Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it11627 - Convention (Subpart B), Gross Ton 21657 - Displacement, Metric Ton 16816 - Dead Weight, Metric Ton 5709 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
5 October 2024Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8014841
16 October 2022PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7573617
7 August 2017Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6227331
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 October 2022Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire... Starboard HFO tank shutoff valve was being kept open by a block of wood. When removed valve closes. Valve is not functioning as designed.
SOLAS 11-2/4.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2022
Resolution: Vessel completed repairs and sent documentation
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 7 August 2017Resolved
0735 - Ship's shall carry at least two fire-fighter's outfits. Crew could only provide one complete fire outfit. 74SOLAS(2014) Reg. II-2/10.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2017
Resolution: Vessel ordered new fire suits, invoice and picture attached to case.
Fire Fighting › Means of Escape › Blocked
Issued 7 August 2017Resolved
0960 - Escape routes shall be maintained in a safe condition. Emergency escape foor on second level of engine room could not open. 74SOLAS(2914) Reg. II-2/13.1.2
Action required: 705 - Other - as specified
Resolved 7 August 2017
Resolution: Corrected prior to team departing vessel.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.