← All vessels
ALINDA
Freight Ship · Bulk Carrier class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named ALINDA
ALINDA is a 2012 freight ship. The Coast Guard has recorded 13 inspections since 2012, most recently in September 2026, along with 7 deficiencies and 1 operational control.
Records from 2012 to 2026. Most recent: inspection, 7 September 2026.
- Built
- 2012
- Last inspected
- 7 September 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9588378 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2751
1182455
Flag
MALTA
—
Maury page id
psix-1182455
Inspections, by type
…with no type recorded1
Years with a record
7 calendar years (2012–2026)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it42698 - Displacement, Metric Ton
35075 - Dead Weight, Metric Ton
12042 - Convention (Subpart B), Net Ton
22223 - Convention (Subpart B), Gross Ton
35075 - Dead Weight, Metric Ton
12042 - Convention (Subpart B), Net Ton
22223 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
7 September 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8485637
9 January 2026
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8293919
28 February 2025
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8086411
4 November 2024
PSC B · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8029009
4 October 2024
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8014286
4 October 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8014473
27 September 2023
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7798943
26 June 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7722701
18 June 2023
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7717577
2 November 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7080820
3 June 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5896014
5 June 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4335010
30 May 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4328262
Deficiency record · 7
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 November 2024
Resolved
THE FUNCTION OF FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS SHALL BE PERIODICALLY TESTED TO THE SATISFACTION OF THE ADMINISTRATION BY MEANS OF EQUIPMENT PRODUCING HOT AIR AT THE APPROPRIATE TEMPERATURE…OR OTHER PHENOMENA ASSOCIATED WITH INCIPIENT FIRES TO WHICH THE DETECTOR IS DESIGNED TO RESPOND.
PSCO OBSERVED CREW USING A LASER POINTER TO TEST FLAME DETECTORS INSTEAD OF PROPER EQUIPMENT LISTED IN SHIP’S TESTING PROCEDURES.
74 SOLAS (04) II-2/7.3.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 November 2024
Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. STRUCTURAL FIRE PROTECTION, INCLUDING FIRE-RESISTING DIVISIONS, AND PROTECTION OF OPENINGS AND PENETRATIONS IN THESE DIVISIONS.
PSCO OBSERVED UNAUTHORIZED HOLDBACKS ON CLASS A SELF CLOSING FIRE DOORS FROM THE ENGINE ROOM TO STEERING GEAR AND TO THE ESCAPE TRUNK FROM THE ENGING ROOM FLOOR.
74 SOLAS (20) II-2/14.2.1.1.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2024
Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE.
PSCO OBSERVED CLOSED VALVE ON SUPPLY LINE OF LOCAL WATER MIST FIRE SUPPRESSION SYETEM, MAKING SYSTEM UNAVAILABLE FOR IMMEDIATE USE.
74 SOLAS (20) II-2/14.2.1.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES, AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE WORKING CONDITIONS TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITIONS ON BOARD.
PSCO OBSERVED MULTIPLE LEAKS ON SEAWATER COOLING LINES AND TEMPORARY REPAIRS IN THE VICINITY OF PUMPS AND FRESH WATER COOLER.
74 SOLAS (04) II-1/26.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 November 2024
Resolved
IN MEETING THESE REQUIREMENTS THE COMPANY SHOULD ENSURE THAT INSPECTIONS ARE HELD AT APPROPRIATE INTERVALS AND ANY NON-CONFORMITY IS REPORTED WITH ITS POSSIBLE CAUSE, IF KNOWN.
PSCO OBSERVED MISSING QUARTERLY SAFETY INSPECTION, MONTHLY INSPECTION ITEMS RECORDED AS SATISFACTORY WHEN FOUND UNSATISFACTORY, AND ENGINE ROOM NON-CONFORMITIES NOT REPORTED TO COMPANY IN ACCORDANCE WITH SMS.
AN INTERNAL ISM AUDIT REPORT WITH CORRECTIVE ACTIONS SATISFACTORY TO THE OCMI SHALL BE SUBMITTED WITHIN 90 DAYS.
74 SOLAS (20) IX/3.1 & ISM Code 10.2.1 + .2
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 10 June 2016
Resolved
Fire-fighting appliances shall be properly tested and inspected. Various portable fire extinguishers throughout the vessel had not been inspected monthly as required by the vessel's fire-fighting maintenance plan.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 30 May 2012
Resolved
9900-Transfer Equipment Test-Crew could not provide proper documentation attesting to the vessel's bunker lines hydrostatically tested 1.5 times the maximum allowable working pressure. Provide documentation attesting to the vessel's bunkering lines being properly tested in accordance with 33CFR156.170 prior to bunkering in U.S. waters.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.