MAURY USCG vessel records
← All vessels

SUNSHINE

SUNSHINE is a 2012 freight ship. The Coast Guard has recorded 7 inspections since 2019, most recently in September 2025, along with 3 deficiencies and 2 operational controls.

Records from 2019 to 2025. Most recent: inspection, 26 September 2025.

Built
2012
Last inspected
26 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9615028
1177168
Flag
LIBERIA
Maury page id
psix-1177168

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2019–2025)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it17019 - Convention (Subpart B), Gross Ton
10108 - Convention (Subpart B), Net Ton
28236 - Dead Weight, Metric Ton
34766 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 7

26 September 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8241718
15 July 2024 PSC B · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7950065
8 July 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7953137
7 July 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7952216
5 March 2020 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6921141
19 February 2020 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6911745
22 August 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6791368

Deficiency record · 3

14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 26 September 2025 Resolved
Every ship of 100 gross tonnage and above... shall carry a garbage management plan which the crew shall follow. PSCO observed used batteries which the crew identified as garbage stored in the ship's battery room instead of the garbage station. MARPOL V/10.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 September 2025
Resolution: Crew moved batteries to appropraite location per garbage management plan.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 26 September 2025 Resolved
For any vessel that is equipped with ballast water tanks and bound for ports or places in the United States... submit the ballast water report no later than 6 hours after arrival. PSCO observed vessel had not submitted the required ballast water report within 6 hours and was unfamiliar with the submital process.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 September 2025
Resolution: Vessel submited report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2024 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction and adequate for the service for which they are intended. PSCO observed jacket water leak on MDE cylinders #2 and #3. 74SOLAS(20), II-1/26, Prior to Movement, Code 60
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 July 2024
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.

Ownership record