Records from 2001 to 2026. Most recent: inspection, 26 June 2026.
Documentation record
Registered dimensions (L × B × D)382.2 ft × 99.8 ft × 20.0 ft
Registered tonnagegross 340 / net 340
ITC dimensions (L × B × D)382.2 ft × 99.8 ft × 20.0 ft
ITC tonnagegross 5,805 / net 1,741
BuilderBOLLINGER MARINE · AMELIA, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 April 2026 · expires 30 April 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5805 - Convention (Subpart B), Gross Ton
340 - Regulatory (Subpart C or D), Gross Ton
1741 - Convention (Subpart B), Net Ton
340 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
26 June 2026
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8416596
6 February 2026
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8308029
8 April 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8106641
25 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7857889
1 August 2023
In-Service Inspection · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7754686
6 February 2023
COI Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7627493
20 January 2023
Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7628239
2 July 2013
Uninspected Other
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4638496
14 June 2013
Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4620407
4 March 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4258806
11 August 2010
Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3821522
17 April 2008
MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3186099
14 August 2006
MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2747664
28 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2727870
17 January 2006
MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2566649
5 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2326966
21 December 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2263033
27 April 2004
MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2054370
16 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2025712
27 February 2004
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2014559
17 September 2003
Re-Inspection · MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1907211
25 June 2002
COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1636057
17 June 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1632265
23 October 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 769198
11 October 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 191196
30 July 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1069576
29 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065047
18 April 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062145
18 April 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062146
9 March 2001
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450596
9 February 2001
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373312
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2024
Resolved
Specific tests and inspections shall be made by the inspector.For marine engineering equipment see subchapter F, for electrical Engineering equipment see subchapter J. A new 100KW Generator was installed replaced a 42KW, test installation to satisfaction of attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 25 March 2024
Resolved 27 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2024
Resolved
Specific tests and inspections shall be made by the inspector.For marine engineering equipment see subchapter F, for electrical Engineering equipment see subchapter J. Existing Generator installations shall be tested to Satisfaction of an attending CG MI, barge crew needs tech assistance for generator testing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 27 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2024
Resolved
Piping systems and appurtenances not requiring plan approval may be accepted by the marine inspector if:
(a) The system is suitable for the service intended,
(b) There are guards, shields, insulation and similar devices where needed for protection of personnel. Portable fuel tank flex lines for generators need to be protected from mechanical damage where they cross walkways or otherwise subject to damage.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 27 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2024
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by § 91.45–1. The general scope of the plans shall be as noted in § 91.55–5. Added FOSS PAM, changed electrical installation, replaced generators not in kind. Obtain approved; barge electical one-line plan for the modified section, General Arrangement plan, FCP, & Sea Fastening plan that reflect new PAM and generator(s). The PAM installations has been insepcted to plans as submitted.New Generator one-line has not been submitted, generator testing is covered by seperate 835.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 31 May 2024
Navigation
Issued 9 March 2001
Resolved
INSTALL NAVIGATION LIGHTS MEETING UL 1104 AS PER SUBCHAPTER J.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001