INTREPID SEAHAWK is a 2011 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in May 2020, along with 2 deficiencies and 2 operational controls.
Records from 2016 to 2020. Most recent: inspection, 25 May 2020.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19793 - Convention (Subpart B), Gross Ton 19753 - Regulatory (Subpart C or D), Gross Ton 6889 - Regulatory (Subpart C or D), Net Ton 6889 - Convention (Subpart B), Net Ton 25588 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
25 May 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6959987
20 May 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956442
20 May 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956485
5 March 2020PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6916816
3 March 2020Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6919918
16 October 2018COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6562150
9 August 2018COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6506077
8 May 2018Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6405128
25 April 2018Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6399505
19 October 2016COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6024960
18 October 2016Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6025242
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 8 May 2018Resolved
Fire fighter's outfits shall comply with the Fire Safety Systems Code. Personal equipment shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The PSCO discovered 02 fire fighting suits with holes and in an unservicable condition. 74 SOLAS (14) II-2/10.1.1 FSS Code Ch. 3.2.1.1.1 Code 40C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 May 2018
Resolution: Recieved proof of new fire suits being provided to the vessel.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 19 October 2016Resolved
0750-General arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions. Fire Control Plan requires "A" class doors between hydro power pack room and engine room. Doors currently "C" class doors with apparent modifications to frame. SOLAS II-2/15.2.4 40a,c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 October 2016
Resolved 25 April 2018
Resolution: Deficiency rectified to the satisfaction of the US Coast Guard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.