MAURY USCG vessel records
← All vessels

EPIC BALI

EPIC BALI is a 2010 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in January 2026, along with 7 deficiencies and 4 operational controls.

Records from 2016 to 2026. Most recent: inspection, 15 January 2026.

Built
2010
Last inspected
15 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 January 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9519523
9V2988
1177208
Flag
SINGAPORE
Maury page id
psix-1177208

Documentation record

Tonnage as PSIX records it9506 - Displacement, Metric Ton
5296 - Convention (Subpart B), Gross Ton
6022 - Dead Weight, Metric Ton
1995 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

15 January 2026 COC-GAS Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8288707
13 January 2026 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8295962
19 July 2023 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7744719
23 May 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7694647
3 October 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7570365
19 June 2022 COC-GAS Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7480211
25 May 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7459342
26 December 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7372510
3 December 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7361990
18 October 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7335180
8 August 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7280828
6 July 2021 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7240892
5 March 2020 COC-GAS Annual · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6916577
5 March 2020 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6923320
25 March 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6648571
29 January 2019 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6613539
26 January 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6615367
27 May 2016 Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5884552
27 May 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5895014

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2022 Resolved
Spaces will be fitted with permadant gas sampling lines. It was reported that fixed gas detection is inoperable. Conduct repairs to SAT of Class. SOLAS 74 AM II-2/5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2022
Resolved 19 June 2022
Resolution: Received, reviewed and accepted class report from NKK attestting to the operational readiness of the ships remote gas detection system.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 June 2022 Resolved
All vessel will have access to immediate fire water. PSCO observed that vessel was not capable of producting emergency fire water without priming with main fire pump. SOLAS 74 AM II-2/10
Action required: 60 - Rectify deficiencies prior to movement
Due 21 June 2022
Resolved 23 June 2022
Resolution: Received, reviewed and accepted class report from NKK attesting to the operational readiness of the ships emergency fire pump.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 19 June 2022 Resolved
Insert gas for gas carrier. PSCO observed that engineers were not capable of demonstrating high O2 alarm on O2 generator demonstrate operational readiness prior to using. SOLAS 74 AM II-2/5
Action required: 705 - Other - as specified
Due 21 June 2022
Resolved 23 June 2022
Resolution: Recieved, reviewed, and accepted class report from NKK stating the deficiency was rectified. EFP has been overhauled/ repaired to include impeller drive shaft mechanical seal replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2020 Resolved
02108 - Electrical installations in general - A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least 02 generators. Vessel has 02 total generators and 01 is currently inoperative. 74SOLAS(14)II-1/41.1.1 - 60 ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 March 2020
Resolution: Received class report attesting to repairs
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 29 January 2019 Resolved
Incinerator walls are to be protected with insulated fire bricks/refractory and a cooling system. Outside surface temperature of the incinerator casing being touched during normal operations should not exceed 20 deg. C above ambient temperature. Incineratior does not close properly and does not protect crew from hot surface temperatures. MARPOL (2011 Cons.) Annex VI/16.6.1 and MEPC.76(40) 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 25 March 2019
Resolution: PSC HOU received Class NKK report attesting to proper repairs. Incinerator door gasket was replaced and the door was re-aligned for correct closure.
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 May 2016 Resolved
Vessel does not have working hot water in any space but the galley. Hot water has been inoperable since September, 2015.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 26 January 2019
Resolution: Deficiency rectified due to receipt of sufficient documentation attesting to installation of new and functioning calorifier.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 27 May 2016 Resolved
Vessel has 11 nozzles of the deck water spray system that are clogged and / or not spraying.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 27 May 2016
Resolution: Received class report attesting to the proper operation of the water spray system.

Ownership record