MAURY USCG vessel records
← All vessels

EAST BANGKOK

EAST BANGKOK is a 2012 freight ship. The Coast Guard has recorded 12 inspections since 2018, most recently in June 2024, along with 12 deficiencies and 4 operational controls.

Records from 2018 to 2024. Most recent: inspection, 10 June 2024.

Built
2012
Last inspected
10 June 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 June 2024
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2018–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9659490
HSB4914
1186704
Flag
THAILAND
Maury page id
psix-1186704

Documentation record

Tonnage as PSIX records it11367 - Convention (Subpart B), Net Ton
32475 - Dead Weight, Metric Ton
41112 - Displacement, Metric Ton
20218 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

10 June 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7956799
31 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7924459
26 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7920007
18 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7914496
18 May 2024 PSC A · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7914724
18 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7924272
17 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7913937
17 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7923144
2 May 2024 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7904843
28 May 2022 PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7453049
23 May 2022 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7446879
11 July 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6465510

Deficiency record · 12

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2024 Resolved
Loss of propulsion
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2024
Resolved 18 June 2024
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 20 May 2024 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part 1, so that all entries in the book appropriate to that operation are completed. PSCO observed discrepancy between the bilge tank recorded sounding on the 14th of May and current sounding of bilge tank conducted by [name withheld] was stated to be due to operations requiring transferring bilge contents to bilge tank. However no entries were made in Oil Record book for 06 days prior to PSC A. Oil Record Book audit required. MARPOL Annex I, Regulation 17.4-17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2024
Resolved 25 May 2024
Resolution: Received, reviewed and accepted class from NKK. Confirmed entry of bilge water had been made properly and gave training for oil record book entries.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed internal wiring external to the generators and zip tied next standing oil as well as heated metal on generator body. 74 SOLAS (09) II-1/40.3-17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2024
Resolved 25 May 2024
Resolution: Received, reviewed and accepted class from NKK. Rearanged electrical cables and set them neatly. Standing oil removed and cleaned
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2024 Resolved
Precautions shall be taken to prevent any oil that may escape from any pump, filter or heater from coming into contact with heated surfaces. PSCO observed areas of damage or missing lagging on pipes in oil purifying room and around and under under generators. 74 SOLAS (09) II-2/4.2.2.6.2-40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 May 2024
Resolved 25 May 2024
Resolution: Received, reviewed and accepted class from NKK. All damaged and missing lagging was replaced and installed properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 20 May 2024 Resolved
For ships constructed on or after 01 October 1994 the following requirements apply: Appropriate means of communication shall be provided from the navigation bridge and the engine-room to any other position from which the speed or direction of thrust of the propellers may be controlled. PSCO observed listed directory next to communications center in steering gear room did not match actual directory, limiting communication to bridge. Crew repaired during inspection. 74 SOLAS (09) II-1/37.2-10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2024
Resolved 20 May 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 20 May 2024 Resolved
The safety management system shall be maintained in accordance with the provisions of the International Safety Management Code. PSCO observed that the #3 generator which was under maintenance that was not routine maintenance was not tagged out in accordance with ships SMS code section 10.6.1 and was instead tagged as running. PSCO conducted training and crew rectified on spot. 74 SOLAS (09) IX/5-10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2024
Resolved 20 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 20 May 2024 Resolved
Obstructions on decks or in holds or accesses where personnel must work or pass which may cause them to slip, trip, or fall. PSCO observed an excess of scrap metal on deck from cargo operations completed 02 days prior to inspection. Crew cleaned deck prior to PSCO departure. ILO-147/PWSA 33 U.S.C 1223 (b)1-10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2024
Resolved 20 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 May 2024 Resolved
The capacity of there generating sets shall be such that in the event of any one generating set being stopped it will still be possible to supply those services necessary to provide normal operational conditions of propulsion and safety. PSCO discovered when generator #1 lost power generator #3 was unable to carry vessels electrical load, causing vessel to go dark. 14SOLAS(74) II-1/41.1.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2024
Resolved 26 May 2024
Resolution: Witnessed satisfactory test and load sharing capabiity with satisfactory class report.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 18 May 2024 Resolved
Where the emergency source of electrical power is a generator, it shall be capable of being automatically started and supplying the required load as quickly as is safe and practicable subject to a maximum of 45 seconds. C/E stated the emergenct generator started in 48 seconds. 14SOLAS(74) II-1/43.3.1.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2024
Resolved 26 May 2024
Resolution: Witnessed test of E-gen, run and provide power, upon loss of power within 24 seconds in addition to satisfactory class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2024 Resolved
Electrical installations shall be such that all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions will be ensured without recourse to the emergency source of eletrical power. PSCO observed the boiler distribution panel with multiple relays with burned out LED lights and melted resistors. 14SOLAS(74) II-1/40.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2024
Resolved 26 May 2024
Resolution: Relays were replaced and witnessed boiler shutdown test in addition to class report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 18 May 2024 Resolved
The company and the ship shall comply with the requirements of the ISM Code. Every company should develop, implement, and maintain a SMS which includes: instructions and procedures to ensure safe operation of the ship. PSCO discovered crew not using correct procedures for the shut down of the boiler. 20SOLAS(74) IX/3.1 ISM Code 1.4.2 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 May 2024
Resolved 25 May 2024
Resolution: Received, reviewed and accepted class from NKK. Boiler is in operation with auto control mode running the burner with auto stop and start
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 May 2024 Resolved
74SOLAS(2009) II-2/4.2.2.3.4 - 60ac Oil fuel pipes, which if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above situated above the double bottom shall be fitted with a cock or valve directly on the tank capable of eing closed from a safe position outside the space concerned in the event of a fire occuring in the space in which such tanks are situated. PSCO observed fuel quick closing valves for service generators No.2 and No.3 inoperable during test.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2024
Resolution: Received class report (attached to documents tab) stating actuation cables replaced and all 3 service generator quick closing valves were functionally tested.

Ownership record