Records from 1990 to 2022. Most recent: inspection, 30 May 2022.
Inspection history · 51
30 May 2022
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7463426
29 May 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7463922
6 April 2022
Construction Oversight · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7408621
4 March 2021
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7146195
14 August 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7031631
17 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6941425
13 September 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6814998
29 August 2018
Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 6526604
29 August 2018
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6526663
29 August 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6528320
22 August 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6519380
25 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6399666
17 August 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6244379
21 June 2017
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6187056
4 April 2016
Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5846874
16 July 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4380847
21 May 2012
Deficiency Check · Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4317683
12 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4206273
2 April 2009
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3444697
8 July 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3261229
21 March 2007
Hull Examination · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2891893
26 April 2006
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2633673
5 August 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2452553
28 April 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2344740
19 July 2004
Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2146498
24 April 2003
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1791729
14 April 2003
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1772165
31 January 2003
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1737933
29 July 2002
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1653543
16 May 2001
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1399615
26 May 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1437731
4 June 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1106877
12 April 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1122727
10 April 1998
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 788405
18 June 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 776453
2 June 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 776451
24 October 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1161867
20 March 1996
Hull Examination · Inclining Experiment
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 884777
8 March 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1168748
25 July 1994
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 861699
15 June 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1423968
21 May 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1382575
4 May 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1382574
22 May 1992
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 959365
16 July 1991
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 937311
12 June 1991
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1321757
24 April 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1221920
30 May 1990
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 932140
22 May 1990
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 922170
4 May 1990
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1216850
30 April 1990
Inclining Experiment
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 926075
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 May 2022
No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel is restricted from carrying passengers or cargo until satisfactorily reinspected by an attending marine inspector.
46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2022 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 March 2021
Resolved
At each inspection for certification, the owner/operator shall be prepared to have the vessel ready to inspect all accessible parts of the hull. The steering gear space overhead frame is wasted. Draft plans to rectify the deficiency, get approval of plans, repair wasted wood and contact Coast Guard Inspections to clear deficiency.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 9 April 2021
Resolution: Made repairs. Inspected sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 March 2021
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds. Vessel's port ladder well rail does is loose and can not support 200 pounds. Meet all regulations for deck rails.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2021
Resolved 9 April 2021
Resolution: Made repairs. Inspected sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2021
Resolved
Each ring life buoy must be approved in accordance with 160.050; the grab line shall have a minimum breaking strength of 1,350 pounds. Ring buoy's grab line was frayed and could not support the required breaking strength. Meet regulations for ring life buoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 23 March 2021
Resolution: Replaced grab lines that satisfactory met regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021
Resolved
Each life jacket's retro reflective material must be marked and arranged as specified in IMO Resolution A.658
Reflective tape was not satisfactory. Replace retro tape
on identified life jackets onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 23 March 2021
Resolution: Replaced retro tape that satisfactory met regulations.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 September 2019
Resolved
A vessel must comply with the applicable requirements for any radio installations including certificates to be issued by the FCC, as set forth in 47 CFR part 80.
Safety Radiotelephony Certificate was expired.
***Vessel restricted to 1000 ft. from shore until rectified.***
Action required: 705 - Other - as specified
Resolved 17 September 2019
Resolution: Provided valid Certificate
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 September 2019
Resolved
A vessel must comply with the applicable requirements for any radio installations including certificates to be issued by the FCC, as set forth in 47 CFR part 80.
Operator unable to provide Marine Radio Operator Permit for crew on board.
***Vessel restricted to 1000 ft. from shore until rectified.***
Action required: 705 - Other - as specified
Resolved 17 September 2019
Resolution: Provided valid Certificate
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 September 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Items required to be in First Aid kit were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 15 October 2019
Resolution: Operator provided new first aid kit.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 13 September 2019
Resolved
The Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Operator unable to produce Stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 15 October 2019
Resolution: Operator posted stability letter.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 August 2018
Resolved
A pre-engineered fixed fire extinguishing system must be installed in accordance with the manufacturer's instructions. Provisions shall be made to prevent admission of air into space protected by fixed firefighting. Bulkhead between engine room and aft compartment had many holes in the bulkhead which would make the pre-engineered fire extinguishing system ineffective.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 5 September 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 22 August 2018
Resolved
Each ship transporting more than 6 passengers for hire must have onboard a marine operator with a valid marine operators permit. Provide a valid marine operators permit. 47 CFR 80.159 Vessel restricted to 1000ft from shore.
Action required: 705 - Other - as specified
Resolved 31 August 2018
Resolution: Received proof of valid marine operator's permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 August 2018
Resolved
Passenger vessels must have a stations license. Provide a valid FCC station license. 47 CFR 80.401 Vessel restricted to 1000 ft from shore.
Action required: 705 - Other - as specified
Resolved 5 September 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 August 2018
Resolved
All vessels must have navigation lights in accordance with COLREGS. Mast head light was not operating. 46 CFR 183.420 Vessel restricted to daytime operations
Action required: 705 - Other - as specified
Resolved 22 August 2018
Resolution: Replaced bulb and mast light observed operating
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 August 2018
Resolved
The scantlings, workmanship and arrangement of each vessel shall provide for safe operation of the vessel. The longitudinal on the port side extending the length of the deck in line with the hatches is cracked through at Frame 7 from the stern. Provide temporary repair to support the deck and provide repair proposal for permanent fix. 46 CFR 177.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2018
Resolved 4 October 2018
Resolution: Received satisfactory repair proposal. See documents for drawings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 August 2018
Resolved
A submersible electric bilge pump must have a positive shut off valve at the hull. No shut off valves were provided at the hull penetration for the submersible electric bilge pumps. 46 CFR 182.520(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 10 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2018
Resolved
A vessel must have a ring life buoy. The ring buoy was found to be deteriorated. 46 CFR 180.70(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 12 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2018
Resolved
Each child size life jacket must be stowed in a location marked and separate from adult life jackets. Adult and child life jackets were stowed together with no notable separation. 46 CFR 180.78
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 5 September 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 22 August 2018
Resolved
No marine employer shall employ an individual unless an individual passes a chemical test for that employer. One crewmember was hired based off drug testing from another company with no agreement in place between the companies. 46 CFR 16.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 31 August 2018
Resolution: Received Chemical Test Reporting Agreement for crew member enrolled under a different chemical testing consortium.
Documentation › Logs/Records › Logbook (official)
Issued 17 August 2017
Resolved
Maintain logs for MOB and fire drills, none onboard, Corrected on the spot 46CFR122.520.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 17 August 2017
Resolution: corrected on the spot.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 17 August 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 25 August 2017
Engineering › Bilge Water Management System › Pump
Issued 17 August 2017
Resolved
3. Prove proper operation of #2 bilge pump and float of #1 bilge pump (works manual); VSL has 3 onboard total, 46CFR182.520 by 24AUG17.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 25 August 2017
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 August 2017
Resolved
Have onboard tides and current tables by 24AUG17, 46CFR184.420.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 25 August 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 August 2017
Resolved
5. Repair FWD NAV light not working, corrected on the spot, 46CFR183.420.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 17 August 2017
Resolution: corrected on the spot, replaced light bulb.
Fire Fighting › Fire Bucket › Capacity
Issued 17 August 2017
Resolved
Have on board 3 fire buckets, VSL had 1, 46CFR181.610 by 24AUG17.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 25 August 2017
Construction/Loadline › Hull › Stiffener
Issued 17 August 2017
Resolved
Repair upper deck starboard side rail, no passengers on upper deck by 24AUG17, 46CFR177.900.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 25 August 2017
Engineering › Steering Gear System › Rudder
Issued 17 August 2017
Resolved
Adjust rudder packing or re-pack to slow flow by 24AUG17, 46CFR176.610.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 25 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 17 August 2017
Resolved
Make operational engine shut down for fire suppression system, corrected on the spot, 46CFR181.420.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 17 August 2017
Resolution: corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 June 2017
Resolved
Vessel stoped by USCG Station Boston for inoperable navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 17 August 2017
Resolution: CORRECTED
Documentation › Certificates/Documents › Stability Letter
Issued 12 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 44 PERSONS(PASSENGERS AND CREW)
Due 1 June 2012
Resolved 21 May 2012
Resolution: At owner''s request, issued new stability letter based on weight ratio calcs.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 21 March 2007
Resolved
Seal engine compartment better to contain extinguishing agent in space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2007
Resolved 2 May 2007
Engineering › Steering Gear System › Fastener
Issued 27 July 2004
Resolved
Replace bolt on steering housing
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 16 August 2004
Resolution: Bolt replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 July 2004
Resolved
Replace UV line on life ring.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 16 August 2004
Resolution: UV line replaced.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 27 July 2004
Resolved
Label upper deck w/appropriate number of passengers
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 16 August 2004
Resolution: Labeling completed.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 July 2004
Resolved
Appropriately label child life preserver stowage.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 16 August 2004
Resolution: Labeling completed
Communications › Radio Communications › VHF Radiotelephone
Issued 27 July 2004
Resolved
Provide radio operator's permit.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 28 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 July 2004
Resolved
Provide one additional child life jacket.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 16 August 2004
Resolution: Lifejacket provided.
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 April 2003
Resolved
Provide 1 additional Type 1 child PFD for a total of 5. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2003
Resolved 26 April 2003
Resolution: Received fax copy of invoice for new PFD.
Documentation › Certificates/Documents
Issued 24 April 2003
Resolved
Provide a current Safety Radiotelphone Certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Action required: 705 - Other - as specified
Due 24 May 2003
Resolved 24 July 2003
Resolution: Received fax copy of Safety Radiotelphone Certificate.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 April 2003
Resolved
Prove proper operation of radar.
Action required: 705 - Other - as specified
Due 24 May 2003
Resolved 26 April 2003
Resolution: Received fax verification of completion.
Construction/Loadline › Hull › Transverse Frame
Issued 14 April 2003
Resolved
Vessel owner to provide maintenance plan to inspect frames at turn of bilge on both sides and provide repair proposals and make repairs as needed, to be completed prior to the start of the 2004 season. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 28 April 2005
Resolution: Frames along the port after side have been sistered and are holding satisfactory. A closer examination of the starboard side was done including removal of sheathing for fastener inspection. 8 fasteners 2-1/2" bronze were pulled and found satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 April 2003
Resolved
Aft deck rail loose in way of the aft boarding gate. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2003
Resolved 7 July 2003
Construction/Loadline › Hull
Issued 14 April 2003
Resolved
Make proper repairs to rotted plank at bilge strake on port aft side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2003
Resolved 24 April 2003
Resolution: Examined and found satisfactory.
Construction/Loadline › Hull
Issued 14 April 2003
Resolved
Sister every other frame aft of Engine room bulkhead (those without floors) port and stbd side. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2003
Resolved 24 April 2003
Resolution: Examined and found satisfactory. Photos of sistered frames placed in vessel file.
Construction/Loadline › Hull
Issued 14 April 2003
Resolved
Prior to recieving credit drydock exam conduct underway test in presence of CG inspector.
Action required: 705 - Other - as specified
Due 28 April 2003
Resolved 24 April 2003
Resolution: Witnessed satisfactory underway exam.
Accommodation/Occupational Safety
Issued 16 May 2001
Resolved
Replace broken glass on upper deck.
Condition: Unknown
Due 30 June 2001
Resolved 24 April 2003
Resolution: Examined and found satisfactory.
Accommodation/Occupational Safety
Issued 16 May 2001
Resolved
Provide current copies of Tides & Currents and NAVRULES.
Condition: Unknown
Due 30 June 2001
Resolved 24 April 2003
Resolution: Examined and found satisfactory.
Fire Fighting
Issued 16 May 2001
Resolved
Prove proper operation of or replace in kind fire pump, hose, and nozzle prior to carrying passengers.
Condition: Unknown
Due 18 May 2001
Resolved 30 May 2001
Lifesaving
Issued 16 May 2001
Resolved
Provide emergency instruction and emergency broadcast placards.
Condition: Unknown
Due 30 June 2001
Resolved 24 April 2003
Resolution: Examined and found satisfactory.
Construction/Loadline
Issued 16 May 2001
Resolved
Make proper repairs to rails on upper deck to comply with rail point load test of 200 lbs.
Condition: Unknown
Due 30 June 2001
Resolved 24 April 2003
Resolution: Examined and found satisfactory.
Documentation
Issued 10 April 1998
Resolved
PRIOR TO OPERATING MORE THAN 1000 FEET FROM SHORE, PROVIDE A VALID FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Documentation
Issued 10 April 1998
Resolved
PROVIDE PROOF OF 1998 ENROLLMENT WITH THE MARITIME CONSORTIUM COVERING ALL HANDS.
Condition: Unknown
Due 23 April 1998
Resolved 23 April 1998
Documentation
Issued 18 June 1997
Resolved
PRIOR TO OPERATING MORE THAN 1000 FEET FROM SHORE, PROVIDE A VALID FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Lifesaving
Issued 18 June 1997
Resolved
PROVIDE A DISTRESS SIGNAL CONTAINER IN ACCORDANCE WITH 46 CFR 185.614.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Electrical
Issued 18 June 1997
Resolved
PROVIDE A PROTECTIVE GLOBE AND GUARD FOR THE LIGHT FIXTURE LOCATED IN THE LOWER CABIN.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Documentation
Issued 18 June 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE CHEMICAL TESTING REGULATIONS CONTAINEDIN 46 CFR PART 16.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Construction/Loadline
Issued 20 March 1996
Resolved
PROVIDE DOCUMENTATION ON YOUR FASTENER RENEWAL PROGRAM CURRENTLY IN EFFECT.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Engineering
Issued 20 March 1996
Resolved
RENEW THE FUEL TANK VENT LINE IN ACCORDANCE WITH 46 CFR 182.450.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 8 March 1995
Resolved
PATCH KEEL, AFTER END OF KEEL JUST ABOVE WORM SHOE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 8 March 1995
Resolved
EXPOSE SHAFT LOG IN ENGINE SPACE._x001C_
Condition: Unknown
Due 15 March 1995
Resolved 17 March 1995
Electrical
Issued 8 March 1995
Resolved
PROVIDE COVER FOR ELECTRICAL JUNCTION BOX FOR SALT WATER WASHDOWN PUMP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 8 March 1995
Resolved
REPLACE BILGE DISCHARGE HOSE TO AFTER ELECTRIC BILGE PUMP.
Condition: Unknown
Due 15 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 8 March 1995
Resolved
CLEAN OUT AND RE-CAULK BOTTOM TWO PLANKS AT BUT, MIDSHIP, PORT AND STARBOARD.
Condition: Unknown
Due 15 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 8 March 1995
Resolved
REMOVE STRAINERS, PORT SIDE, FOR INSPECTION.
Condition: Unknown
Due 15 March 1995
Resolved 17 March 1995
Navigation
Issued 15 June 1994
Resolved
PROVE PROPER OPERATION OF VHF-FM RADIO.
Condition: Unknown
Due 15 July 1994
Resolved 11 August 1994
Lifesaving
Issued 15 June 1994
Resolved
PROVIDE EMERGENCY HANDHELD LANTERN.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Documentation
Issued 15 June 1994
Resolved
PROVIDE DOCUMENTATION OF ENROLLMENT IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 15 July 1994
Resolved 11 August 1994
Fire Fighting
Issued 15 June 1994
Resolved
MAKE EXTINGUISHER BRACKET EASILY OPERABLE.
Condition: Unknown
Due 15 July 1994
Resolved 11 August 1994
Fire Fighting
Issued 15 June 1994
Resolved
REPLACE NONAPPROVED HALON EXTINGUISHER ON LOAN WITH APPROVED B-II TYPE EXTINGUISHER IN HOUSE.
Condition: Unknown
Due 15 July 1994
Resolved 11 August 1994
Lifesaving
Issued 21 May 1993
Resolved
PROVIDE A NEW WEAKLINK FOR BUOYANT APPARATUS.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 21 May 1993
Resolved
CONDUCT UNDERWAY DRILLS IN PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Navigation
Issued 12 June 1991
Resolved
MOVE NAVIGATIONAL RUNNING LIGHTS TO PROVIDE 01 METER VERTICAL SEPERATION BETWEEN SIDE LIGHTS AND BOW LIGHTS PRIOR TO JULY 12, 1991.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Engineering
Issued 24 April 1991
Resolved
INSTALL HOSE CLAMPS ON BOTH SIDES OF BILGE DISCHARGE LINE SPLICE IN VICINITY OF HEAT PUMP.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Accommodation/Occupational Safety
Issued 24 April 1991
Resolved
SUBMIT DRAWINGS OF NEW HOT WATER HEATER SUPPLIED BY MAIN ENGINE TO MSO_x001C_ FOR APPROVAL.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Engineering
Issued 24 April 1991
Resolved
REPLACE WORN HOSE FOR EXHAUST COOLING WATER INTAKE.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Lifesaving
Issued 22 May 1990
Resolved
PROVIDE USCG APPROVED WATER LIGHTS FOR RING BUOY AND BUOYANT APPARATUS PRIOR TO CARRYING PASSENGERS-FOR-HIRE AFTER DARK.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990