MAURY USCG vessel records
← All vessels

GUADALUPE

GUADALUPE is a 2005 freight ship. The Coast Guard has recorded 53 inspections since 2016, most recently in February 2026, along with 28 deficiencies and 6 operational controls.

Records from 2016 to 2026. Most recent: inspection, 17 February 2026.

Built
2005
Last inspected
17 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9330941
1199453
Flag
CYPRUS
Maury page id
psix-1199453

Documentation record

Tonnage as PSIX records it1314 - Convention (Subpart B), Net Ton
4716 - Dead Weight, Ton
6598 - Displacement, Metric Ton
1314 - Regulatory (Subpart C or D), Gross Ton
2978 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 53

17 February 2026 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8309483
3 February 2026 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8302814
1 August 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8190893
19 July 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8190724
9 June 2025 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8155452
2 June 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8149613
26 May 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8144298
18 May 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8138395
13 May 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8135019
27 April 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8120771
23 April 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8117591
15 April 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8111942
7 April 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8106540
27 January 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8070336
7 July 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7950004
24 June 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7941277
12 June 2024 PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7930980
30 April 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7903895
15 April 2024 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7895579
26 January 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7856066
4 December 2023 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7832141
9 June 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7706411
2 February 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631314
5 December 2022 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7602415
7 June 2022 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7470844
21 March 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7415878
19 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7382379
9 January 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7401074
3 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374999
6 December 2021 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361708
20 September 2021 PSC C
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7316224
13 August 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7285679
21 June 2021 Ballast Water Examination · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7231417
16 June 2021 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7227525
29 April 2021 Ballast Water Examination · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7185368
20 April 2021 PSC B · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7178863
2 March 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7149088
8 January 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7121580
21 December 2020 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7113730
10 December 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6870506
11 April 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6660546
13 November 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6579476
28 September 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6550689
4 June 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6434071
29 May 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6437716
25 May 2018 PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6421462
16 May 2018 ISPS III Exam · Ballast Water Examination · Deficiency Check · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6415079
29 January 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6345533
15 October 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6286882
8 October 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6283571
15 December 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6058078
4 October 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6016731
1 August 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5959117

Deficiency record · 28

09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 17 February 2026 Resolved
09206-Satisfactory means for safe passage required by regulation 25-1 shall be provided for the protection of the crew in getting to and from any other spaces used in essential operation of the ship. PSCO observed no satisfactory protection for crew from falling into cargo hold nr.1. ICLL 1966 25.4, Annex I/16AC
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2026
Resolved 27 February 2026
Resolution: Stanchions and chain lins were put into place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 February 2026 Resolved
13199-The machinery and fitting shall be of a design and construction adequate for the service for which they are intended. PSCO observed a temporary zip tie repair on Nr.3 fuel oil purifier water cooling line. 74SOLAS(97) II-1/26.1/16AC
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2026
Resolved 27 February 2026
Resolution: Fuel oil purifier water cooling line was repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 February 2026 Resolved
07199-Cylinders must always be secured and be stowed,and in rack in an upright position,with the valve protection cap in place. PSCO observed that the required valve protection cap was missing on 01 cylinders. 46CFR147.60(b) /16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2026
Resolved 17 February 2026
Resolution: Valve protection cap was placed on the cylinder and platform has been provided for the remaining cylinders.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 February 2026 Resolved
07106 - The function of the detection system shall be by means of equipment producing the phenomena associated with incipient fires to which the detector is designed to respond. PSCO observed inappropiate means of testing of flame detectors. 74SOLAS(97) II-2/13.1.13/50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2026
Resolved 29 March 2026
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 3 February 2026 Resolved
Two sets of steel ladders as widely seperated as possible leading to doors in the upper part of the space similarly seperated and from which access is provided to the open deck in general, one of these ladders shall provide continuous fire shelter from the lower part of the space. PSCO observed an opening cut in the bulkhead of the emergency escape trunk leading from the main engineering space, allowing free movment of both smoke and flame. 74 SOLAS(97) II-2/45.3.1 17AC
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2026
Resolution: Crew welded a doubler plate over the opening.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 February 2026 Resolved
Hydraulic power-operated steering gear shall be provided with the following: A fixed storage tank having sufficient capicity to recharge at least one power actuating system including the reservouir. PSCO observed empty hydraulic oil reservoir. 74SOLAS(97)II-2/29.12.3 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2026
Resolution: Crew filled the reservoir.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2026 Resolved
All waste receptacles shall be constructed of non-combustable materials with no openings in the sides or bottom. PSCO observed combustable waste recepticales throughout the ship. 74SOLAS(97)II-2/18.5 40AC
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 February 2026
Resolution: The deficiency has been rectified by the crew. All combustible waste receptacles have been replaced with non-combustible ones.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 February 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed fuel shut off valve failing to close when initially activated for the emergency generator. 74SOLAS(20)I/11 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 February 2026
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 August 2025 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained and ready for use. PSCO observed 04 manually operated call points covered with clear tape. 74 SOLAS (97 CONS) Ch. II-2 Reg 2.2.7
Action required: 10 - Deficiency Rectified
Resolved 1 August 2025
Resolution: removed clear tape
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 27 January 2025 Resolved
THE OIL RECORD BOOK PART I SHALL BE COMPLETED ON EACH OCCASION, ON A TANK-TO-TANK BASIS IF APPROPRIATE WHENEVER ANY OF THE FOLLOWING MACHINERY SPACE OPERATIONS TAKES PLACE IN THE SHIP: COLLECTION AND DISPOSAL OF OIL RESIDUES (SLUDGE). DISCHARGE OF OILY WATER ON 21MAY24 WAS NOT LOGGED IN THE OIL RECORD BOOK. MARPOL I/REG.17.2.3 Code: 10c
Action required: 10 - Deficiency Rectified
Due 27 January 2025
Resolved 27 January 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 June 2024 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO's observed 43 out of 54 total CO2 cylinders with cotter pins installed at the top-valve location on the cylinder head. Per the manufacturer's instructions, the presence of the cotter pins renders the cylinders inoperable. the cotter pins were installed into the top-valves on 22MAY2024 as a safety precaution while conducting cleaning, and the pins were inadvertently not removed, rendering the system not ready for immediate use for a total of 22 days. 74 SOLAS (97) Ch II-2/21
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 June 2024
Resolution: Conducted def check. Verified cylinders arranged per survey report and manufacturer's instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 20 April 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2021
Resolution: Receieved Class Report (attached) attesting to the vessel receiving the missing items in the lifeboat.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 April 2021 Resolved
Where the emergency source of electrical powe is a generator, it shall be started automatically upon failure of the main source. PSCO observed fuel cut off valve engaged when inspecting emergency generator. Crew reset valve on the spot, emergency generator able to start afterwards. 74 SOLAS (04) II-1/43.3.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 April 2021
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 20 April 2021 Resolved
07111 - A firearms outfit shall consist of items listed under II-2/17.1.1. PSCO observed firefighter outfit on bridge to be missing: gloves, torch, lifeline, and hatchet. The missing items were in a separate box labeled “training” not in accordance with Fire Control Plan. Crew moved equipment to correct location before PSCO left vessel. 74SOLAS(97)II-2/17.1 10c.
Action required: 10 - Deficiency Rectified
Resolved 20 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021 Resolved
99101 - A Ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: “Discharge of Oil Prohibited…” PSCO observed no placarding required by 33CFR155.450(a) in engine room. 33CFR155.450(a) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2021
Resolution: Class Report showing multiple placards put in place.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 April 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 July 2021
Resolved 16 June 2021
Resolution: Received internal audit report and class approval of proposed preventive actions.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 16 May 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 30 - Ship detained
Resolved 18 May 2018
Resolution: ISM Audit conducted by DNV-GL auditor. 04 Non conformities identified.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 May 2018 Resolved
02-2035- IN ALL SHIPS GENERAL ARRANGEMENT PLANS SHALL BE PERMANENTLY EXHIBITED FOR THE GUIDANCE OF THE SHIP'S OFFICERS SHOWING CLEARLY FOR EACH DECK THE CONTROL STATIONS, THE VARIOUS FIRE SECTIONS ENCLOSED BY "A" CLASS DIVISIONS, THE SECTIONS ENCLOSED BY "B" CLASS DIVISIONS TOGETHER WITH PARTICULARS OF THE FIRE DETECTION AND FIRE ALARM SYSTEMS, THE SPRINKLER INSTALLATION, THE FIRE EXTINGUISHING APPLIANCES, MEANS OF ACCESS TO DIFFERENT COMPARTMENTS, DECKS, ETC. PSCO OBSERVED CLASS "A" FIRE DOORS LOCATED IN THE FORECASTLE, STEERING GEAR ROOM AND GALLEY, INDICATED AS SELF CLOSING ON THE FIRE CONTROL PLAN, SECURED OPEN USING HOLD BACKS AND WOODEN WEDGES. ADDITIONALLY, THE CLASS "A"FIRE DOOR LOCATED IN THE FORECASTLE WAS MISSING THE COMPLETE DOOR HANDLE ASSEMBLY. 74SOLAS (97CONS) CH II-2 / REG 20.1 30ABC
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 18 May 2018
Resolution: All fire doors fixed and inspected by class surveyor and PSCO.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 May 2018 Resolved
05-0720- FIRE EXTINGUISHERS SHALL BE PERIODICALLY EXAMINED AND SUBJECTED TO SUCH TESTS AS THE ADMINISTRATION MAY REQUIRE. PSCO OBSERVED 20 FIRE EXTINGUISHERS NOT SERVICED IN ACCORDANCE WITH ONBOARD PROCEDURES. PSCO OBSERVED 20 TOTAL SPARE FIRE EXTINGUISHERS LOCATED IN THE AFT STORAGE COMPARTMENT, 19 HAD NOT BEEN INSPECTED SINCE FEBRUARY 2018. FIRE EXTINGUISHERS LOCATED IN THE EMERGENCY GENERATOR COMPARTMENT, ENGINE ROOM LOWER LEVEL ON THE STARBOARD SIDE, AND ENGINEN ROOM NEAR THE FUEL OIL AND LUBE OIL PURIFIERS HAD NOT BEEN INSPECTED IN THE MONTH OF APRIL. ADDITIONALLY, THE EXTINGUISHER LOCATED IN THE RESCUE BOAT HAD NOT BEEN INSPECTED SINCE DECEMBER 2017. EVERY OTHER FIRE EXTINGUISHER CHECKED BY PSCOS HAD TAGS INDICATING A MONTHLY INSPECTION HAD BEEN CONDUCTED. 74SOLAS(97 CONS) CH II-2/REG 6.5 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2018
Resolution: Identified as a non conformity. Fire extinguishers all up to date.
Fire Fighting › Fire Hoses › Condition
Issued 16 May 2018 Resolved
06-0720- FIRE HOSES SHALL BE KEPT READY FOR USE IN CONSPICUOUS POSITIONS NEAR THE WATER SERVICE HYDRANTS AND CONNECTIONS. PSCO OBSERVED 02 FIRE HOSE BOXES ON THE PORT SIDE TIED SHUT WITH NYLON LINE THAT TOOK APPROXIMATELY 03 MINUTES TO UNTIE, WHICH GAINS ACCESS TO THE FIRE HOSE, FIRE HOSE NOZZLE, AND SPANNER WRENCH. THIS WAS DUE TO THE LATCHES BEING BROKEN ON THE FIRE BOXES. 74SOLAS(97 CONS) CH II-2/REG 20.2 17AC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2018
Resolution: Fire boxes are now repaired.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 May 2018 Resolved
07-2035- IN ALL SHIPS A DUPLICATE SET OF FIRE CONTROL PLANS OR A BOOKLET CONTAINING SUCH PLANS SHALL BE PERMANENTLY STORED IN A PROMINENTLY MARKED WEATHER TIGHT ENCLOSURE OUTSIDE THE DECK HOUSE FOR THE ASSISTANCE OF SHORE SIDE FIRE FIGHTING PERSONNEL. PSCO OBSERVED DUPLICATE SET OF FIRE CONTROL PLAN SEIZED SHUT IN WEATHER TIGHT CONTAINER, UNACCESSABLE TO PERSONNEL. 74SOLAS(97 CONS) CH II-2/REG 20.2 17AC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2018
Resolution: Water tight container fixed. Fire plan is now accessable.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 May 2018 Resolved
03-0925- CREW MEMBERS WITH ENCLOSED SPACE ENTRY OR RESCUE RESPONSIBILITIES SHALL PARTICIPATE IN AN ENCLOSED SPACE ENTRY AND RESCUE DRILL TO BE HELD ONBOARD THE SHIP AT LEAST ONCE EVERY TWO MONTHS. THE VESSEL WAS NOT CONDUCTING ENCLOSED SPACE ENTRY AND RESCUE DRILLS AS REQUIRED. 74SOLAS(14 CONS) CH III/REG 19.3.3 30 ABC
Action required: 30 - Ship detained
Resolved 18 May 2018
Resolution: Enclosed space entry and rescue drill properly conducted on 16MAY18. Class allowed 03 months for SMS to be updated.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 May 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 30 - Ship detained
Resolved 18 May 2018
Resolution: Calibrated, new atmospheric testing instrument now on board.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 16 May 2018 Resolved
08-0616- THE NORMAL EQUIPMENT OF EVERY RESCUE BOAT SHALL CONSIST OF A SEARCHLIGHT. [name withheld] WHO IS IN CHARGE OF THE RESCUE BOAT DURING MAN OVERBOARD EVOLUTIONS. NEITHER THE [name withheld] COULD DEMONSTRATE PROPER OPERATION OF THE REQUIRED SEARCH LIGHT. 74SOLAS(97 CONS) CH III/REG 47.2.2.11 17AC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2018
Resolution: Proper operation of search light demonstrated. SMS being updated to specify tests that need to be conducted.
Personnel › Training › Proficiency in Survival Craft
Issued 16 May 2018 Resolved
09-2540- THE LEVEL OF KNOWLEDGE OF THE SUBJECTS LISTED IN COLUMN 2 OF TABLE A-VI/2-1 SHALL BE SUFFICIENT TO ENABLE THE CANDIDATE TO LAUNCH AND TAKE CHARGE OF A SURVIVAL CRAFT OR RESCUE BOAT IN EMERGENCY SITUATIONS. THE CREW WAS NOT ABLE TO PRACTICALLY DEMONSTRATE THE ABILITY TO USE SEARCHLIGHT. STCW A-VI/2 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2018
Resolution: [name withheld] trained on the requirements of operating equipment within the rescue boat.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 16 May 2018 Resolved
10-0899- THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED VESSEL BUNKER TRANSFER ELECTRICAL CONTROL PANEL ALARMS LOCATION ON AFT MAIN DECK SUBJECT TO ALL WEATHER CONDITIONS IDENTIFIED BOTH PORT AND STARBOARD ALARM PANELS WITH DAMAGED OR MISSING LEVEL INDICATOR LIGHTS. 74SOLAS(14CONS) CH 1 / REG 11(a) 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2018
Resolution: Devices are not required and were taken out of service.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 16 May 2018 Resolved
11-0899- THE TRANSFER PROCEDURES REQUIRED BY 33CFR155.720 MUST BE PERMANENTLY POSTED OR AVAILABLE AT A PLACE WHERE THE PROCEDURES CAN BE EASILY SEEN AND USED BY MEMBERS OF THE CREW WHEN ENGAGED IN TRANSFER OPERATIONS. PSCO OBSERVED DURING BUNKER OPERATIONS, THERE WERE NO TRANSFER PROCEDURES ON BOARD. 33CFR155.740(c) 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2018
Resolution: Transfer procedures provided and posted near bunker station.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 16 May 2018 Resolved
12-0899- NO PERSON SHALL CONDUCT AN OIL OR HAZARDOUS MATERIAL TRANSFER OPERATION UNLESS EACH DRAIN AND SCUPPER IS CLOSED BY THE MECHANICAL MEANS REQUIRED BY 33 CFR155.310. PSCO OBSERVED DURING OPERATIONS THAT SCUPPERS WERE CLOSED BYA A WOODEN WEDGE. 33CFR156.120(O) 17C
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 June 2018
Resolution: VESSEL PURCHASED NEW MECHANICAL DRAIN PLUGS AND REPLACED EXISTING WOOD CHOCKS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.