← All vessels
VIALLI
VIALLI is a 2012 tank ship. The Coast Guard has recorded 8 inspections since 2016, most recently in June 2023, along with 7 deficiencies and 3 operational controls.
Records from 2016 to 2023. Most recent: inspection, 25 June 2023.
- Built
- 2012
- Last inspected
- 25 June 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9538153 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V8232
1199964
Flag
LIBERIA
—
Maury page id
psix-1199964
Inspections, by type
…with no type recorded1
Years with a record
4 calendar years (2016–2023)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it52422 - Dead Weight, Metric Ton
64396 - Displacement, Metric Ton
15650 - Convention (Subpart B), Net Ton
30240 - Convention (Subpart B), Gross Ton
64396 - Displacement, Metric Ton
15650 - Convention (Subpart B), Net Ton
30240 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
25 June 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7718868
23 June 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7721745
9 September 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7555008
13 August 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7532164
21 March 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7412038
11 December 2018
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6592086
7 December 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6593938
6 December 2016
Ballast Water Examination · COE-Dockside · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6053305
Deficiency record · 7
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 March 2022
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL LEAKS ON NUMBER ONE AND NUMBER TWO GENERATORS ON MULTIPLE HIGH PRESSURE FUEL PUMPS. 74 SOLAS (20) II-2/4.1.1
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 21 March 2022
Resolved
THE INTERNATIONAL LOAD LINE CERTIFICATE SHALL NOT BE DELIVERED TO THE SHIP UNTIL THE OFFICER OR SURVEYOR ACTING UNDER THE PROVISIONS OF ARTICLE 13 OF THE PRESENT CONVENTION HAS CERTIFIED THAT THE MARKS ARE CORRECTLY AND PERMANENTLY INDICATED ON THE SHIP'S SIDES. PSCO OBSERVED ALL THREE LOAD LINES PAINTED ON PORT AND STARBOARD SIDE ALONG WITH DECK LINE NOT BEING PAINTED WITH CONTRASTING COLORS. ICLL ANNEX I REGUALTION 9
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 March 2022
Resolved
EACH VESSEL VAPOR CONNECTION FLANGE FACE MUST HAVE A PERMANENT STUD PROJECTING OUTWARD THAT HAS A 12.7 MM DIAMETER AND IS AT LEAST 25.4 MM LONG. IT MUST BE LOCATED AT THE TOP OF THE FLANGE FACE, MIDWAY BETWEEN BOLT HOLES, AND IN LINE WITH THE BOLT HOLE PATTERN. PSCO OBSERVED ALL VAPOR CONNECTION FLANGES MISSING THE PERMANENT STUD REQUIRED BY REGULATION. RECTIFY DEFICIENCY PRIOR TO LOADING CARGOS THAT REQUIRE VECS IN THE UNITED STATES. 46 CFR 39.2001(J)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 December 2018
Resolved
07114-Remote Means of Control-Oil fuel pipes which if damaged would allow oil to escape from a storage, settling or daily services tank having a capacity of 500 liters and above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed blocking devices in the remote quick closing valves on the fuel oil service tank and diesel oil service tanks. Records indicate last recorded testing of quick closing valves was November 20, 2018. Furthermore, company issued Live-Message No.23 addressing testing and the importance of ensuring quick closing valves are not blocked. 74 SOLAS (2014 CONS) II-2/4.2.2.3.4-30ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 December 2018
Resolved
13101-Propulsion Main Engine-The machinery, boiler, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed air leaking from the main engine VIT solenoid valve located on after portion of engine. SOLAS 74 (2014 Cons)II-1/26.1-60ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 December 2018
Resolved
15109-Maintenance of the ship and equipment- The company and the ship shall comply with the requirements of the International Safety Management Code. The company should establish procedures, plans and instructions, including checklists as appropriate, for the key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Vessel could not provide any checklist or procedure for the testing of quick closing valves. Provide corrective action plan from company with concurrence from Adminsitration. SOLAS (2014 Cons)IX/3.1 ISM Code Reg.7-16ac
Lifesaving › Inflatable Liferafts › Float Free
Issued 6 December 2016
Resolved
0628 - Stowage of Liferafts - Each liferaft shall be stowed with a float-free arrangement complying with the req. of par. 4.1.6 of the LSA Code so that each floats free and, if inflatable, inflates automatically when the ship sinks. PSCO observed that both liferafts on the port side were installed so that they would not auto. inflate in the case of the ship sinking. 74 SOLAS (09) III/13.4.2 10(c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.