MAURY USCG vessel records
← All vessels

MISS SOPHIE

MISS SOPHIE is a 2012 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in April 2026, along with 5 deficiencies and 2 casualty investigations between 2016 and 2024.

Records from 2016 to 2026. Most recent: inspection, 21 April 2026.

Built
2012
Last inspected
21 April 2026
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN5240
1199642
Flag
UNITED STATES
Maury page id
psix-1199642

Documentation record

Registered dimensions (L × B × D)38.0 ft × 13.5 ft × 5.5 ft
Registered tonnagegross 18 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCURTIS MARINE OF NEW YORK · SETAUKET, NY, UNITED STATES · built 2012
Hull materialAluminum
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portNATIONAL HARBOR, MD
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Net Ton
18 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

21 April 2026 Deficiency Check · Annual Inspection · Vessel Attendance
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8340705
6 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8340887
20 January 2026 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8298538
17 April 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8104560
20 July 2024 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7962612
20 July 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7979761
13 December 2023 COI Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7824641
19 December 2022 COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7607921
16 July 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7007991
25 February 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6913759
20 March 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6646472
28 May 2018 Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6426961
7 February 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6352684
8 November 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6314849
25 October 2016 DAPI Audit · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6029458
14 April 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5854210
14 April 2016 Damage Survey · Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5854423
25 March 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5840598
25 March 2016 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5846712

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 April 2026 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing for fixed-gas fire extinguishing systems to the marine inspector. At the time of inspection, the Fireboy system in the machinery space was past due for annual servicing. Technician is scheduled to attend on April 29th. Provide servicing report to attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 6 May 2026
Resolution: Received servicing report for fixed system. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2026 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Flex hose between raw water intake valve and sea strainer on port side engine was partially pinched and damaged. Replace hose to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 20 May 2026
Resolution: Raw water hoses were replaced with new ones.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Wet exhaust seal on port side engine has a slow water leak coming out the top of the seal. Replace to satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 20 May 2026
Resolution: Repair was made to the wet exhaust seal and is no longer leaking water. Ran port engine and verified no leaks.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2026 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Sea chests, sea valves, and sea strainers must be opened for examination. Vessel was not made available for examination. Hull was covered with marine growth, sea strainers were covered with barnacles, valves were unable to be inspected, outboard drive units will be replaced during this drydock, new units will need to be operationally tested prior to hull credit. Operator to re-schedule hull exam when all available items are available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2026
Resolved 6 April 2026
Resolution: Credit drydock conducted.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 4 April 2016 Resolved
Vessel had a fire on board in the engine space. With Subsequent flooding through the exhaust. Vessel is restricted from carring passangers until repairs are conducted and verified by attending Marine Inspector. Vessel to prove that it is fit to operate as certificated, provide repair proprosals to attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2016
Resolution: Vessel renewed all affected engine room components to satisfaction of attending [name withheld] ability to operate as certified through approved sea trials.

Casualty record · 2

25 March 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 5840598
20 July 2024Routine · role: Involved in a Marine Casualty · activity 7979761
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.