EPIC BALI is a 2010 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in January 2026, along with 7 deficiencies and 4 operational controls.
Records from 2016 to 2026. Most recent: inspection, 15 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it9506 - Displacement, Metric Ton 5296 - Convention (Subpart B), Gross Ton 6022 - Dead Weight, Metric Ton 1995 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
15 January 2026COC-GAS Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8288707
13 January 2026Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8295962
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2022Resolved
Spaces will be fitted with permadant gas sampling lines. It was reported that fixed gas detection is inoperable. Conduct repairs to SAT of Class. SOLAS 74 AM II-2/5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2022
Resolved 19 June 2022
Resolution: Received, reviewed and accepted class report from NKK attestting to the operational readiness of the ships remote gas detection system.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 June 2022Resolved
All vessel will have access to immediate fire water. PSCO observed that vessel was not capable of producting emergency fire water without priming with main fire pump. SOLAS 74 AM
II-2/10
Action required: 60 - Rectify deficiencies prior to movement
Due 21 June 2022
Resolved 23 June 2022
Resolution: Received, reviewed and accepted class report from NKK attesting to the operational readiness of the ships emergency fire pump.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 19 June 2022Resolved
Insert gas for gas carrier. PSCO observed that engineers were not capable of demonstrating high O2 alarm on O2 generator demonstrate operational readiness prior to using. SOLAS 74 AM II-2/5
Action required: 705 - Other - as specified
Due 21 June 2022
Resolved 23 June 2022
Resolution: Recieved, reviewed, and accepted class report from NKK stating the deficiency was rectified. EFP has been overhauled/ repaired to include impeller drive shaft mechanical seal replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2020Resolved
02108 - Electrical installations in general - A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least 02 generators. Vessel has 02 total generators and 01 is currently inoperative. 74SOLAS(14)II-1/41.1.1 - 60 ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 March 2020
Resolution: Received class report attesting to repairs
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 29 January 2019Resolved
Incinerator walls are to be protected with insulated fire bricks/refractory and a cooling system. Outside surface temperature of the incinerator casing being touched during normal operations should not exceed 20 deg. C above ambient temperature. Incineratior does not close properly and does not protect crew from hot surface temperatures.
MARPOL (2011 Cons.) Annex VI/16.6.1 and MEPC.76(40)
50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 25 March 2019
Resolution: PSC HOU received Class NKK report attesting to proper repairs. Incinerator door gasket was replaced and the door was re-aligned for correct closure.
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 May 2016Resolved
Vessel does not have working hot water in any space but the galley. Hot water has been inoperable since September, 2015.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 26 January 2019
Resolution: Deficiency rectified due to receipt of sufficient documentation attesting to installation of new and functioning calorifier.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 27 May 2016Resolved
Vessel has 11 nozzles of the deck water spray system that are clogged and / or not spraying.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 27 May 2016
Resolution: Received class report attesting to the proper operation of the water spray system.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.