CT LONGFORD

CT LONGFORD is a tank ship. The Coast Guard has recorded 14 inspections since 2012, most recently in November 2016, along with 13 deficiencies and 5 operational controls.

Records from 2012 to 2016. Most recent: inspection, 24 November 2016.

Built
Not recorded
Last inspected
24 November 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9393072 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1187895
Flag
MALTA
—
Maury page id
psix-1187895

Inspections, by type

…with no type recorded5
Years with a record 4 calendar years (2012–2016)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10303 - Dead Weight, Ton
6764 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

24 November 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6060973
24 October 2016 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6026964
22 October 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6027705
27 September 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6010846
20 September 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6005029
20 September 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6010525
30 August 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5986668
16 October 2015 Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5743141
12 May 2014 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4857210
7 May 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4852689
7 May 2014 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4852802
8 July 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4371393
6 July 2012 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4370043
29 June 2012 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4360833

Deficiency record · 13

Documentation › Logs/Records › Oil Record Book
Issued 24 October 2016 Resolved
Each completed operation shall be signed by the Officer of Officers in charge of the operations concerned and each completed page shall be signed by master of the ship. PSCO observed 22 unsigned pages in ships Oil Record Book dating from 22AUG16 to 17OCT16. Expanded exam related to this deficiency and did not find any signs of malpractice. MARPOL (2011) Annex I/ Reg. 17.4.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 October 2016
Resolution: During the exam, PSCOs arrived to the conclusion that ships crew were not involved in illicit activities related to the provisions of MARPOl Annex I.
Deck/Cargo › Ballast › Valves
Issued 20 September 2016 Resolved
Oil fuel pipes and their valves and fittings shall be of steel or other approved material. According to the vessel’s piping diagram, the gate valve for the bunker line should be made of a certified stainless steel. The gate valves on board the vessel are made of unapproved cast iron. Cite: 74 SOLAS (14) II-2/REG-4.2.2.5.1
Condition: Improper Installation
Action required: 703 - Prior to bunkering operations
Due 20 September 2017
Resolved 27 September 2016
Resolution: Recieved Class documents verifying the valves were made of proper materials.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 October 2015 Resolved
PSCO found the oily water separator to be inoperable; during an attempt to test the system, the 15 ppm alarm arrangement defaulted to an error code and the oil content meter was incapable of displaying the oil content. PSCO also noted multiple leaks from the upper gasket of the oily water separator. 73/78 MARPOL 2011 Annex I/Reg 14.6. Code 30ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2015
Resolved 20 October 2015
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 October 2015 Resolved
Ignition sources shall be restricted. PSCO found multiple leaks and accumulations of flammable and combustible liquids throughout the main engine room, steering gear room, and adjacent machinery spaces as well as excessive oily water mixture in the bilges. 74 SOLAS (04) II-2/4.1.4. Code 30ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2015
Resolved 20 October 2015
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 16 October 2015 Resolved
Tankers shall be equipped with at least one portable instrument for measuring flammable vapor concentrations with a sufficient set of spares. Suitable means shall be provided for the calibration of such instruments. Vessel did not have any means or ability to calibrate the portable gas detectors. 74 SOLAS (04) II-2/4.5.7.1. Code 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2015
Resolved 20 October 2015
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 October 2015 Resolved
PSCO found numerous missing, corroded & heavily deteriorated handrails throughout the exterior, including in way of the superstructure and the starboard gangway. 66 ICLL (88 consol.) Annex I/25(4). Code 50ac.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 30 August 2016
Resolution: Master provided proper Class Report of repairs effected to the corroded handrails.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 16 October 2015 Resolved
PSCO discovered that vessel did not submit a ballast water report prior to entering port. Additionally, PSCO noted that the ballast water records required by vessel's ballast water management plan were not being properly maintained. 33 CFR 151.2050(g), 33 CFR 151.2060(b). Code 40c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2015
Resolved 30 August 2016
Resolution: Master has been educated on BWM Practices attested by Class.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 October 2015 Resolved
Based upon Deficiencies 01, 02, 03, 04, and 05 identified during the course of this examination as well as with general lack of upkeep and maintenance of the vessel, enough objective evidence of non- conformities have been discovered to show the vessel is not fully implementing its safety management system; an external ISM audit is recommended. 74 SOLAS(14) IX/5, ISM Code 2.1 & 5.1.1. Code 50ac.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 30 August 2016
Resolution: Proper documentation provided attesting to Class attending vessel to review its safety management.
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 June 2012 Resolved
Vessel did not have the U.S. Coast Pilot or Inland Navigation Rules onboard. SOLAS 2009 V/27 (70c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 May 2014
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 30 June 2012 Resolved
Vessel is not maintaining ballast water logs. 33 CFR 151.2050(b) (70c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2013
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 30 June 2012 Resolved
Vessel's transfer hoses are not properly marked with MAWP and product service type. (70c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2013
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 30 June 2012 Resolved
Vessel's had three cargo tanks with readings above 8% content of oxygen inside them. Vessel stated they were not informed on what the oxygen level should be. Reviewed the vessel's procedures and found no documentation regarding the levels. (70c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2013
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 29 June 2012 Resolved
Vessel had missing port aft flange stud and the flange studs at port forward, starboard aft and forward were loose. (70c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2013

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.