This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it158322 - Dead Weight, Metric Ton 81186 - Convention (Subpart B), Gross Ton 183786 - Displacement, Metric Ton 52259 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
31 August 2020COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7046617
24 January 2018COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6337429
12 January 2016Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-TVE Renew · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5792697
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 12 January 2016Resolved
0715-Detection-Fire fighting appliances shall be kept in good working order & readyily avaiable for immediate use. PSCO observed a smoke detector head near the cargo pump steam turbine with a plastic cover on it rendering the smoke detector inoperable. SOLAS II-2 Reg 4
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2016
Resolved 20 January 2016
Resolution: submitted corrective action plan and held additional training.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 12 January 2016Resolved
0799-Other-Maintenance, Testing and Inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. The crew could not provide proper testing procedures for testeing the smoke detection system. SOLAS II-2 Reg 4
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2016
Resolved 20 January 2016
Resolution: External audit conducted.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.