MAURY USCG vessel records
← All vessels

BALSA 88

BALSA 88 is a 2012 freight ship. The Coast Guard has recorded 30 inspections since 2016, most recently in September 2025, along with 8 deficiencies and 7 operational controls.

Records from 2016 to 2025. Most recent: inspection, 18 September 2025.

Built
2012
Last inspected
18 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9616034
1176724
Flag
PANAMA
Maury page id
psix-1176724

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded7
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it5698 - Convention (Subpart B), Gross Ton
10474 - Displacement, Metric Ton
7770 - Dead Weight, Metric Ton
2606 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 30

18 September 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8236650
13 August 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8209367
20 July 2025 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8187313
11 December 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7837693
2 May 2023 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7679266
2 May 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7679503
28 October 2022 COE-Dockside · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7583477
27 October 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7583513
25 October 2022 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7583520
26 August 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7544326
24 April 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7435571
26 December 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7372410
25 December 2021 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7372412
10 November 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7348635
7 November 2021 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7346801
5 July 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7245756
25 October 2020 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7081768
14 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6783468
9 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6777827
25 July 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6761656
9 March 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6638561
26 September 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6549148
22 August 2018 Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6525176
21 August 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6518830
26 February 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6361543
29 November 2017 Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6315121
10 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6284831
19 February 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6086729
22 February 2016 COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5815928
2 February 2016 Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806004

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 July 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed oil in the bilge of the freefall lifeboat. After testing the engine, 02 leaks were identified on the oil system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2025
Resolved 21 July 2025
Resolution: Class report received
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2025 Resolved
Each incinerator shall be approved by the Administration taking into account the standard specification for shipboard incinerators developed by the Organization. Incinerator walls are to be protected with insulated fire bricks/refractory. PSCO observed extensive damage to the incinerator's refractory.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2025
Resolved 18 September 2025
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2025 Resolved
Paint lockers shall be protected by a water spraying or sprinkler system. PSCO observed cans stored in the locker such that they would not be protected by the water spraying system.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 20 July 2025
Resolved 20 July 2025
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 25 July 2019 Resolved
PSCO observed excessive growth on the hull of the vessel. Master stated the growth was due to extended port call in Cuba from April 8-May 20, 2019 and provided documentation notifying company of the accumulated barnacles and marine growth. Company did not provide a response or direction on how to proceed. -33 CFR 151.2050(f)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 July 2019
Resolved 9 August 2019
Resolution: PSC NOLA received a Certificate of Completion from Max Diving Services satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 9 March 2019 Resolved
Fire-fighters outfits shall comply with the Fire Safety Systems Code. During the fire drill PSCO's observed fire fighting team without the lantern and ax as required by FSS Code.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 March 2019
Resolved 9 March 2019
Resolution: Deficiency Rectified - Vessel has required items on board and were added to the fireman's outifts.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 22 August 2018 Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must install and operate a ballast water management system (BWMS) that has been approved by the Coast Guard under 46 CFR part 162. The BWMS must be installed in accordance with §151.2035(b) of this subpart. Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. The vessel was found to have an inoperable ballast water treatment system.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 August 2019
Resolved 26 September 2018
Resolution: Received satisfactory class technician report attesting to repairs. Ballast water treatment system is currently operable. See documents.
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 29 November 2017 Resolved
The vessel failed to report to the COTP that their BWMS was inoperable prior to conducting cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 December 2017
Resolved 1 December 2017
Resolution: Vessel reported inoperable BWMS
Electrical › Electric Generation Source (emergency) › Generator
Issued 2 February 2016 Resolved
1430 -Auxiliary engines- Where the emergency source of power is a generator, it shall be started automatically upon failure of the main source of electrical power supply. PSCO noted the secondary battery bank failed to start, during initial spot checks of the emergency generator. SOLAS 74 am II-1/43
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 2 February 2016
Resolution: Ship's crew was able to identify and fix the emergency generator secondary start battery within a few minutes. PSCO was present upon repair and verified all modes of starting was satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.