GEMI

GEMI is a 2014 offshore supply vessel. The Coast Guard has recorded 28 inspections since 2016, most recently in July 2026, along with 19 deficiencies and 3 casualty investigations between 2023 and 2026.

Records from 2016 to 2026. Most recent: inspection, 7 July 2026.

Built
2014
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9704283
WDH6311
1195763
Flag
UNITED STATES
Maury page id
psix-1195763

Documentation record

Registered dimensions (L × B × D)278.8 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 3,400 / net 1,426
ITC dimensions (L × B × D)278.8 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 3,400 / net 1,426
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1426 - Convention (Subpart B), Net Ton
3400 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

7 July 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8432156
5 July 2026 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8434376
13 February 2026 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8305889
1 October 2025 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8243735
29 July 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8197249
10 July 2025 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8179657
16 September 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8007777
12 July 2024 COI Inspection · Drydock Exam · Internal Structural Exam · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7956800
8 January 2024 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7846297
28 December 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7843224
26 December 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7847209
21 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7654168
14 September 2022 Cargo Tank Internal · Administrative Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7558257
28 June 2022 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7492346
2 December 2021 MTSA/ISPS Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7360952
12 January 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7123109
11 June 2020 Appeal · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6974315
21 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6957115
27 January 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6897295
7 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6884263
24 October 2019 MTSA Verification · Hull Examination · COI Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6841236
29 October 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6570561
10 July 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6474693
8 December 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6322883
5 October 2017 Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281288
3 October 2017 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281533
14 April 2017 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6126564
15 September 2016 ACP Annual Oversight · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6001846

Deficiency record · 19

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2026 Resolved
The owner or operator of an OSV shall make the vessel available for inspection by a marine inspector each time an accident occurs, or a defect is discovered that affects the safety of the vessel; or the effectiveness or completeness of its lifesaving, fire-fighting, or other equipment. The vessel experienced a failure of the port main engine due to #4 cylinder head overheating. Vessel will return to Port Fourchon to undergo repairs prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2026
Resolved 9 July 2026
Resolution: Received ABS and tech report stating repairs were completed.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 1 October 2025 Resolved
No person shall conduct an oil or hazardous material transfer unless a drain is closed by mechanical means. Small discharge containments around hose connection/vents on both port and starboard sides were missing or provided with non-mechanical means for closure. Mechanical means to close containment drains were obtained and put into place. 33 CFR 156.120
Action required: 10 - Deficiency Rectified
Due 1 October 2025
Resolved 1 October 2025
Resolution: Mechanical means to close containment drains were obtained and put into place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2024 Resolved
Marine Inspections identified multiple emergency remote fuel shut-off valves inoperable. Vessel is to rectify deficiency prior to departure. 46CFR56.50-60 {d) 3 (ii
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2024
Resolution: System bleed and tested infront of CG attending inspector
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2024 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Two dead end cable in tank farm overhead; STBD main diesel engine open per-heater control box; Faulty receptacle on STBD deck cargo rail.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 September 2024
Resolution: Verified on scene cables in tank farm secured in a junction box; pre-heater box block off plate; deck cargo receptacles replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 September 2024 Resolved
A main transverse watertight bulkhead may not have non-watertight penetrations below the bulkhead deck. Non-watertight penetration identified behind port MDE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 September 2024
Resolution: Penetration properly sealed
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 4 September 2024 Resolved
Equipment in support of the normal operation of the emergency power source includes, but is not limited to sound powered phones. E-generator room has a deteriorated sound powered phone cable. 46 CFR 112.05-5 (d)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2024
Resolved 23 September 2024
Resolution: Sound powered phone replaced
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 4 September 2024 Resolved
If the unloading of a substance of category Y or Z is not carried out in accordance with the Manual, a prewash shall be carried out before the ship leaves the port of unloading, unless alternative measures are taken. The vessel has consistently offloaded drilling mud and stated in their cargo record book that tank stripping did not occur. The Cargo Record Book instructs the master when tank cleaning occurs labeled under section E that a receipt must be obtained. There are no receipts on board of discharges of liquid mud residue cleaning to shore side facilities. MARPOL Annex II Reg. 13.7.1.2
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 4 September 2024
Resolution: Corrected on scene
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 September 2024 Resolved
Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan’s implementation to understand and follow the vessel’s BWM strategy and comply with the requirements of this subpart. The BWM plan states that a specific form shall be used and maintained for 2 years of each ballast water operation, however the crew is not using the provided form and not following the ship specific plan. 33 CFR 151.2050(g)
Action required: 10 - Deficiency Rectified
Resolved 4 September 2024
Resolution: Corrected on scene
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2024 Resolved
Machinery spaces of category A above 500m3 in volume shall, in addition to the fixed fire-extinguishing system requited in paragraph 5.1.1, be protected by an approved type of fixed water-basted or equivalent local application fire-extinguishing system, based on the guidelines developed by the organization. MSC.1/Circ. 1387 section 3.1.6 states “operating instructions for the system should be displayed at each operating position.” The fire control plan on board states the valves outside of the machinery space located in the passageway of the tank farm is a “remote release station” for water mist in the engine room. The instructions are not clear on how to operate the system and the control for the pump starting is located in the forward bow thruster room.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2024
Resolved 1 October 2024
Resolution: New instruction plaques installed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 December 2021 Resolved
Fire detection and fire alarm systems shall be kept in good working order. Fire detection panel shows a fault for the port engine smoke detector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2021
Resolution: Fault was corrected by technician and cleared to the satisfaction of attending ABS Surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 December 2021 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. The rescue boat engine would not start. 74SOLAS(20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2021
Resolution: The spark plug for the rescue boat engine is to be replaced and the engine tested to the satisfaction of the attending ABS Surveyor.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 2 December 2021 Resolved
Any ship of 400 gross tons and above but less than 10000 gross tons shall be fitted with oil filtering equipment. The oily water seperator was inoperable. 705 - Vsl shall not sail international unitl OWS is operable and IOPP valid.
Action required: 705 - Other - as specified
Resolved 11 January 2022
Resolution: Technition replaced bad sensor and certified OWS. ABS Surveyor witness test of OWS and endorsed IOPP for annual survey. MI accepts technition and ABS report as satisfactory evidence.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 January 2021 Resolved
Each embarkation station must be adequately illuminated by lighting supplied from the emergency source of electrical power. Observed two embarkation station lights out on the port side on e-power.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2021
Resolved 12 January 2021
Resolution: Verified by pictures of lights on.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 January 2021 Resolved
The means of control of any fixed gas fire extinguishing system shall be ready accessible and operable. The master shall ensure the appropriate tests and inspections of fire extinguishing equipment. Observed emergency generator room fixed CO2 control cylinder that is in need of recharge of control gas. (FSS Code 5.2.1.3.3 & 46 CFR 132.350(a))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2021
Resolved 12 January 2021
Resolution: Verified by pictures of new control cylinder.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 December 2019 Resolved
Fire doors on 01 deck did not self-close as required by 74 SOLAS 14 (Consolidated) Chapter II-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2019
Resolved 3 December 2019
Resolution: Fire doors properly close.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 December 2019 Resolved
An illuminated magnetic steering compass, that can be read at the vessel's main steering stand, was not present. 74 SOLAS 14 (consolidated)/Chapter V, Regulation 19.2.1.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2019
Resolved 7 January 2020
Resolution: Magnetic compass light repaired and mirrors in tube cleaned
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 2 December 2019 Resolved
Vessel did not have Cargo Securing Manual available for inspection. 74 SOLAS 14/Chapter VI/Regulation 5.6
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 3 December 2019
Resolution: Vessel found Cargo Securing Manual, with ABS approval stamp.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2019 Resolved
Vessel did not have Ballast Water Management Plan, ballast water treatment system approval letter or ballast water records.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 27 January 2020
Resolution: Vessel rep submitted copy of ballast water recordkeeping log entry.
Electrical › Electric Generation Source (service) › Generator
Issued 14 April 2017 Resolved
Provide proper repairs to port shaft generrator
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 19 April 2017
Resolution: ABS Rep inspected and test ran stbd shaft generator.

Casualty record · 3

26 December 2023Routine · role: Involved in a Marine Casualty · activity 7847209
16 September 2024Routine · role: Involved in a Marine Casualty · activity 8007777
5 July 2026Routine · role: Involved in a Marine Casualty · activity 8434376
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.