← All vessels
SAWYER
SAWYER is a passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in March 2026, along with 3 deficiencies.
Records from 2016 to 2026. Most recent: inspection, 18 March 2026.
- Built
- Not recorded
- Last inspected
- 18 March 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it2 - Simplified, Gross Ton
0 - Simplified, Net Ton
0 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
18 March 2026
Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8308021
7 April 2025
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8106745
27 March 2024
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7884895
3 April 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7671118
30 March 2022
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7424614
21 March 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412418
30 March 2021
In-Service Inspection · COI Inspection · Deadweight Survey · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7164954
22 July 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7072542
13 March 2019
Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6641778
21 June 2018
Deficiency Check · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6451472
23 March 2018
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6380722
17 April 2017
Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6155743
5 May 2016
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5869705
Deficiency record · 3
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 March 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
01 air leak was discovered during overpressure leak test:
- Starboard Sponson: middle top of chamber 2
46 CFR 177.100
JOINT CGD13/17INST 16711.1A 9.c.3
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 March 2022
Resolved
Vessel failed 125% overpressure test on starboard quarter compartment baffle. All inflatable chambers must be inflated in an alternating pattern to 125% of the manufacturer's working pressure to determine baffle integrity. The test shall last ten minutes.
46 CFR 176.610
Construction/Loadline › Hull › Hull Plating
Issued 21 June 2018
Resolved
Vessel has a failure in it's inflatable pontoon that can't be repaired. Vessel is ordering two new pontoons
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.