ALABAMA is a 2012 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in May 2026, along with 53 deficiencies, 1 operational control and 1 casualty investigation in 2022.

Records from 2016 to 2026. Most recent: inspection, 22 May 2026.

Built
2012
Last inspected
22 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG5965
1176869
Flag
UNITED STATES
Maury page id
psix-1176869

Documentation record

Registered dimensions (L × B × D)35.7 ft × 13.8 ft × 5.0 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2012
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMARATHON, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

22 May 2026 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8378497
22 May 2026 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8380926
10 September 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8226463
29 May 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8130534
24 October 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8015960
5 January 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7845949
16 May 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7689434
9 May 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7684715
13 September 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7558535
22 July 2022 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7529035
1 June 2022 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465749
11 August 2021 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7283922
7 May 2021 COI Inspection · DAPI Audit · Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7191726
13 November 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6854533
8 May 2019 In-Service Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6674396
4 December 2018 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6589133
15 October 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6559807
16 October 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6288255
31 October 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6034743
25 October 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6012146

Deficiency record · 53

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2026 Resolved
Life jacket donning placard needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2026 Resolved
Water tight container holding flares needs to be mark as "DISTRESS SIGNALS'
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2026
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 May 2026 Resolved
01 Fire bucket is missing a lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2026 Resolved
Water tight container holding flares needs to be mark as "DISTRESS SIGNALS'
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 September 2025 Resolved
New SOLAS retro tape needs to be put on both life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 19 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2025 Resolved
Fire buckets need to be labeled properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 19 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 October 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 3 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2024 Resolved
Exhaust gas must not leak from the piping or any connections. Fix small exhaust leak on MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 3 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2024 Resolved
The marking must be an arrow pointing in the direction of the valve, and the words"FUEL SHUT OFF" must be in a color contrast with their background.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 3 December 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 October 2024 Resolved
Replace missing freeing port cover which allows water to quickly drain overboard water which has been shipped on exposed decks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 3 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2024 Resolved
A suitable hand tiller may be acceptable as the auxiliary means of steering. Demonstrate the method which is going to be used on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 3 December 2024
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 24 October 2024 Resolved
Provide Marine Inspector with a copy of a FCC operators license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 3 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2022 Resolved
Life float is faded and has several cracks. Make repairs/repaint life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 28 November 2022
Resolution: life float was repainted
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 September 2022 Resolved
First aid kit was missing several items. Must replace missing items to meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 5 October 2022
Resolution: New First aid kit meeting requirements on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 June 2022 Resolved
MDE dropped a valve. Make repairs and conduct MDE alarm tests and sea trials prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2022
Resolution: Repowered vessel and conducted satisfactory sea trials.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 May 2021 Resolved
Fixed fire extinguishing system is not working as designed. After activation, engine won't start after hitting overide switch. Conduct repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passsengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2021
Resolved 26 May 2021
Resolution: Tested system, operates as it should. cause of problem was Captain did not know how to use the system.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 May 2021 Resolved
1 fire bucket had holes in the bottom and missing 2 more fire buckets. Must replace broken/missing fire buckets with a minumum 2.5 gallon buckets, label properly and attach lanyards as required to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2021
Resolved 26 May 2021
Resolution: Vessel replaced all it buckets with 3 gallon. SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021 Resolved
1 fire extinguisher was found with a low charge. Must replace or recharge fire extinguisher to the satisfaction of attending CG Marine Inspector prior to carrying passengers. NFPA 10
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2021
Resolved 26 May 2021
Resolution: Vessel bought a brand new CG approved marine extinguisher
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Port side engine ventilation cover is broke and will not close in case of engineroom fire. Must make repairs and test the the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2021
Resolved 26 May 2021
Resolution: Vessel made a new vent guard, test SAT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 May 2021 Resolved
Anchor/mast light is not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers. COLREGS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2021
Resolved 26 May 2021
Resolution: Vessel replace entire anchor/mast light, test SAT
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 May 2021 Resolved
Vessel does not have a CG approved NAV chart onboard. Must have a CG approved paper NAV chart or have a digital NAV Chart that meets the requirements in NVIC 01-16
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: New CG approved NAV Chart onboard
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 May 2021 Resolved
Life float was found with several large cracks. Must make repairs and repaint with CG approved paint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: Repaired and repainted life float
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 May 2021 Resolved
Life float was found with faded/worn retro tape. Must replace all retro tape with CG approved SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: Replaced all retro tape with SOLAS
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021 Resolved
Ring life buoy floating light was not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector. Vessel is limited to day light hours only until repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 26 May 2021
Resolution: Replaced battery, test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021 Resolved
Life ring float light was missing the quick release corrosion resistant clip. Must replace missing clip and attach around the body of the life ring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 26 May 2021
Resolution: Bought and installed quick release clip
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021 Resolved
Life ring buoy retro tape was faded/worn. Must replace all retro on buoy with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: Replaced all retro tape with new SOLAS retro
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 May 2021 Resolved
First aid kit has missing items. Must replace missing items or get a new first aid kit that meets the 160.041 CG approval.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: Bought new first aid kit that meets CG Standards
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Fuel shut off valves need to be labeled. Must label emergency fuel shut off's properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: Labeled all 4 emergency fuel shut off valves.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 May 2021 Resolved
Engine guard was missing. Must replace missing guard on front of engine around pulleys/belts
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 26 May 2021
Resolution: Installed engine guard
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 May 2021 Resolved
Missing crew training log. Must have crew training log with all crew prior to getting underway for the first time and hold quarterly training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: Made new log books with proper entries
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 May 2021 Resolved
Missing Fire and MOB drill log. Must have log for drills and log entries properly as required. 46 CFR 185.520 & 185.524
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 17 June 2021
Resolution: Made new log books with proper entries
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2019 Resolved
Service all required fire extinguishing equipment by a qualified servicing technician. All fire extinguishing equipment was last serviced on October 2018.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2019
Resolution: Fire servicing company attended vessel and serviced all equipment.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 November 2019 Resolved
Replace/repair stern navigation light, light is inoperable and vessel is restricted from operating in reduced visibility conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2019
Resolution: New light installed and operable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2019 Resolved
Provide adequate means of separating child and adult PFD's in forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 December 2019
Resolution: PFD's placed in mesh bag.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 November 2019 Resolved
Vessel operator shall obtain FCC operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 December 2019
Resolution: Vessel operator provided proof.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 May 2019 Resolved
Provide original Certificate of Documentation (in progress).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 28 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 May 2019 Resolved
Provide valid State of Florida Certificate of Registration once vessel is documented.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 22 October 2019
Resolution: received
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 8 May 2019 Resolved
Provide MMC Medical Certificate for [name withheld].
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 20 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 May 2019 Resolved
Post all pages of newly issued COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 23 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 May 2019 Resolved
Provide appropriate charter/head boat fishing licenses for State and Federal Waters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 23 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 May 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 13 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2019 Resolved
Mount ring buoy so it is immediately available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 13 May 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 May 2019 Resolved
Provide PFD tending line for MOB per vessels emergency instructions.
Action required: 10 - Deficiency Rectified
Due 22 May 2019
Resolved 8 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 May 2019 Resolved
Provide a large scale navigation chart for the Marathon Area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 13 May 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 May 2019 Resolved
Provide a DSC VHF radio with a GPS chip or connect the DSC VHF radio to the vessels GPS navigation system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 23 May 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 May 2019 Resolved
Tighten steering brace as lag bolts have loosened over time.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 8 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2019 Resolved
Provide USCG approved bracket for one fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 23 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 May 2019 Resolved
Prove proper operation of fire detection system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 8 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2019 Resolved
Renew ring buoy floating electric light bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 8 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2019 Resolved
Mark fuel shut-off valve locations (two) with at least 1 " letters .
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2019
Resolved 13 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2019 Resolved
Renew 24" orange ring buoy due to rotted grab lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 13 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2019 Resolved
Correct PFD stowage location label to show 20 adult life jackets vs 18.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 8 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 May 2019 Resolved
Become familiar with and test vessels fire detection system in accordance with the manufacturer's instructions to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 23 May 2019

Casualty record · 1

22 July 2022Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 7529035
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.