MAURY USCG vessel records
← All vessels

BSA BURGLAR

BSA BURGLAR is a 2012 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in March 2026, along with 15 deficiencies and 2 casualty investigations between 2018 and 2019.

Records from 2016 to 2026. Most recent: inspection, 16 March 2026.

Built
2012
Last inspected
16 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN5965
1177025
Flag
UNITED STATES
Maury page id
psix-1177025

Documentation record

Registered dimensions (L × B × D)36.0 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2012
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portISLAMORADA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

16 March 2026 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8328851
20 August 2025 In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8203978
12 March 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8071758
28 February 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7871387
23 August 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7776380
1 March 2023 Annual Inspection · Examination of Repairs · Deficiency Check · Construction Oversight
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7643853
18 April 2022 Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7432958
8 September 2021 Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7307135
14 April 2021 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7175155
11 May 2020 Internal Structural Exam · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6955187
7 January 2020 Administrative Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6884051
6 June 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6746371
2 May 2019 Internal Structural Exam · Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6674817
22 June 2018 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6455766
23 March 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6666017
6 March 2018 DAPI Audit · Internal Structural Exam · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6665178
11 May 2017 DAPI Audit · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6144628
26 July 2016 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5955643
7 March 2016 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5825545

Deficiency record · 15

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 March 2026 Resolved
EPIRB monthly tests need to due logged and completed monthly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2026
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 March 2023 Resolved
Vessel is missing the VHF radio. Vessels must have a VHF radio. Replace missing radio and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 March 2023 Resolved
High water alarm light does not work. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2023
Resolved 3 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2022 Resolved
Life float cage webbing that attaches cage to float are dry rotted and torn. Make repairs to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 6 May 2022
Resolution: Attached new webbing to cage and life float
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 September 2021 Resolved
Cover for deck penetration for anchor chain was missing. Must replace missing cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2021
Resolved 18 October 2021
Resolution: Bought new cover and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 2 May 2019 Resolved
Replace and mark paddles with vessels name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2019
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2019 Resolved
Renew/Replace 03 life jackets. Capacity reduced to no more than 20 adults.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2019
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2019 Resolved
Mark stowage are with proper size and number.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: PFD stowage was properly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2019 Resolved
Replace expired first aid kit or expired content from kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: new first aid kit was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2018 Resolved
16 Adult and 02 child PFD's are wasted, and must be renewed. vessel can not carry more than 02 passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2018
Resolution: Renewed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 March 2018 Resolved
STBD navigation light is extinguished. Repair/Renew.
Action required: 705 - Other - as specified
Resolved 15 March 2018
Resolution: Renewed/Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2018 Resolved
Life ring is wasted and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2018
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2018 Resolved
Life float must be painted, repaired, and stenciled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2018
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 6 March 2018 Resolved
Life Float painter is not attached to the vessel. Attach with weak link.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2018
Resolution: Attached
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 July 2016 Resolved
internal foam was deteriorated and had lost significant bouyancy.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 26 July 2016
Resolution: New PFD was placed into service.

Casualty record · 2

22 June 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6455766
6 June 2019Routine · role: Involved in a Marine Casualty · activity 6746371
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record