MAURY USCG vessel records
← All vessels

BOAT

BOAT is a 1972 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in June 2026, along with 8 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 30 June 2026.

Built
1972
Last inspected
30 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCL4921
119577
Flag
UNITED STATES
Maury page id
psix-119577

Documentation record

Registered dimensions (L × B × D)55.0 ft × 16.0 ft × 4.5 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS CRAFT · HOLLAND, MI, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAUGATUCK, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57000 - Dead Weight, Ton
26 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

30 June 2026 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8420349
4 June 2026 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8381616
28 May 2026 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8382741
21 May 2025 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8139940
5 June 2024 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7922430
12 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7877387
23 May 2023 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7696293
2 June 2022 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7471820
25 May 2021 COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7200885
2 June 2020 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6966917
14 May 2019 Periodic Inspection · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6685813
16 April 2019 Deficiency Check · Drydock Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6669742
25 May 2018 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6423308
25 May 2017 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6177779
26 May 2016 COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5880346

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 June 2026 Resolved
Vessel on Great Lakes routes must carry (6) red and (6) orange flares. Vessel has (7) flares. Vessel restricted to LBS/R Routes.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2026
Resolved 5 June 2026
Resolution: New flares on board vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 4 June 2026 Resolved
Vessel requires anti-septic burn preparation in first-aid kit. None found.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2026
Resolved 5 June 2026
Resolution: Burn cream on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2026 Resolved
Connections to battery terminals must be permanent type. Connectors have wingnuts.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2026
Resolved 5 June 2026
Resolution: Permanent connectors installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 May 2025 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel COD was expired, provide valid COD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2025
Resolved 22 May 2025
Resolution: Provided valid copy of COD.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2020 Resolved
CO2 cylinder for fixed extinguishing in engine room is due for hydrostatic testing.
Action required: 705 - Other - as specified
Due 1 July 2020
Resolved 23 June 2020
Resolution: Hydro Completed by Rapid Fire Protection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2019 Resolved
CO2 cylinder for fixed extinguishing in engineroom is due for hydrostatic testing.
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 23 June 2020
Resolution: Hydrostatic test completed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 May 2017 Resolved
Vessel did not have Radio Op permit
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 1 June 2017
Resolution: O/O provided proof of permit.
Lifesaving › Lifebuoys › Serviceable
Issued 25 May 2017 Resolved
Lifebouy did not have reflective tape
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 1 June 2017

Ownership record