Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it5651 - Convention (Subpart B), Net Ton 17294 - Dead Weight, Metric Ton 22882 - Displacement, Metric Ton 11885 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 11
8 July 2026PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8373139
21 May 2026Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8381920
5 August 2023Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7760670
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 August 2019Resolved
Before the ship leaves port and at all times during the voyage, all the life-saving appliances shall be in working order and ready for immendiate use. Free-fall lifeboat working intermitently. During testing, lifeboat experienced multiple failed starts and one instance of shutdown failure
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2019
Resolved 14 August 2019
Resolution: vessel sent in survey report documenting rectification of deficiency.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 June 2016Resolved
0750-Fire prevention-Fire doors in galley boundaries shall satisfy the following requirements: hold-back hooks not subject to central control station release are prohibited. PSCO observed galley boundary door tied back by unapproved means. SOLAS (am) II-2/9.4.1.1.5.4
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Issue was resolved to the satisfaction of the attending Coast Guard Marine Inspector
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.