Tonnage as PSIX records it30016 - Displacement, Metric Ton 19379 - Dead Weight, Metric Ton 17644 - Convention (Subpart B), Gross Ton 6617 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 7
11 June 2025PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8156985
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 11 June 2025Resolved
Visually inspect the existing conditions and standard of maintenance of crew accommodation. Special attention should be given to... rodent and vermin control. PSCO observed several ants in the dry provisions. Crew treated the area with bug spray.
46 U.S.C. 70002, ILO-147 p39/1(b)
10c
Action required: 10 - Deficiency Rectified
Resolved 11 June 2025
Resolution: Crew sprayed area with bug spray.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 August 2019Resolved
07115 - Fire dampers, including their relevant means of operation, shall be tested in accordance with fire test procedures code. The port and starboard air supply damper to the engine room was unable to be closed by the chief engineer by both manual operation of the counterweight and pneumatic activation modes.
74 SOLAS(14) II-2/9.7.1.2
10c
Action required: 10 - Deficiency Rectified
Resolved 23 August 2019
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 August 2019Resolved
07126 - Means shall be provided to control the leaks of flammable liquids. PSCO observed the fuel filter for the main diesel engine was leaking diesel fuel at a rate of 5 drops per second. PSCO observed approximately 15 gallons of oil removed from the bilge pocket after the condition was shown to the chief engineer. Chief engineer said the leak was caused by the changeover from HFO to MGO.
74 SOLAS (14) II-2/4.1.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2019
Resolution: RECOGNIZED ORGANIZATION SUBMITTED A SATISFACTORY CLASS REPORT FOR REPAIR.