Inspection history · 20
10 July 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8118757
22 April 2025
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8097084
6 May 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7874606
5 July 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7684550
25 April 2023
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7667391
13 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7424959
16 November 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7352531
16 September 2021
Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7314183
14 May 2021
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7184755
28 April 2021
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7179801
19 April 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7178312
16 July 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7019508
22 July 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6758851
11 July 2019
Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6746384
30 July 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6504797
10 August 2017
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6236897
7 June 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6168700
12 April 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6119911
1 October 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6016606
18 April 2016
COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5847202
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the
operating station to indicate a high-water level. MI
observed that the forward high-level bilge alarm visual
indicator light was not operable at the operating
station.
46 CFR 182.530(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 24 July 2025
Resolution: MI received video and pictures from vessel operator of the forward high-level bilge alarm visual indicator light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 July 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with
equivalent contents and instructions. For equivalent kit
the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid
kit must be easily visible and readily available to the
crew. The vessel did not have ammonia inhalants or analgesics medication readily available in the first aid kit on-board.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 22 July 2025
Resolution: MI received picture of ammonia inhalants or analgesics medication readily available in the first aid kit on-board.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 10 July 2025
Resolved
Licenses for ship stations in the maritime services will normally be issued for a term of ten years from the date of original issuance, or renewal. MI observed vessel’s FCC radio station license had been expired for over one year.
47 CFR 80.25
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 22 July 2025
Resolution: MI receiv a picture of vessel’s valid FCC radio station license.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 July 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed missing guard for starboard side main engine.
46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 22 July 2025
Resolution: MI received picture of guard for starboard side main engine.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 July 2025
Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate, or equivalent construction. MI observed three bulkhead penetrations: forward bulkhead in lazarette space port and starboard sides penetrations and one in forward bulkhead in engine room port side, were not filled completely to keep engine room vapor tight.
46 CFR 182.35-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 22 July 2025
Resolution: MI received pictures of three bulkhead penetrations: forward bulkhead in lazarette space port and starboard sides penetrations and one in forward bulkhead in engine room port side, were not filled completely to keep engine room vapor tight.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 July 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI observed that vessel was missing one of two portable battery lights on-board.
46 CFR 183.430
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 22 July 2025
Resolution: MI received picture of two portable battery lights on-board.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 July 2023
Resolved
A vessel on a limited coast wise route must carry six hand red flare distress signa; and six hand hand orange smoke signals. Vessel has only 4 red flares.
46 CFR 180.68
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 7 July 2023
Resolution: Received photographic evidence of the deficiency correction.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 July 2023
Resolved
Each vessel must be equipped with at least two operable portable battery battery lights. Vessel does not have any portable lights.
46 CFR 183.430
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 7 July 2023
Resolution: Received photographic evidence of the deficiency correction.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 April 2023
Resolved
Repair damaged area noted on the port rub rail.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 May 2023
Resolution: Operator sent photos via e-mail attesting to completed repairs on the port rub rail.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022
Resolved
Each life jacket must be approved in accordance with 160.055. Marine inspector discovered seven life jackets that were damaged and beyond their serviceable repair. Passenger count will be reduced to twenty two adults.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Received picture of seven life jackets procured.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 13 June 2022
Resolved
On a vessel of at least 26 feet in length a visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space. Marine inspector discovered high water level alarm in lazaret is not operating properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Received video of high water alarm in lazaret operating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that it meets UL 1113 Rated and permanantly mounted.
FWD Bilge and Machinery Space bilge pumps not mounted and not UL 1113 Rated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 27 May 2021
Resolution: Verified installation of approved UL rated submersible pumps. OPS Tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2021
Resolved
A Pre-Engineered fixed gas extinguishing system must automatically shut down engines within the protected space.
SSDG does not shut down upon fire boy activation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 27 May 2021
Resolution: Verified proper operation of Pre-Engineered fixed fire system automatic shutdowns of all Engines within protected space. OPS Tested SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 April 2021
Resolved
Worm shoe rotten mid ship. Cut to good wood and replace. Provide repair details.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 November 2021
Resolution: Received objective evidence of wormshoe repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021
Resolved
Both lower bearings show excessive play. Replace bearings.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2021
Resolution: Operator provided evidence that both STBD stern tube and strut bearings were renewed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2021
Resolved
Extension cord, missing outlet cover and dead end wires observed behind salon refrigerator. Remove unused wiring and provide outlet cover.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2021
Resolution: Discrepencies corrected. All appeared satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 April 2021
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel is overdue for their Certificate of Inspection. Vessel must complete a satisfactory COI Inspection and receive a valid COI prior to the carriage of passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2021
Resolved 14 May 2021
Resolution: Completed satisfactory COI Inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 July 2019
Resolved
A VESSEL ON A LIMITED COASTWISE ROUTE MUST CARRY SIX HAND RED FLARE DISTRESS SIGNALS AND SIX HAND ORANGE SMOKE DISTRESS SIGNALS. VESSEL ONLY HAD SIX RED HAND FLARES. PROVIDE ADDITIONAL SIX ORANGE SMOKE, OR AS ALTERNATIVE, SIX ADDITIONAL RED HAND FLARES.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 2 August 2019
Resolution: additional flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 July 2019
Resolved
THE NAME OF A VESSEL MUST BE MARKED OR PAINTED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH LIFEJACKET. 10 RECENTLY REPLACED LIFEJACKETS NOT MARKED PROPERLY. PROVE PROPER MARKING.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 2 August 2019
Resolution: markings put on new jackets.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2019
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) - Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for its annual inspection, and must conduct satisfactory inspection prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2019
Resolution: Completed annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 July 2019
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval on 30APR2019. Vessel required to undergo satisfactory drydock examination prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2019
Resolved 18 July 2019
Resolution: Conducted satisfactory hull exam.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 August 2017
Resolved
Overdue on Annual Inspection. Complete satisfactory annual inspection prior to sailing with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2017
Engineering › Bilge Water Management System › Pump
Issued 11 August 2017
Resolved
No bilge pump provided in engine space. Install & prove operational prior to sailing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2017
Communications › Alarms/Indicators › High Water Alarm
Issued 11 August 2017
Resolved
High water alarm no operating in accom space. Prove operational prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2017
Engineering › Bilge Water Management System › Pump
Issued 11 August 2017
Resolved
Port side laz-space bilge pump not operational. Prove operational prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2017
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 11 August 2017
Resolved
Hydrostatic release on IBA installed upside-down. Install correctly prior to beyond Lakes, Bays & Sound.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 August 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 August 2017
Resolved
Fuel shutoffs are operated using vise grips. Make mechanism for operating shut-offs permanent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 30 July 2018
Resolution: Satisfactorily operated remote fuel shutoffs.
Communications › Radio Communications › EPIRB
Issued 11 August 2017
Resolved
Hydrostatic release on EPIRB expired in January. Install new. Apply registration sticker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 July 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2017
Resolved
Electrical lines in laz space & engine compartment held up with plastic zip ties. Provide proper metallic wire hangers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 30 July 2018
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 11 August 2017
Resolved
Holding tank overboard discharge valve not locked. Provide lock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 August 2017
Stability › Weathertight Integrity › General
Issued 11 August 2017
Resolved
Glass broken on port side window in galley space.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 30 July 2018
Resolution: Sliding window was replaced.
Engineering › Bilge Water Management System › Pump
Issued 11 August 2017
Resolved
No portable pump provided for watertight compartnemnts w/ only one fixed bilge pump. Provide prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 August 2017
Resolved
No proof of enrollment or MIS report provided for Drug & Alcohol Program
Due 25 August 2017
Resolved 18 August 2017
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 April 2016
Resolved
Provide life jacket placard that is correct for life jackets carried on board
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 21 April 2016
Resolution: Proper placard in place.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2016
Resolved
Remove or secure dead end wires at operating station
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 29 April 2016
Resolution: Wires were removed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 18 April 2016
Resolved
Provide properly charged B1 fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 April 2016
Resolution: Corrected on the spot
Fire Fighting › Fire Bucket › Lanyard
Issued 18 April 2016
Resolved
Provide proper lanyard for 01 fire bucket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 April 2016
Resolution: Fixed on the spot
Fire Fighting › Fire Bucket › Stenciling
Issued 18 April 2016
Resolved
Provide proper label for for 01 fire bucket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 April 2016
Resolution: Fixed on the spot
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 April 2016
Resolved
Provide an additional 06 life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 April 2016
Resolution: Fixed on the spot
Lifesaving › Hand Flares › Marking
Issued 18 April 2016
Resolved
Properly mark emergency signaling device container.
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 April 2016
Resolution: Fixed on the spot