ELITE FAITH is a 2008 public freight. The Coast Guard has recorded 4 inspections since 2020, most recently in December 2024, along with 23 deficiencies and 1 operational control.

Records from 2020 to 2024. Most recent: inspection, 7 December 2024.

Built
2008
Last inspected
7 December 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9454058
HP5457
1202985
Flag
PANAMA
Maury page id
psix-1202985

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 3 calendar years (2020–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it3217 - Convention (Subpart B), Net Ton
7460 - Convention (Subpart B), Gross Ton
91059 - Dead Weight, Ton
12901 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

7 December 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064125
3 December 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8042826
24 December 2021 PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7372174
17 December 2020 Ballast Water Examination · MARPOL Annex I Examination · Deficiency Check · PSC A · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7110370

Deficiency record · 23

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 4 February 2021 Resolved
13199- OTHER MACHINERY-All steering gear component and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. Steering Gear hunted 3 degrees port and stbd. SOLAS 74 (09) II-2/4.1.1
Action required: 10 - Deficiency Rectified
Due 4 February 2021
Resolved 4 February 2021
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 4 February 2021 Resolved
08104 –STEERING GEAR ALARMS- AUDIBLE AND VISIUAL ALARMS SHALL BE GIVEN ON THE NAVIGATION BRIDGE FOR LOW LEVEL HYDRAULIC FLUID. NO AUDIBLE ALARM WAS GIVEN ON THE BRIDGE. VESSEL CHANGED NAMES OWER ON THE 02 JAN 2021. NEW OWNER IS D&C OCEAN SHIPPING., LIMITED THE ONLY REMAINING DEF NEEDS TO BE VERIFIED WILL THE VESSEL IS UNDER WAY. DUE DATE WAS CHANGE TO FIRST U.S PORT AFTER SAILING FOREIGN.
Action required: 10 - Deficiency Rectified
Due 4 February 2021
Resolved 4 February 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 January 2021 Resolved
MEANS OF CONTROL FOR THE AIR SUPPLY TO THE SPACE SHALL BE PROVIDED. PSCO OBSERVED WASTED AND HOLES IN THE VENTILATION AFT OF THE DAMPENERS IN THE A/C COMPRESSOR ROOM AND IN THE ENGINE ROOM. 74 SOLAS (09) 5.1.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 7 January 2021 Resolved
CONDITION OF THE SHIP ITS EQUIPMENT SHALL MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION. PSCO OBSERVED THAT SLUDGE, BILGE AND DRAIN TRAY FOR SSDG LINES WERE CUT AND MODIFIED WITH TEMPORARY HOSE ARRANGEMENTS. ANNEX I/6.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2021 Resolved
AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED NO CHANGES SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS MACHINERY AND OTHER ITEM COVERED BY THE SURVEY WITHOUT THE SANCTION OF THE ADMINISTRATION. VESSELS’ CREW MODIFIED A HANDLE FOR THE GOVERNOR ON THE MAIN ENGINE. SOLAS (09) I/11
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 January 2021 Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION OF WHICH THEY ARE FITTING. AN A-60 DOOR LOCATED ON THE MAIN DECK LEADING FORM THE ACCOMMODATION TO THE ENGINEERING SPACE HAD A 4 INCH CRACK IN THE DOOR. SOLAS 74 (09) II-2/9.4.2.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 December 2020 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING EQUIPMENT APPLIANCES SHALL BE READY FOR IMMEDIATE USE. PSCO FOUND PORT AND STBD LIFE RAFTS TIED DOWN PREVENTING FLOAT FREE ARRANGEMENTS. THE COVER FOR DAVIT LIFE RAFT SLING WAS COMPROMISED EXPOSING THE RAFT TO THE ELEMENTS. 6-MAN FORWARD LIFERAFT SHELL WAS CRACKED EXPOSING THE RAFT TO THE ELEMENTS. MARKINGS REQUIRED BY THE LSA CODE WERE MISSING ON THE LIFERAFT CONTAINERS INCLUDING LENGTH OF PAINTER, AND MAXIMUM PERMITTED STOWAGE HEIGHT. DISCREPANCIES IDENTIFIED IN THE PACKING/SERVICING OF LIFERAFTS. STERN LAUNCH LIFEBOAT MISSING SEAT RESTRAINT.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 December 2020 Resolved
ANY REQUIRED AUTOMATIC SPRINKLER SYSTEM SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES AND NO ACTION BY THE CREW SHALL BE NECESSARY TO SET IT IN OPERATION. SYSTEM WAS FOUND IN MANUAL OPERATION RENDERING SYSTEM NOT ABLE TO START AUTOMATICALLY AS REQUIRED.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 December 2020 Resolved
SHIPS SHALL BE PROVIDED WITH FIRE PUMPS, FIRE MAINS, HYDRANTS, AND HOSES COMPLYING WITH THE APPLICABLE REQUIREMENTS OF REGULATION 10. PSCO OBSERVED 25 MINUTE DELAY IN DELIVERY OF WATER TO THE HYDRANT AFTER STARTING FIRE PUMP. DOUBLER WAS FOUND PORT SIDE FWD OF THE HOUSE ON FIREMAIN. LEAKS WERE OBSERVED ON HYDRANTS AND PIPING. GENERAL SERVICE AND EMERGENCY FIRE PUMP WIRING TO MOTOR HAD CONDUCTORS NOT INSULATED AND STRAIN RELIEF WAS NOT PROVIDED TO CONDUCTORS.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 December 2020 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. DIESEL OIL LEAKS WERE OBSERVED ON BULKHEAD FITTINGS FROM STORAGE TANKS INTO ENGINE ROOM. LEAK WAS OBSERVED AT 1 DRIP/2 SECONDS. ADDITIONAL LEAKS WERE OBSERVED ON FUEL OIL PIPING UNDER PURIFIERS.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 December 2020 Resolved
THE CONSTRUCTION AND THE MEANS FOR SECURING THE WEATHERTIGHTNESS OF CARGO AND OTHER HATCHWAYS IN POSITIONS 1 & 2 SHALL BE AT LEAST EQUIVALENT TO THE REQUIREMENTS OF 15 & 16 OF ANNEX I. HATCH COVERS WERE FOUND WITH MODIFICATIONS/UNAUTHORIZED REPAIRS. SOUNDING TUBES FOR VOIDS AND BALLAST TANKS WERE MISSING CAPS ALLOWING DOWNFLOODING. VENTILATOR HATCH COVERS WERE SEVERELY WASTED PREVENTING PROPER CLOSURE. ANCHOR WASH WAS HOLED, ALLOWING WATER INTO BOSN STORE.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2020 Resolved
MAIN SOURCE OF ELECTRICAL POWER OF SUFFICIENT CAPACITY TO SUPPLY ALL THOSE SERVICES MENTIONED IN REGULATION 40.1.1 SHALL BE PROVIDED. MACHINERY AND ASSOCIATED PIPING SYSTEMS SHALL BE MADE OF ADEQUATE DESIGN AND CONSTRUCTION. PSCO OBSERVED LEAKS ON #1 AND #2 GENERATOR SALTWATER INLET PIPES IN WAY OF TEMPORARY REPAIRS PRESENTING POSSIBILITY OF OVERHEATING AND LOSS OF 2 OUT OF 3 GENERATORS.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 December 2020 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE READILY AVAILABLE FOR IMMEDIATE USE. EXTINGUISHERS WERE LOCATED IN SUCH A POSITION THAT ACCESS IS LIMITED AND INHIBITED BY THE BALLAST WATER TREATMENT SYSTEM. PSCO OBSERVED LIMITED ACCESS TO FIRESUITS LOCATED AT MAIN DECK STAIRWELL. FOAM APPLICATOR AND CONTAINERS IN UPPER LEVEL ENGINE ROOM BY BOILER WERE STORED IN A POSITION NOT AVAILABLE FOR IMMEDIATE USE.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 December 2020 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. LIFEJACKETS AND IMMERSION SUITS FOR 6-MAN LIFERAFT IN BOSN STORE WERE STORED IN A MANNER NOT READY FOR IMMEDIATE USE.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 December 2020 Resolved
INTERNAL COMBUSTION ENGINES OF A CYLINDER DIAMETER OF 200MM OR A CRANKCASE VOLUME OF 0.6 CUBIC METERS SHALL BE PROVIDED WITH CRANKCASE EXPLOSION RELIEF VALVES. ALL CRANKCASE EXPLOSION COVERS WERE EXCESSIVELY COATED WITH PAINT PREVENTING PROPER FUNCTION IN EVENT OF CRANKCASE EXPLOSION.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 December 2020 Resolved
MACHINERY AND ASSOCIATED FITTINGS SHALL BE DESIGNED AND INSTALLED AS INTENDED TO REDUCE DANGERS TO PERSONS ONBOARD. PSCO OBSERVED ALL SHIPS SERVICE DIESEL GENERATORS, AND OWS BILGE PUMP MISSING MACHINERY GUARDS PRESENTING HAZARD TO CREW.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2020 Resolved
MAIN SOURCE OF ELECTRICAL POWER OF SUFFICIENT CAPACITY TO SUPPLY ALL SERVICES SHALL CONSIST OF AT LEAST 2 GENERATING SETS. MACHINERY AND ASSOCIATED PIPING SYSTEMS SHALL BE MADE OF ADEQUATE DESIGN AND CONSTRUCTION. THE FUEL SUPPLY SYSTEM PANEL FOR GENERATORS IS NOT FUNCTIONING AS DESIGNED. SEVERAL GAUGES AND SWITCHES WERE DISABLED AND RENDERED INOPERABLE POTENTIALLY LEADING TO UNNOTICED GENERATOR FUEL SERVICE TANK LOSS.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 December 2020 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. TANK TOPS FOR #2 SLUDGE TANK AND BILGE WATER HOLDING TANK WERE NOT BOLTED. TANK TOP BOLTS WERE REPORTED REMOVED IN OCTOBER 2020. NO BOLTS WERE PRESENT AND COVERS WERE NOT SECURED. FUEL LEAKS ACCUMULATING IN BILGE ARE DISPOSED IN SLUDGE TANK.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2020 Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION OF WHICH THEY ARE FITTING. SELF-CLOSING A-60 FIREDOOR IN LOWER LEVEL ENGINE ROOM FOR EMERGENCY ESCAPE FAILED TO SELF CLOSE AND IS DAMAGED. A-60 SELF-CLOSING FIRE DOOR ON DECK C LADDERWELL DID NOT SELF-CLOSE AS REQUIRED. A-15 DOOR FOR GALLEY FOUND DAMAGED AND INEFFECTIVE.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 17 December 2020 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS. BASED ON THE OVERALL MATERIEL CONDITION OF THE VESSEL AS SUBSTANTIATED BY THE OBJECTIVE EVIDENCE CITED ABOVE, AN ADDITIONAL EXTERNAL VERIFICATION IS RECOMMENDED.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 4 February 2021
Resolution: received class audit. see documents
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 December 2020 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READY FOR IMMEDIATE USE. CO2 SYSTEM HOSE WAS CHAFED AND STRAINED. GAUGE FOR CO2 DISCHARGE WAS INSTALLED PREVENTING OPERATOR FROM VIEWING GAUGE.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND INSTALLED AND PROTECTED TO MINIMIZE ANY DANGER TO PERSONS ON BOARD, DUE REGARD TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. CLAD WELD WAS IDENTIFIED ON HIGH PRESSURE FUEL PUMP FOR MAIN DIESEL ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Received class report showing that def. was cleared to the satisfaction of class, USCG also verified that repairs were completed. See class report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 December 2020 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. DIESEL OIL LEAKS WERE OBSERVED ON BULKHEAD FITTINGS FROM STORAGE TANKS INTO ENGINE ROOM. LEAK WAS OBSERVED AT 1 DRIP/2 SECONDS. ADDITIONAL LEAKS WERE OBSERVED ON FUEL OIL PIPING UNDER PURIFIERS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 September 2023
Resolution: Received class report showing fix.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.