Records from 2016 to 2026. Most recent: inspection, 3 August 2026.
Inspection history · 59
3 August 2026
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8453342
2 February 2026
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8304043
23 January 2026
PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8299340
9 August 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8205833
22 July 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8191812
4 July 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8179170
3 July 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8173926
27 May 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8144973
26 May 2025
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8144336
23 March 2025
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8098107
7 October 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8015401
23 September 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8008475
1 September 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7994533
13 August 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979687
12 August 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979604
5 August 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7972878
2 August 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7972892
26 July 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7967542
8 December 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7833708
22 November 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7827334
19 November 2023
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7826952
13 July 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7741218
9 May 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7684331
9 May 2023
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7684377
19 April 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7671439
8 April 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7661659
6 April 2023
COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7661568
29 December 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7612998
29 December 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7613941
26 December 2022
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7612996
14 October 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6833577
19 May 2019
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6687477
5 November 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6574622
29 October 2018
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6570462
19 September 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6543813
24 September 2017
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6273597
1 September 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6256255
16 July 2017
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6210286
2 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6194036
31 March 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115871
10 February 2017
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6085893
3 November 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6034545
9 September 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5996660
27 August 2016
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5980796
26 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5984405
23 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5980734
13 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5971159
10 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5968134
29 July 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5957264
26 July 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5953321
16 July 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5942185
13 July 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5939074
18 June 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5910965
15 June 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5908248
3 June 2016
COE-Offshore
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5893782
3 June 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5896967
1 June 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5893671
28 February 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5823406
28 February 2016
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5823785
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 January 2026
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. THE SHIP'S FREE FALL LIFEBOAT IS NOT ABLE TO TURN COMPLETELY TO STARBOARD AND DOES NOT TURN WITHOUT EXCESSIVE INPUT FROM THE HELM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 January 2026
Resolved 23 January 2026
Resolution: VESSEL PROVIDED CLASS REPORT STATING LIFE BOAT STEERING WAS RECTIFIED.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 March 2025
Resolved
Fire-extinguishing appliances shall be readily available. The water mist auto mode is non-operational, vessel can only use manual mode. Issed 50ac 74SOLAS(20)II-2/10.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2025
Resolved 27 May 2025
Resolution: Vessel submitted correspondence with Flag State and [name withheld] attesting to the firefighting equipment.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 September 2024
Resolved
The opening below the lowest course of the guard rails shall be not more than 380 mm 15 inches apart. In the case of ships with rounded gunwhales the guard rail supports shall be placed on the flat of the deck PSCOs observed
1966 ILLC Part 1 Reg. 25 (3)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2024
Resolution: Recieved photo proof of fixed railing and recieved guidance to clear the def through the PSC CPO.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 August 2024
Resolved
The structure shall be subject to surveys. A minimum of two outside inspetions of the ships bottom during and five year period not to edceed 36 mos. PSCO observed drydock inspections dated Feb 2018 and Dec 2022.
74SOLAS(20)/I/10(a)(6)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2024
Resolved 13 August 2024
Resolution: Ship notified class/company of discrepancy in vessels drydock. Vessel recently changed owner and class. New class did not document missing inspection of ships bottom. Next drydock scheduled IAW IMO Convention.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 August 2024
Resolved
The rings, lines, letters shall be painted in a white/yellow color on a dark background. PSCO observed deck line was rusted and not clearly visible.
ICLL 05/Annex 1/Reg 8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2024
Resolved 13 August 2024
Resolution: Crew painted deck line white.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 1 September 2017
Resolved
1510 - Cargo ships of 3,000 gross tonnage and up shall be fitted with a VDR which may be a S-VDR. Vessel’s S-VDR is not operating as designed. - 74SOLAS(14)V/20.2.2 - 16ab
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 24 September 2017
Resolution: Verified Class Report attesting to rectification
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 September 2017
Resolved
0999 - Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Identified condensation dripping onto control panel for air conditioner and refrigeration units. 74SOLAS(14)II-I/40.1.3 - 16ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 24 September 2017
Resolution: verified class report attesting to rectification
Deck/Cargo › Ballast › Piping
Issued 1 September 2017
Resolved
0940 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Identified pin-hole leak in ballast water discharge line near port discharge valve. 74SOLAS(14)I/11A - 16ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 24 September 2017
Resolution: verified class report attesting to rectification
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 19 July 2017
Resolved
2550 - Maintenance of Ship and Equipment - Observed running hours and required maintenance forms M-110-A, M-110-B and M-110-C. Discovered that main engine and auxiliary engines 1 and 2 are well overdue for scheduled maintenance. Provide proposal or conduct overdue maintenance as per manufacturer's recommended interval hours for items listed on forms M-110-A, M-110-B AND M-110-C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2017
Resolution: Received report from vessel's company for preventative maintenance schedule. Reviewed and approved. See documents for further information.
Electrical › Electric Generation Source (service) › Generator
Issued 16 July 2017
Resolved
Amain source of electrical power of sufficient capacity to supply all of the services mentioned in 40.1.1 shall be provided. This main source of electrical power shall consist of atleast two generating sets. Vessel has only one generator operational and is using the emergency generator to offset the loss of the #1 auxiliary generator and shaft generator.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2017
Resolved 19 July 2017
Resolution: Repairs were made. Received class report and witnessed satisfactory test of generator. See documentation for report.
Lifesaving › Rescue Boat › Construction
Issued 16 July 2017
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Rescue Boat is not operational and needs to be replaced. 74 SOLAS (14) III/20.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2017
Resolved 22 July 2017
Resolution: Witnessed satisfactory launching and recovery of rescue boat and verified required equipment. Verified technician and class reports.
Electrical › Electric Generation Source (service) › Generator
Issued 3 November 2016
Resolved
1430 -Auxiliary engines- A main source of electrical power shall be provided and consist of at least two generating sets. The No. 1 auxiliary engine/generator is inoperable, leaving the No. 2 auxiliary engine/generator as the only remaining main source of electrical power for the ship. 74 SOLAS (Cons. 04) Ch II-1/Reg.41.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2016
Resolved 5 November 2016
Resolution: The No 1 Auxiliary Engine/Generator was repaired and load tested to the satisfaction of Bureau Veritas by Pantropic Power Service Co.