MAURY USCG vessel records
← All vessels

EBS 20

Built
2012
Last inspected
16 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 16 December 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2012–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1182521
Flag
UNITED STATES
Maury page id
psix-1182521

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2012
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portMEMPHIS, TN
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHEM 55 Tank Barge · MISLE 44601 · 29 April 2014 · activity 4848054CE-62 Tank Barge · MISLE 52057 · 29 April 2014 · activity 4848054

Inspection history · 22

16 December 2025 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8279956
17 December 2024 Periodic Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8048411
18 July 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8000592
28 December 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7840694
27 April 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7676636
4 October 2022 COI Inspection · Cargo Tank Internal · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7570405
7 December 2021 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7367051
18 December 2020 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7113708
14 November 2019 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6857584
12 December 2018 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6599797
10 January 2018 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6335573
29 November 2017 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6315023
24 October 2017 Internal Structural Exam · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6294146
25 January 2017 Deficiency Check · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6080287
11 January 2017 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6070422
3 March 2016 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5826360
19 November 2015 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5769447
14 January 2015 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5090343
29 April 2014 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4848054
14 January 2014 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4782893
20 June 2013 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4626822
17 September 2012 Administrative Inspection · Initial Construction-Excluding Oversight · MTSA Verification · Deficiency Check · Internal Structural Exam · Initial Certification · Hull Examination · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4443538

Deficiency record · 9

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 December 2023 Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be painted in the sequence of red/yellow/red. The width of the red bands must be .1 meter (.33 foot) and the width of the middle yellow band must be .8 meter (2.64 feet) and labeled with the word "VAPOR" painted in black letters at least 50.8 mm (2 inches) high. Vessels VCS line was painted improperly. Vessel shall paint VCS line IAW with CFR to the satisfaction of local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 January 2024
Resolved 11 January 2024
Resolution: Received a picture from vessel rep showing vapor line has been painted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 October 2022 Resolved
Cargo pump relief valves shall be tested at least once a year to determine that they function satisfactorily at the pressure at which they are set to open. Vessel did not have documentation or tag indicating that the relief valve had been tested. Conduct testing or provide documentation of testing to the satisfaction of an attending marine inspector. Vessel is not authorized to conduct cargo until deficiency is rectified. 46 CFR 35.35-70(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2022
Resolved 28 October 2022
Resolution: Relief valve tested and objective evidence provided
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 January 2017 Resolved
Conduct hose testing at 1.5 times MAWP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 1 February 2017
Resolution: Reviewed hose testing documentation
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 January 2017 Resolved
Verify pressure gauges are within 10% of actual pressrue.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 1 February 2017
Resolution: New prssure gauges were installed and calibration documentation reviewed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 January 2017 Resolved
Perperly label transfer hoses IAW 33 CFR 154.500.
Action required: 705 - Other - as specified
Due 12 February 2017
Resolved 1 February 2017
Resolution: New cargo hose placed on board and properly labeled, viewed documentation of hydro test.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 14 January 2014 Resolved
Notice of Intent (VGP) was not on board as required per 40 CFR 122.2. Provide evidence that the barge Notice of Intent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2014
Resolved 16 January 2014
Resolution: Owner/ Operator provided evidence of NOI via email. All Sat
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 14 January 2014 Resolved
Vessel did not have 1 month of Declaration of Insoection as required by 33 CFR 156.150. Provide evedence of DOI's collection on board the barge to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 February 2014
Resolved 16 January 2014
Resolution: Owner/Operator provided evidence of history of DOI''s being conducted. All Sat
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2012 Resolved
Prior to carrying cargo Cyclohexannone (CCH), amend Cargo Authority Attachment to include CCH and all intended cargoes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2012
Resolution: Rcvd updated CAA from MSC to reflect addition of CCH
Documentation › Markings/Placards › Warning Signs
Issued 17 September 2012 Resolved
Remove cargo signs and cards for Caustic Soda Solution (CSS), Dichlorobenzene (BDO), and any other cargo not authorized in the Cargo Authority Attachment.
Action required: 705 - Other - as specified
Due 21 September 2012
Resolved 16 November 2012
Resolution: Signage removed

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.