new test strips.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 February 2024 Resolved
46 CFR 176.302 The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel could not locate the original copy of the COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 1 March 2024
Resolution: Mailed signed COI to operator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2023 Resolved
A flexible tube or hose may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump provided the hose or tube does not penetrate any required watertight bulkheads and is: (1) Of good quality and of substantial construction, suitable for the intended use; and (2) Highly resistant to salt water, petroleum oil, heat, and vibration. The engine room electric bilge pump was found with PVC piping installed between the pump and overboard valve. PVC piping is not permitted in vital system piping. 46 CFR 182.520(f)
Action required: 705 - Other - as specified
Due 8 March 2023
Resolved 9 March 2023
Resolution: Removed PVC piping that had been installed for the engine room electrical submersible bilge pump from the discharge of pump to the overboard discharge with new hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2023 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Conductors must be protected in accordance with their current carrying capacities. Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The conductor from the alternator to the switch panel is not protected by a fuse or breaker. The allowable ampacity of 8 AWG wire at 75 degC, outside of the engine room, is 65 amps. Provide a UL listed class T or CC DC rated fuse at 65 amps or less as primary branch protection. 46 CFR 183.380
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 27 March 2023
Resolution: The operator submitted new electrical plans to MSC that include a UL listed fuse as the primary branch overcurrent protection. The fuse is installed and the plans are under review by MSC.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 February 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline, such as a lazarette;A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The visual indicator for the bilge high water alarm was inoperable when tested. 46 CFR 182.530(c)
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 9 March 2023
Resolution: A new switch panel was installed at the helm. Witnessed proper operation of the audible/visual alarm for the high water and bilge pump operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. A vessel must be provided with bilge pumps in accordance with Table 182.520(a). The engine room bilge pump was not operational when tested. 46 CFR 182.520(a)
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 9 March 2023
Resolution: Witnessed proper operation of the electric submersible bilge pump for the engine room. Found the wiring for both posts on the back of the switch had corroded in to at the helm. Replaced switch panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 February 2023 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The starboard main engine RPM and oil pressure gauge were inoperable while the main engine was in operation. 46 CFR 182.410(b)
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 8 March 2023
Resolution: Gauge was repaired, wiring was corroded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2023 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The bladed fuses found in the 12V system are not permitted. Replace with UL listed cartridge type fuses. 46 CFR 183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2023
Resolved 8 March 2023
Resolution: Removed blade fuse and install new wire with cartridge fuse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 February 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. The starboard exhaust was found holed and leaking water in the lazarette space. The hole is located under the muffler. Make repairs to the satisfaction of the attending inspector. 46 CFR 176.700
Action required: 705 - Other - as specified
Due 27 March 2023
Resolved 9 March 2023
Resolution: Witnessed starboard main diesel in operation. Inspected fiberglass exhaust piping and non-metallic hose for any water leaking, no leaks found. Approximately 18" of fiberglass piping was replaced with new due to original piping being cracked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2023 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. The starboard shaft was found leaking water into the lazarette bilge at an excessive rate. Make satisfactory repairs to the attending inspector. 46 CFR 176.670
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 8 March 2023
Resolution: Corrected stern tube shaft packing by tightening packing gland.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The sea water pick-up valves for the main engine were unable to be cycled closed. Repair to the satisfaction of the inspector. 46 CFR 176.840
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 8 March 2023
Resolution: Valve and valve handle were lubricated and maneuverability was gained allowing valve to properly open and close.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (6) The opening in the hull for the pump discharge is placed as high above the waterline as possible;(7) A positive shutoff valve is installed at the hull penetration. The positive shutoff valve for the forward space bilge pump was found frozen in the open position. Replace like and in kind. 46 CFR 182.520(e)
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 8 March 2023
Resolution: Side shell valve was lubricated allowing for proper operation of the valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023 Resolved
A flexible tube or hose may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump provided the hose or tube does not penetrate any required watertight bulkheads and is: (1) Of good quality and of substantial construction, suitable for the intended use; and (2) Highly resistant to salt water, petroleum oil, heat, and vibration. The forward electric bilge pump was found with PVC piping installed between the pump and overboard valve. PVC piping is not permitted in vital system piping. 46 CFR 182.520(f)
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 8 March 2023
Resolution: Owner/Operator removed existing PVC pipe through the forward submersible electric bilge pump and installed new flexible hose from pump discharge to overboard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 February 2023 Resolved
Rail courses or the equivalent must be installed between a top rail required by paragraph (a) of this section, and the deck for a vessel on an excursion trip. Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). The rail course on the port quarter was found damaged and the space is larger than 4 inches. Repair like and in kind. 46 CFR 177.900(g)(1)
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 9 March 2023
Resolution: Inspected new cabling that was installed on both port and starboard stern railing - all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The main engine starting battery was found with an undersized conductor that was chafed and corroded. Replace the conductor with the previously approved size conductor and clean all corrosion areas to prevent resistance and heat build up. 46 CFR 183.200(b)
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 8 March 2023
Resolution: Replaced undersized conductor identified above with new.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 May 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of documentation currently in effect. MI found COD to be expired. 46 CFR 67.313(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2022
Resolved 4 May 2022
Resolution: Received confirmation email of submission to NVDC for COD for [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 May 2022 Resolved
For a life float – Approved under approval series 160.027. The color must be primarily vivid reddish orange. MI found 02 lifefloats to be damaged by the sun. Vessel is restricted to operations within 3 nautical miles of shore. 46 CFR 180.200 (a)(2) 46 CFR 160.010-4 (n)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 3 June 2022
Resolution: Lifefloats removed from vessel. Amended COI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2022 Resolved
All cable and wire must be installed with metal supports not more than 24 inches apart. MI found non-metallic supports being used in compartment beneath operating station. 46 CFR 183.340 (b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 3 June 2022
Resolution: Received photo of new metal supports installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. MI found no markings to indicate type and quantity for life jacket stowage. 46 CFR 185.604(f)
Action required: 10 - Deficiency Rectified
Due 3 May 2022
Resolved 3 May 2022
Resolution: Vessel representative labelled stowage locations with quantity and kind while MI on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 May 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. MI found first-aid kit to have expired ammonia inhalants and eye wash. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 6 June 2022
Resolution: Ammonia inhalants installed in vessel's first aid kit.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 May 2022 Resolved
A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151, 155, and 156. MI found vessel to not have a Garbage Management Plan and neither oil or garbage waste placards posted. 46 CFR 184.702
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 3 June 2022
Resolution: Plan written and onboard. Placards posted onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 May 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. MI found last drills logged to be November 2021. 46 CFR 185.520
Action required: 10 - Deficiency Rectified
Due 3 May 2022
Resolved 3 May 2022
Resolution: Vessel and crew completed drills with MI on board.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 May 2022 Resolved
Each EPIRB, other than EPIRB in an inflatable liferaft, must be tested monthly. MI found last EPIRB test entry to be November 2021. 46 CFR 185.728 (a)
Action required: 10 - Deficiency Rectified
Due 3 May 2022
Resolved 3 May 2022
Resolution: Vessel representative conducted EPIRB test while MI on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 May 2022 Resolved
Rail courses or the equivalent must be installed between a top rail and the deck so no open space exists that is more than 12 inches. MI found frayed wire coursing on port quarter. 46 CFR 177.900 (g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 3 June 2022
Resolution: Frayed wire replaced with new.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 February 2021 Resolved
Each vessel that operates on the high seas, or that operates beyond three nautical miles from the coastline of...must have on board a FCC Type Accepted Category 1, 406 MHz EQPIRB, installed to automatically float free and activate. Vessel's EPIRB battery found expired. Vessel is limited to navigation not more than 3 nautical miles from the nearest land. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 9 March 2021
Resolution: Vessel representative provided proof via e-mail of EPIRB registration.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 February 2021 Resolved
Each EPIRB...must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. No current records of monthly EPIRB testing were found. 46CFR185.728(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 9 March 2021
Resolution: Vessel representative provided proof of montly EPIRB tests for new installed EPIRB.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 13 May 2020 Resolved
46 CFR 182.455 (b)(3) Fuel lines must be protected from mechanical injury and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps. Fuel line for port engine was held up with plastic strap, replace with a metal support.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 18 May 2020
Resolution: Metal hanger installed to support fuel line.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2020 Resolved
46 CFR 184.710 A vessel must carry a first-aid kit under approval series 160.041 or a kit with equivalent contents and instructions. Iodine in kit was expired. Replace expired iodine with current medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 14 May 2020
Resolution: Operator purchased with required equipment for medical kit.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 May 2020 Resolved
46 CFR 04.6-3 The marine employer must ensure that the alcohol testing of each individual must be conducted within 2 hours of when the Serious Marine Incident occurs. Alcohol testing swabs were expired, replace with current swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 18 May 2020
Resolution: Valid alcohol test swabs purchased and installed on vessel.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 14 May 2019 Resolved
Safety Radiotelephony Certificate expired. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 18 June 2019
Resolution: Owner provided a valid Safety Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 May 2019 Resolved
Both life floats did not have water lights attached, retro reflective tape worn, and painter not connected/improperly installed. 46 CFR 180.175(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2019
Resolution: Water lights and painters correctly attached to life floats. Retro reflective tape replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2019 Resolved
Required 40-B:C extinguisher for machinery space found discharged. 46 CFR 181.500(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2019
Resolution: 40-B:C extinguisher replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019 Resolved
Exhaust hoses found single clamped instead of the required double clmap. 46 CFR 182.410(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 18 June 2019
Resolution: Exhaust hoses double clamped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019 Resolved
Fuel shutoff valve did not shut against the fuel flow for aft fuel tank. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2019
Resolution: Owner demonstrated correct operation of fuel shut off valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2019 Resolved
Lighting fixtures over the starboard and port MDE's not permanently affixed. 46 CFR 183.410(c)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 13 February 2020
Resolution: Vessel O/O uses removable lights to work on engines while moored, O/O will remove any non-permanent lights prior to operating underway.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2019 Resolved
Size and quantity of life jacket stowage markings worn. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 18 June 2019
Resolution: Life jacket stowage areas correctly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019 Resolved
Blow down lines for crankcase breathers running from engine space through the bulkhead into aft steering to the oil catch. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 18 June 2019
Resolution: Blow down lines contained within the engine room.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 27 April 2018 Resolved
Replace one missing 10-B:C portable fire extinguisher at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Operator purchased new portable fire extinguisher and placed onboard.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 April 2018 Resolved
Replace expired waterlight battery serviceing starboard side life float. Vessel restricted to daylight operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Operator purchased new batteries.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 April 2018 Resolved
Remove dead-ended wires in forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Operator removed wires.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 April 2018 Resolved
Replace missing guard for exposed hazard (fly wheel) on MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Operator installed wood shield IWO exposed hazard on MDE.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 27 April 2018 Resolved
Replace worn and missing name of vessel on stern, and port and starboard sides. Place hailing port on stern of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Operator applied new name and hailing port to hull as required.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 8 August 2017 Resolved
Make appropriate repairs to engine to the satisfaction of the attending CG marine inspector prior to carrying passengers IAW 46 CFR 176.700.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: Completed underway operational test of MDE.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 February 2017 Resolved
Replace 2 adult unserviceable PFD's. 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: Owner replaced PFDs; corrected on the spot.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 February 2017 Resolved
Provide radio with MMSI and GPS capability. 46 CFR 184.502.
Due 14 March 2017
Resolved 8 March 2017
Resolution: Operator purchased new VHF radio with GPS and programmed MMSI number into radio.
Lifesaving › Lifefloat › Markings
Issued 27 February 2017 Resolved
Stencil life float with capacity and vessel name. 46 CFR 160.010-8
Due 14 March 2017
Resolved 8 March 2017
Resolution: Verified name of vessel and capacity marked on life float.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 February 2017 Resolved
Provide proper first aid kit. 46 CFR 160.041-4.
Due 14 March 2017
Resolved 8 March 2017
Resolution: Operator replaced missing items.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 February 2017 Resolved
Replace missing coarse rail for hand rails near aft cleats. 46 CFR 177.900
Due 14 March 2017
Resolved 8 March 2017
Resolution: Operator replaced cable to provide proper course spacing.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 27 February 2017 Resolved
Make provisions to close engine room air supply ducts. 46 CFR 182.400.
Due 14 March 2017
Resolved 8 March 2017
Resolution: Operator is using dedicated rags in a bin labeled "Engine Room Vent Covers".
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 26 February 2016 Resolved
B-II fire extinguisher not charged. 46CFR181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2016
Resolution: Non-charged fire extinguisher replaced with fully charged extinguisher.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 February 2016 Resolved
4 life-jackets non-serviceable. Reduced passenger count to 45 passengers. 46CFR180.71(a)
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 8 March 2016
Resolution: 4 serviceable life-jackets provided.
Lifesaving › Lifefloat › Float-free Link
Issued 26 February 2016 Resolved
02 Lifefloat week links must be replaced of passenger count tags provided for each. Reduced route to no greater than 3 NM from shore. 46CFR180.137(b)(3)
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 8 March 2016
Resolution: 02 Lifefloat week links provided with passenger count tags. 3 NM Route restriction released.
Lifesaving › Lifefloat › Markings
Issued 26 February 2016 Resolved
Lifefloats must be labeled with vessel's name. 46CFR185.604(a)(2)
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 8 March 2016
Resolution: Lifefloats labeled with vessel name and passenger count.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 February 2016 Resolved
Must have a current Nautical Chart onboard. 46CFR184.420(a)(1)
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 8 March 2016
Resolution: Current Nautical Chart onboard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 February 2016 Resolved
Remove permanently installed extension cords in engine room and forward compt. 46CFR184.340(d)
Due 11 March 2016
Resolved 26 February 2016
Resolution: Removed extension cords.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 February 2016 Resolved
Install guards around engine's rotating belts. 46CFR177.960
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 8 March 2016
Resolution: Engine guards satisfactorily installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.