Records from 2017 to 2026. Most recent: inspection, 22 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
22 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8410201
19 November 2025
Administrative Inspection · Examination of Repairs · Damage Survey · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8270843
31 July 2025
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8199356
21 January 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8067484
29 August 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7991255
28 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7991196
16 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7982643
9 August 2024
Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7977794
19 September 2023
DAPI Audit · MTSA/ISPS Verification · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7840688
12 June 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7713476
13 September 2022
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7558133
9 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7285628
24 June 2021
Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7234391
17 December 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7113350
3 June 2019
Examination of Repairs · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6702211
26 February 2018
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6362394
14 February 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6360130
11 March 2017
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6110338
28 February 2017
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6085453
25 January 2017
MTSA Verification · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6076684
14 - Pollution Prevention › 143 - MARPOL Annex III › Other (MARPOL Annex III)
Issued 22 June 2026
No resolution recorded
Key personnel must complete training in 33CFR101.650(d)(2) by January 12, 2026.
Company does not have a CYSO and all key personnel have not yet completed the training as of this inspection.
33 CFR 101.650(d)(4)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 August 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 December 2025
Resolved
46 CFR 115.804(c)
(a)At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following:(c) Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems;
Marine Inspector observed burn marks and charring of the port generator and upon closer inspection, identified a hole in the crankcase. Objective evidence indicated there was a crankcase explosion and potential fire occurred. Marine Safety Unit St. Thomas did not receive notification of any marine casualty prior to this inspection. The crew was unable to provide any definitive answers surrounding the hole in the crankcase.
Provide repair proposal plan to local MSU St. [name withheld] in Charge, Marine Inspection for review and approval prior to conducting repairs.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 18 December 2025
Resolved 18 February 2026
Resolution: The prime mover was replaced. Wiring was disconnected and reconnected. Windings were cleaned. Satisfactorily optested power supply.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 December 2025
Resolved
46 CFR 115.810(a)(2)
(a)At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following:(2) Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system and detecting system to determine that the system is in operating condition.
Marine Inspector observed a visual alarm in the wheelhouse for the fixed fire-fighting system, indicating the engine room pre-engineered fire supression system was not in full operational status. After further inspection, Marine Inspector observed unauthorized solder repairs to the Fireboy system. After questioning the crew, a crew member stated he took the Fireboy bottle home to make solder repairs because a fire servicing technician was not available. Marine Safety Unit St. Thomas did not receive notification of any marine casualty prior to this inspection.
Provide third party fire servicing report to the MSU St. [name withheld] in Charge, Marine Inspection.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 18 December 2025
Resolved 18 February 2026
Resolution: Both Fire Boy's were replaced. Satisfactorily optested shutdowns and overrides.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 18 December 2025
Resolved 18 February 2026
Resolution: Annual third party servicing and inspection was completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 August 2024
Resolved
(a) An inspection is required before the issuance of a Certificate of Inspection. Such an inspection for certification is not made until after receipt of the application for inspection required by § 115.105 of this part.
(b) Upon receipt of a written application for inspection, the cognizant OCMI assigns a marine inspector to inspect the vessel for compliance with this subchapter at a time and place mutually agreed upon by the OCMI and the owner, managing operator, or representative thereof.
(c) The owner, managing operator, or a representative thereof shall be present during the inspection.
Vsl COI lapsed and is now expired.
Vsl owner/operator shall request inspection date with local Marine Inspectors and conduct satisfactory COI inspection prior to operating.
46 CFR 115.400(a)(b)(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2024
Resolved 9 September 2024
Resolution: Conducted COI inspection
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 August 2024
Resolved
A self-propelled vessel must meet the applicable requirements for main and auxiliary steering apparatus in subchapters F (Marine Engineering) and J (Electrical Engineering) of this chapter.
The main steering gear and rudder stock must be Capable of moving the rudder from 35° on either side to 35° on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed, and from 35° on either side to 30° on the other in not more than 28 seconds under the same conditions; operated by power when necessary to comply with paragraph (b)(2) of this section.
Loss of steering on port rudder was reported.
Determine root cause for loss of steering on port rudder and make necessary repairs to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2024
Resolved 30 August 2024
Resolution: The vessel was unable to determine the root cause of the port rudder steering gear failure. The rudder gear has remained functional during this time. The vessel will continue to monitor the port rudder steering gear.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2023
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. 01 missing child lifejacket from the designated storage location on the upper PAX deck. Replace as required.
46 CFR 117.71(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2023
Resolution: [name withheld] attended the vessel located in Red Hook Ferry terminal. Verification of this items was corrected and def cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI’s observed 09 lifejackets on the upper PAX deck that were no longer serviceable.Replace as required.
46 CFR 117.71(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2023
Resolution: [name withheld] attended the vessel located in Red Hook Ferry terminal. Verification of this items was corrected and def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 June 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew from electrical hazards. Bilge manifold compartment missing lights and covers.
46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2023
Resolution: [name withheld] attended the vessel located in Red Hook Ferry terminal. Verification of this items was corrected and def cleared.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 September 2022
Resolved
The following spaces must be equipped with fire detection and alarm systems of an approved type that is installed in accordance with part 76 in sub-chapter H of this chapter. Accommodation spaces, propulsion machinery spaces and control spaces. Attending MI's noted that the fire detection panel in the wheelhouse had active faults. When two smoke detectors where tested in the accommodation space no alarm sounded on the bridge. Prior to operations with passengers, clear all faults and restore the system to full operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2022
Resolution: Received a technican service report and video attesting to full operation of the fire detection system. Work order 2209-0547 Maritech Solutions [email withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2022
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following unmanned spaces: a space with a through hull fitting below the water line, machinery space, bilge well, shaft alley. Attending MI's noted that a nuisance alarm was continuously sounding when the bilge high water alarm panel was energized. System is to be restored to full operational capacity prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2022
Resolution: Verified correction by [name withheld], MSD St. Thomas on 14 Sep2022
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 13 September 2022
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations as set forth in 47CFR part 80. Attending MI's noted that the EPRIB annual certification was past due.
Action required: 10 - Deficiency Rectified
Resolved 13 September 2022
Resolution: A copy of the EPRIB Regisration was received and verified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 June 2021
Resolved
A vessel that is exposed to saltwater more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
The RED HOOK I is due for drydock examination no later than June 30, 2021. The vessel must undergo a credit drydock examination to the satisfaction of the USCG prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2021
Resolved 8 July 2021
Resolution: Vessel completed credit drydock exam.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 December 2020
Resolved
42 adult lifejackets removed from service due to sun-damaged torn fabric. Replace 42 adult lifejackets. Vessel passenger count limited to 161 until lifejackets are replaced.
Action required: 705 - Other - as specified
Resolved 21 December 2020
Resolution: New pfds provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2020
Resolved
Demonstrate bilge suction from forepeak and lazarette prior to receiving annual inspection credit.
Action required: 705 - Other - as specified
Resolved 17 December 2020
Resolution: Bilge pumps tested satisfactorily
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 December 2020
Resolved
Provide a correct written passenger count log.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2020
Resolved 17 December 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 December 2020
Resolved
Provided updated/ current Coast Pilot [name withheld], and Charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2020
Resolved 21 December 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 December 2020
Resolved
Provide updated drill log entries for man overboard, fire and abandon ship drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2020
Resolved 21 December 2020
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 June 2019
Resolved
EAP Placard missing.
Action required: 10 - Deficiency Rectified
Due 20 July 2019
Resolved 31 July 2019
Resolution: EAP Placard has been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 June 2019
Resolved
Emergency lighting appliance (2) inoperable due to discharged batteries.
Action required: 10 - Deficiency Rectified
Due 20 July 2019
Resolved 21 July 2019
Resolution: New lights installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 June 2019
Resolved
Vessel log book missing due to hurricane damages.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 July 2019
Resolved 31 July 2019
Resolution: Log has been replaced
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 February 2018
Resolved
PFDs not stored in convenient locations distributed evenly throughout the vessel. Most PFD's for upper deck were not in their location, but stored in a locker on main deck.
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Corrected on the spot
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 February 2018
Resolved
PFDs were not stowed in accordance with approved lifesaving equipment plan.
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Corrected on the spot
Personnel › Training › Safety Orientation
Issued 26 February 2018
Resolved
The vessel master was unaware of the location of the PFDs relocated form the storage locations on the upper deck.
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Corrected on the spot
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 February 2018
Resolved
The locker which the PFDs had been moved to was not marked with PFD quantities inside.
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Corrected on the spot
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 14 February 2018
Resolved
Determine cause of fire alarm panel faults and show proper operation.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 9 March 2018
Resolution: Manufacturer technician attended and diagnosed/repaired issues.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 February 2018
Resolved
Provide current navigation publications.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 21 February 2018
Resolution: Vessel sent evidence showing provision of current publications.
Lifesaving › Lifebuoys › Serviceable
Issued 14 February 2018
Resolved
Replace grab line on upper deck aft ring buoy.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 9 March 2018
Resolution: Replaced.
Engineering › Bilge Water Management System › Valve
Issued 28 February 2017
Resolved
Replace articulating fitting on port fwd compartment remote operated valve.
Action required: 705 - Other - as specified
Resolved 3 March 2017
Resolution: Fitting replaced.
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 February 2017
Resolved
Replace stbd fire/bilge suction valve and port generator suction valve.
Action required: 705 - Other - as specified
Resolved 3 March 2017
Resolution: Valves replaced.
Construction/Loadline › Hull › Hull Plating
Issued 28 February 2017
Resolved
Replace hole in stbd aft rub rail.
Action required: 705 - Other - as specified
Resolved 3 March 2017
Resolution: Vessel repaired hole.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 28 February 2017
Resolved
Repair cracked window on stbd side of passenger compartment.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 4 April 2017
Resolution: Vessel replaced glass.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 January 2017
Resolved
Show GPS input into DSC radios.
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 9 February 2017
Resolution: Vessel demonstrated input of GPS coordinates into DSC radio.
Fire Fighting › Fire Pumps › Pressure
Issued 25 January 2017
Resolved
Show proper operation of pilot house fire pump/fire main pressure gauge.
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 9 February 2017
Resolution: Vessel demonstrated operating pressure gauge.
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 25 January 2017
Resolved
IBA weak links not connected to painters.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: Corrected on the spot.