Records from 2017 to 2022. Most recent: inspection, 3 March 2022.
Inspection history · 7
3 March 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7402380
28 February 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7403030
28 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7185120
11 March 2020
Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6923954
30 July 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6767165
26 July 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6762774
3 November 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6300149
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 3 March 2022
No resolution recorded
THE MASTER OWNER OPERATOR IN CHARGE OF A VESSEL EQUIPPED WITH BALLAST TANKS THAT OPERATES IN THE WATERS OF THE US MUST EMPLOY ONE OF THE BALLAST WATER MANAGEMENT METHODS: INSTALL AND OPERATE A BWMS APPROVED BY THE CG. FOLLOWING INSTALLATION THE BWMS MUST PROPERLY MAINTAININ ACCORDANCE WITH ALL MANUFACTURER SPECIFICATIONS. THE INSTALLED BWMS IS INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 March 2022
No resolution recorded
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS TO NOT CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED EXPOSED WIRING IN JUNCTION BOX LOCATED IN BOSN STORES.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 11 March 2020
Resolved
All life-saving appliances shall be in working order and ready for immediate use. the rescue boat was operational until it was placed in gear, at which time the engine stalled and was unable to operate. Crew was able to clean/repair the carburetor and PSCO witnessed satisfactory operation.
Solas 74 (14 CONS) III/20.2
17c
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2020
Resolved 11 March 2020
Resolution: Crew was able to clean/repair the carburetor prior to the completion of the exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 March 2020
Resolved
Rings, lines, and letters shall be painted in white or yellow on a dark ground or black on a light ground. The load line markings had significant rust, discoloring the lettering.
ILLC 66/88 Reg 8
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 20 March 2020
Resolution: Vessel sent pictures of the painted loadline.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 November 2017
Resolved
01-1541-EACH SEF PROPELLED VESSEL MUST HAVE A NAVIGATION LIGHT INDICATOR PANEL IN THE NAVIGATION BRIDGE TO CONTROL SIDE, MASTHEAD, AND STERN LIGHTS. THE SIGNAL LIGHT CONTROL PANEL IS CURRENTLY INOPERABLE.-46CFR111.75-17(b) - 60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 8 November 2017
Resolved 8 November 2017
Resolution: LIGHT WAS REPAIRED TO THE SATISFACTION OF THE COAST GUARD.