Inspection history · 17
2 December 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8284179
12 July 2025
Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8187758
26 April 2024
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7900081
24 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7813757
1 September 2023
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7786228
17 July 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7745097
20 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7623296
29 September 2022
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7566063
31 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7470116
28 September 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7327182
9 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7308026
20 July 2020
Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7011348
1 April 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4827524
26 May 2011
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4039682
18 May 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2071202
16 June 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1820623
12 October 1999
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1122717
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port propulsion engine oil leak forward inboard. Repair as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2023
Resolved 15 August 2023
Resolution: Repaired all engine leaks
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 25 July 2023
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. On a new vessel, each pipe that contains vapor, gas, or liquid that has a temperature exceeding 150 °F (65.5 °C) which is within reach of personnel must be insulated where necessary or otherwise guarded to prevent injury. Exterior exhaust behind pilothouse missing insulation/guard. Install as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2023
Resolved 16 August 2023
Resolution: Protective lagging installed on exhaust pipe as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2023
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Pressure relief valves - Twice every 5 years, with no more than 3 years elapsing since last test. No documentation of pressure test/replacement. Test/replace as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2023
Resolved 15 August 2023
Resolution: Documentation was provided indicating that valves were replaced with new 9/2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 July 2023
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Stern hatch missing labeling. Label as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2023
Resolved 15 August 2023
Resolution: All watertight hatches properly labeled
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 July 2023
Resolved
A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”. Distress signals found in plastic bag.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 25 July 2023
Resolved 25 July 2023
Resolution: Distress signals placed in portable watertight container, clearly marked.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 7 September 2022
Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures. No health and safety plan meeting the requirements of 46 CFR 140 Part E onboard vessel. Vessel operator shall provide a copy of the vessel's health and safety plan meeting requirements listed in 46 CFR 140 to the OCMI. All deficiencies identified from this inspection shall be recorded and corrected IAW the health and safety plan to demonstrate compliance.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 29 September 2022
Resolution: Company documented non-conformities as required.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 September 2022
Resolved
Fuel shut off valves must be operable. Port, starboard, and generator fuel shut-off valves with mousing wire attaching the valve closure to the valve handle. Starboard fuel shut off valve was not turning at all. Install permanent attachments between valves and valve stems and ensure starboard valve operates when actuated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 29 September 2022
Resolution: Installed bolts to fasten remote assembly to valve handle and tightened all attachment points. Satisfactorily operated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 September 2022
Resolved
Master must ensure that all lifesaving equipment is ready for use at all times. Lights on two required life jackets were inoperable. Replace life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 29 September 2022
Resolution: Lights replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2022
Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least three feet securing the water light around the body of the lifebuoy. The lanyards on the vessel's two light fitted lifebuoys had the lights attached with a clip and the slack of the light line was wrapped around the end of the light. Remove light line clips and make off around the body of the lifebuoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 29 September 2022
Resolution: Lanyard made around body of lifebuoy
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 September 2022
Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. Stern hatch was found with no gasket. Install gasket on stern hatch to prevent water ingress into stern void.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 29 September 2022
Resolution: Stern hatch and seating assembly replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 September 2022
Resolved
Except as provided by paragraph (b) of this section, each navigation light must - (1) Meet the technical standards of the applicable Navigation Rules; (2) Be certified by a laboratory listed by the Coast Guard to the standards of ABYC A-16 (incorporated by reference, see § 183.5) or equivalent, although portable battery-powered lights need only meet the requirements of the standard applicable to them. Installed navigation lights have been modified with non-approved internals. Replace with approved navigation lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 29 September 2022
Resolution: Navigation lights replaced with approved types
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2022
Resolved
Portable fire extinguishers and semi-portable fire extinguishers must be inspected, maintained and tested in accordance with NFPA 10. Monthly checks of portable and semi-portable fire extinguishers are not documented. Document monthly inspections as required by NFPA 10.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 29 September 2022
Resolution: Company policy changed to mark inspection of fire extinguishers on installed tags.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2021
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. All lifejacket storage locations missing quantity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 16 October 2021
Resolution: Locations labeled as required
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2021
Resolved
ach lifebuoy on a towing vessel must: (1) Be approved under approval series 160.050 or 160.150; (2) Be capable of being rapidly cast loose; (3) Not be permanently secured to the vessel in any way; (4) Be marked in block capital letters with the name of the vessel; and (5) Be orange in color, if on a vessel on an oceans or coastwise route. Port pilothouse life buoy vessel name is coming off.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 18 October 2021
Resolution: Life rings labeled as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 September 2021
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Pressure vessel relief valve testing documentation not available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 16 October 2021
Resolution: Testing documentation provided as required.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 9 September 2021
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Emergency Fuel shutoff valves missing labeling and operating instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 16 October 2021
Resolution: Labeled as required.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 9 September 2021
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT HATCH - KEEP CLOSED”. All deck hatches missing labeling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 16 October 2021
Resolution: Labeled as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port main propulsion engine has exhaust leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 16 October 2021
Resolution: Exhaust leak repaired
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 September 2021
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Stern section of aft deck missing rails or equivalent protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 16 October 2021
Resolution: Railing installed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2021
Resolved
Navigation lights. Each navigation light must meet the following: (1) Meet the technical details of the applicable navigation rules. (2) Be certified by an independent laboratory to the requirements of UL 1104 (incorporated by reference; see 46 CFR 110.10-1) or an equivalent standard under 46 CFR 110.20-1. Portable battery powered lights need meet only the requirements of the standard applicable to those lights. (3) Be labeled with a label stating the following: (i) “MEETS _____.” (Insert the identification name or number of the standard under paragraph (d)(2) of this section to which the light was type-tested.) (ii) “TESTED BY _____.” (Insert the name or registered certification mark of the independent laboratory that tested the fixture to the standard under paragraph (d)(2) of this section). (iii) Manufacturer's name. (iv) Model number. (v) Visibility of the light in nautical miles. (vi) Date on which the fixture was type-tested. (vii) Identification of bulb used in the compliance test. Anchor light housing and bulb did not meet standards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2021
Resolved 16 October 2021
Resolution: New light installed as required.