SEACOR FEARLESS

SEACOR FEARLESS is a 2014 offshore supply vessel. The Coast Guard has recorded 14 inspections since 2016, most recently in March 2024, along with 8 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 4 March 2024.

Built
2014
Last inspected
4 March 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 March 2024
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9720897
WDH-2936
1175698
Flag
UNITED STATES
Maury page id
psix-1175698

Documentation record

Tonnage as PSIX records it1445 - Convention (Subpart B), Gross Ton
433 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

4 March 2024 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7873555
2 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7678978
27 January 2022 MTSA Verification · Internal Structural Exam · Drydock Exam · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7386669
1 March 2021 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7148474
9 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6984762
1 April 2019 Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6653641
7 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6621948
26 April 2018 Administrative Inspection · Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6400106
17 February 2017 Hull Examination · Administrative Inspection · Periodic Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6090495
2 February 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6082353
17 November 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6043867
31 August 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6001281
21 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5947949
15 June 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5908431

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 March 2021 Resolved
(a) Each enclosed space within the vessel must be properly vented or ventilated. Means must be provided for closing each vent and ventilator. Vessel's starboard generator supply vent louver was found inoperable. Vessel shall make repairs to the system and conduct an operational test in to the satisfaction of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2021
Resolved 2 March 2021
Resolution: Attended vessel and verified louver was repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2021 Resolved
46CFR4.06-15(a)(1) The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel's alcohol testing strips were expired and must be replaced. Alcohol strips found onboard vessel were expired. Vessel shall acquire sufficient number of alcohol strips to the satisfaction of Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2021
Resolved 2 March 2021
Resolution: Vessel purchased new alcohol test strips.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 17 November 2016 Resolved
Liquid mud tank valvers do not have remote shutoffs. Vessel may not carry oil-based liquid mud until valve remote shutoffs are installed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 December 2016
Resolved 2 February 2017
Resolution: Witnessed satisfactory operation of remote shutoffs.
Fire Fighting › Fire Pumps › Location
Issued 21 July 2016 Resolved
Space containing emergency fire pump has direct access to category "A" machinery space.SOLAS II-2 Reg 10/2.2.3.2.2.2 Alterations to be made prior to international voyage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Emergency fire pump has been relocated to the main deck, aft of the superstructure. The pump was tested from using two fire hoese from seperate hydrants and provided a pitot tube pressure at 38 psi to conform with SOLAS requirements.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 21 July 2016 Resolved
Emergency 208/120V switchboard is not easily accessible. SOLAS II-1 Regs 43.5.1 and 45.2 Alterations to be made prior to international voyage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: The emergency 208/120V switchboard was relocated to the main passageway, thus giving unrestricted access.
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 21 July 2016 Resolved
Emergency ventilation and fuel pump stops will not stop equip if damage to wiring occurs. Alterations to be made prior to operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: Under voltage trips were installed, and the emergecny stops for the ventilation and fuel pumps were tested satisfactorily to meet the requirements of 46 CFR 111.103-7.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 21 July 2016 Resolved
Emergency power cables run through category "A" machinery space and generator space. SOLAS II-1 Reg 43.1.3 Alterations to be made prior to international voyage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 22 September 2016
Resolution: Inspected in accordance with revised MSC plans for this vessel.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 July 2016 Resolved
General Arrangement/Fire Control plan must be updated. Alterations to be made prior to operation.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: Plan was updated and approved. Approval letter and stamped plans were provided to the vessel.