Tonnage as PSIX records it8620 - Convention (Subpart B), Gross Ton 4398 - Convention (Subpart B), Net Ton 12086 - Dead Weight, Metric Ton 17096 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 10
28 April 2026Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8356444
1 December 2025PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8274029
27 June 2023Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7724955
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 1 December 2025Resolved
OIL FUEL PIPES AND THEIR VALVES AND FITTINGS SHALL BE OF STEEL OR OTHER APPROVED MATERIAL, EXCEPT THAT RESTRICTED USE OF FLEXIBLE PIPES SHALL BE PERMISSIBLE IN POSITIONS WHERE THE ADMINISTRATION IS SATISFIED THAT THEY ARE NECESSARY. SUCH FLEXIBLE PIPES AND END ATTACHMENTS SHALL BE OF APPROVED FIRE-RESISTING MATERIALS OF ADEQUATE STRENGTH AND SHALL BE CONSTRUCTED TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED FUEL SETTLING TANK AND SERVICE TANK STEEL PIPING WAS REMOVED AND REPLACED WITH AN UNAPPROVED FLEXIBLE HOSES.
74SOLAS(09) II-2/4.2.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2025
Resolution: Received class report attesting to approved steel piping repairs and functional operation of the pipe drainage system.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 February 2017Resolved
0750- Means shall be provided to control leaks of flammable liquids. An active fuel leak was observed on a pipe from service #2 tank in purifier room. 74SOLAS14 II-2/4.1.1 50ac
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 2 March 2017
Resolution: Classification society submitted a report attesting to the replacement of a quick closing valve on tank #2. Following repairs, the fuek system was tested an found to operate satisfactorily.