MAURY USCG vessel records
← All vessels

FUGA

FUGA is a 2012 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in July 2025, along with 5 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 1 July 2025.

Built
2012
Last inspected
1 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9624615
1203116
Flag
PANAMA
Maury page id
psix-1203116

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it12134 - Convention (Subpart B), Net Ton
38036 - Dead Weight, Metric Ton
46324 - Displacement, Metric Ton
23264 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

1 July 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8172619
15 July 2024 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7940527
17 August 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7520242
29 May 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6697977
4 August 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5957424

Deficiency record · 5

Lifesaving › Lifeboat Equipment › Food Ration
Issued 4 August 2016 Resolved
0611 - Lifeboat equipment - PSCO observed in the port and starboard 25-person lifeboats that 3 and 2 food rations, respectively, were not kept in airtight packaging. 74 SOLAS (Am.) III/34. LSA Code 4.4.8.12. 17c.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2016
Resolved 6 August 2016
Resolution: Provided receipt and photo of new food rations.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 4 August 2016 Resolved
1705 - SOPEP missing or deficient - PSCO observed that only 4 rubber boots were stored in the SOPEP locker, while the approved SOPEP requires that 6 rubber boots be stored in the locker. Crew located the missing boots and returned them to the locker prior to the conclusion of the examination. MARPOL I/37.1. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 August 2016 Resolved
0699 - Other (Life Saving Appliances) - PSCO observed that life jacket donning instructions were missing from both the port and starboard muster stations. Crew located and posted the instructions prior to the conclusion of the examination. 74 SOLAS (Am.) III/8.4.3. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 August 2016 Resolved
PSCO observed that the light bulb for the emergency light at the starboard muster station was inoperable. Crew replaced the light bulb and PSCO confirmed its proper operation prior to the conclusion of the examination. 74 SOLAS (Am.) II-1/43.2.1. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 4 August 2016 Resolved
0715 - Detection - PSCO observed that the crew initially attempted to test a smoke detector using a cigarette lighter. Upon further analysis of the smoke detector's manufacturer's instruction, the crew successfully tested the smoke detector using an approved smoke can method. 74 SOLAS (Am.) II-2/7.2.2. FSS Code 9.2.5.2. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.

Ownership record