MAURY USCG vessel records
← All vessels

BILLIE

BILLIE is a 2011 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in May 2023, along with 6 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2016 to 2023. Most recent: inspection, 24 May 2023.

Built
2011
Last inspected
24 May 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2023
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9488047
1176701
Flag
LIBERIA
Maury page id
psix-1176701

Documentation record

Tonnage as PSIX records it12696 - Dead Weight, Ton
17972 - Displacement, Ton
9627 - Regulatory (Subpart C or D), Gross Ton
9627 - Convention (Subpart B), Gross Ton
4261 - Regulatory (Subpart C or D), Net Ton
4261 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

24 May 2023 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7695467
11 May 2023 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7683941
5 May 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7681702
2 March 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7401373
10 November 2021 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7345311
16 September 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7314027
10 September 2021 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7303900
9 February 2018 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6352443
7 February 2018 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6352676
20 December 2017 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6327622
6 December 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6316988
28 November 2016 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6045683

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 May 2023 No resolution recorded
SHIPS SHALL BE DESIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL, AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. PSCO OBSERVED SHIP'S NUMBER TWO GENERATOR INOPERABLE. 74SOLAS(04)II-1/3-1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 September 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. During the operational test of the rescue boat, the mechanical throttle linkage was damaged creating and unusable process for propulsion in deployed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2021
Resolution: Now the throttle was repaired by crew fixing with bolts, tested and found in order and working efficently
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 September 2021 Resolved
Fixed fire detection and fire alarm system installations shall be suitable for the nature of teh space, fire grouwh potential and potential generation of smoke and gas. PSCO's discovered smoke detectors in the FWD Bos'n stores that were affixed in a manner not designed for the full functionality w/ in the space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2021
Resolution: Now the fire detectors in fwd bosun store were properly fixed and installed and tested satisfactory. Fire detection alarm system expanded for testing and examined in the rest of the vessel (ER, galley, accommodation) and found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 September 2021 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services. PSCO's discovered approximately 18 emergency lights that were extinguished, in-operable, or not functioning correctly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2021
Resolution: Spares bulbs onboard replaced all the extinguished emergency lights (mainly on deck areas) and most of the normal lighting (except three normal lights). Emergency lighting considered satisfactory..
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2021 Resolved
The administration shall be satisficed that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. PSCO's discovered the starboard side navigation light was covered with duct tape to keep the unit weathertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2021
Resolution: Now with spare onboard, the stbd navigation light was replaced by a new type approved unit and tested and confimed installed satisfactory
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 10 September 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO's discovered irregularities in maintenance logs for the fire detection and e-lighting. ***Require external audit into the maintenance procedures outlined for fire detection and e-lighting***
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 September 2021
Resolution: The Flag is taking responsiblity as they will be issuing the inital ISM certificate to the vessel. Flag agreed to be verified and confirmed within the next 30 days

Ownership record