MAURY USCG vessel records
← All vessels

JERA

JERA is a freight ship. The Coast Guard has recorded 1 inspection in 2025, along with 1 deficiency.

Records in 2025. Most recent: inspection, 9 April 2025.

Built
Not recorded
Last inspected
9 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2025
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9610884
HSB8729
1190935
Flag
NETHERLANDS
Maury page id
psix-1190935

Documentation record

Tonnage as PSIX records it18893 - Convention (Subpart B), Net Ton
33312 - Convention (Subpart B), Gross Ton
57111 - Dead Weight, Metric Ton
67785 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

9 April 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8101894

Deficiency record · 1

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 April 2025 Resolved
The machinery, boilers and other pressure vessels,associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be son installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed the pressure relief valve for the jacket water heater plugged due to recent heat exchanger repair. Crew unplugged valve and provided maintenance record. 74 SOLAS (Amend.) II-1/26.1 10 c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 April 2025
Resolved 9 April 2025
Resolution: Ship's crew returned pressure valve to proper service condition by removing plug and connecting relief pipe to the satisfaction of attending PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.