Records from 2016 to 2021. Most recent: inspection, 28 January 2021.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 12
28 January 2021
Drydock Exam · Administrative Inspection
Physical examination · Activities Europe · Activity 7151911
14 May 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6952998
26 February 2020
Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 7019791
15 February 2019
COI Inspection · Administrative Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6615783
12 February 2019
Drydock Exam
Physical examination · Activities Europe · Activity 6617811
11 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6446452
14 March 2018
MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6371576
3 June 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6164439
29 March 2017
MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6113479
15 October 2016
In-Service Inspection
Physical examination · Activities Europe · Activity 6010280
5 May 2016
MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 5869336
14 January 2016
Drydock Exam
Physical examination · Activities Europe · Activity 5797154
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 15 February 2019
Resolved
Provide an update to SMS procedures to the USCG with regards to handing and documenting garbage transfered between vessels.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 March 2019
Resolution: Email was received with a change in policy to simplify and prohibit garbage from being collected from sister ships operating in the area to keep the garbage record book accurate.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 February 2019
Resolved
The master shall ensure the emergency lighting and power systems are tested at least one each week that the vessel is operated, to verify that they work. Vessel is currenlty testing E lights monthly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 March 2019
Resolved 5 March 2019
Fire Fighting › Firemans Outfit › Quantity
Issued 7 May 2018
Resolved
Firefighting outfits were stowed in the same location in the passenger area. Each outfit is required to be separated by at least one space IAW to SOLAS. Fire Control Plan needs to be updated to reflect change.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 June 2018
Resolved 7 May 2018
Resolution: Firefighting outfit was placed in deck locker with spare extinguishers. CG Inspector made an ammendment notation on the Fire Control Plan. New FCP will be submitted to reflect change.
Fire Fighting › Firemans Outfit › Axe
Issued 7 May 2018
Resolved
Firefighting outfits do not have axes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 4 June 2018
Resolution: Master provided pictures to CG of axes.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 May 2018
Resolved
Alcohol testing strips are expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 15 May 2018
Resolution: CAPT provided proof of procurement of Alcohol Testing Strips.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 14 March 2018
Resolved
Saline solution for eyewash stations in engine space and bow thruster room are expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 4 June 2018
Resolution: Master provided pictures to CG.
Lifesaving › Lifebuoys › Size
Issued 19 May 2017
Resolved
Bridge Life Buoys are not the correct size and weight.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 22 May 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 19 May 2017
Resolved
Provide required number of spare portable fire extinguishers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 22 May 2017
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 19 May 2017
Resolved
Correctly stow separate and secure lube oil and cleaning supplies in the bow thruster room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 22 May 2017
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 October 2016
Resolved
Provide documentation that the medical bed mattresses meet fire retardant ratings.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 25 January 2017
Resolution: Vessel provided documentation of fire retardant bed mattresses.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 October 2016
Resolved
Secure all equipment, desks, shelving, cabinets and medical beds.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 26 January 2017
Resolution: Vessel provided pictures of all items secured.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 15 October 2016
Resolved
Remove extension cords and power strips and install electrical outlets for electronic medical equipment.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 25 January 2017
Resolution: Vessel installed electrical outlets.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 October 2016
Resolved
Secure medical oxygen bottles.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 25 January 2017
Resolution: Vessel provided pictures of secured oxygen bottles.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 October 2016
Resolved
Update Fire Safety Plan for the alterations to include removal of the seats and addition of the hospital space. Vessel has submitted plans and they have been approved by class. CG needs to verify them at next inspection.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 17 May 2017
Resolution: Verified through 2017 annual exam of vessel.
Construction/Loadline › Structures › Door
Issued 9 May 2016
Resolved
Watertight doors not sealing properly. Adjust doors and rods to make watertight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 9 May 2016
Engineering › Freshwater Generation System › Piping
Issued 9 May 2016
Resolved
Reverse Osmosis overbaord pipe located starboard side is holed and allowing ingress of sea water. Repair/repair damage/corroded piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 7 June 2016
Lifesaving › Line-Throwing Appliances › Lines
Issued 9 May 2016
Resolved
Line Throwing Apparatus missing the auxilliary line (1,500 ft). Provide auxiliary line for Line Throwing Apparatus.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 26 September 2017
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 9 May 2016
Resolved
Two life buoys on bride wing missing float lights. Provide float lights for 01 deck Life Buoys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 23 July 2016