Records from 2016 to 2025. Most recent: inspection, 1 July 2025.
Inspection history · 5
1 July 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8172619
15 July 2024
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7940527
17 August 2022
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7520242
29 May 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6697977
4 August 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5957424
Lifesaving › Lifeboat Equipment › Food Ration
Issued 4 August 2016
Resolved
0611 - Lifeboat equipment - PSCO observed in the port and starboard 25-person lifeboats that 3 and 2 food rations, respectively, were not kept in airtight packaging. 74 SOLAS (Am.) III/34. LSA Code 4.4.8.12. 17c.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2016
Resolved 6 August 2016
Resolution: Provided receipt and photo of new food rations.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 4 August 2016
Resolved
1705 - SOPEP missing or deficient - PSCO observed that only 4 rubber boots were stored in the SOPEP locker, while the approved SOPEP requires that 6 rubber boots be stored in the locker. Crew located the missing boots and returned them to the locker prior to the conclusion of the examination. MARPOL I/37.1. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 August 2016
Resolved
0699 - Other (Life Saving Appliances) - PSCO observed that life jacket donning instructions were missing from both the port and starboard muster stations. Crew located and posted the instructions prior to the conclusion of the examination. 74 SOLAS (Am.) III/8.4.3. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 August 2016
Resolved
PSCO observed that the light bulb for the emergency light at the starboard muster station was inoperable. Crew replaced the light bulb and PSCO confirmed its proper operation prior to the conclusion of the examination. 74 SOLAS (Am.) II-1/43.2.1. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 4 August 2016
Resolved
0715 - Detection - PSCO observed that the crew initially attempted to test a smoke detector using a cigarette lighter. Upon further analysis of the smoke detector's manufacturer's instruction, the crew successfully tested the smoke detector using an approved smoke can method. 74 SOLAS (Am.) II-2/7.2.2. FSS Code 9.2.5.2. 10c.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: On the spot correction.